fkie_cve-2023-39479
Vulnerability from fkie_nvd
Published
2024-05-03 03:15
Modified
2025-08-12 14:56
Summary
Softing Secure Integration Server OPC UA Gateway Directory Creation Vulnerability. This vulnerability allows remote attackers to create directories on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of FileDirectory OPC UA Objects. The issue results from allowing unauthorized access to the filesystem. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20548.
Impacted products
Vendor Product Version
softing secure_integration_server 1.22.0.8686



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:softing:secure_integration_server:1.22.0.8686:*:*:*:*:*:*:*",
              "matchCriteriaId": "077021EA-93E0-45A3-8AFD-47AA6A8C494D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Softing Secure Integration Server OPC UA Gateway Directory Creation Vulnerability. This vulnerability allows remote attackers to create directories on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of FileDirectory OPC UA Objects. The issue results from allowing unauthorized access to the filesystem. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20548."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de creaci\u00f3n de directorio de puerta de enlace OPC UA del servidor de integraci\u00f3n segura de Softing. Esta vulnerabilidad permite a atacantes remotos crear directorios en las instalaciones afectadas de Softing Secure Integration Server. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe en el manejo de objetos FileDirectory OPC UA. El problema surge al permitir el acceso no autorizado al sistema de archivos. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto de la ra\u00edz. Era ZDI-CAN-20548."
    }
  ],
  "id": "CVE-2023-39479",
  "lastModified": "2025-08-12T14:56:54.777",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.6,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-05-03T03:15:14.290",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1061/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1061/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-552"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…