fkie_cve-2023-4518
Vulnerability from fkie_nvd
Published
2023-12-01 15:15
Modified
2024-11-21 08:35
Summary
A vulnerability exists in the input validation of the GOOSE messages where out of range values received and processed by the IED caused a reboot of the device. In order for an attacker to exploit the vulnerability, goose receiving blocks need to be configured.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C4B7DA8-BA72-48E5-9E21-33FB1881E952",
              "versionEndExcluding": "2.2.2.6",
              "versionStartIncluding": "2.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4949214C-03DE-489E-80E3-7DC4EFED7ACA",
              "versionEndExcluding": "2.2.3.7",
              "versionStartIncluding": "2.2.3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53D9E635-5BDA-4383-9FE5-4AFA4148A5E3",
              "versionEndExcluding": "2.2.4.4",
              "versionStartIncluding": "2.2.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64A83135-6909-4838-9429-1046CA824723",
              "versionEndExcluding": "2.2.5.6",
              "versionStartIncluding": "2.2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADA98332-543F-48A7-B63C-B39F679D47F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "612B2549-82F9-4B7F-BDBD-95A562BF1EAE",
              "versionEndExcluding": "2.2.4.4",
              "versionStartIncluding": "2.2.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC7C5065-1CEC-44DC-BF01-16FC02390583",
              "versionEndExcluding": "2.2.5.6",
              "versionStartIncluding": "2.2.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A406AD0-38C5-4C32-AA88-AA45EE97C315",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A74BD43-D925-483C-98F7-5F5C32D3B6F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C658029-20F4-411A-B1FE-B4E07D590775",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "264C95EE-756F-434E-9FA1-DC7878CEEF61",
              "versionEndExcluding": "2.2.5.6",
              "versionStartIncluding": "2.2.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB5C50F4-CF04-4C13-868A-F7ECE49DE01B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "7025C2A4-698E-408C-9567-8759B638AB90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E73E9D1A-1DFE-4B7C-81F1-0809071A3DDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability exists in the input validation of the GOOSE \nmessages where out of range values received and processed \nby the IED caused a reboot of the device. In order for an \nattacker to exploit the vulnerability, goose receiving blocks need \nto be configured."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad en la validaci\u00f3n de entrada de los mensajes GOOSE donde los valores fuera de rango recibidos y procesados por el IED provocaron un reinicio del dispositivo. Para que un atacante aproveche la vulnerabilidad, es necesario configurar los bloques receptores de ganso."
    }
  ],
  "id": "CVE-2023-4518",
  "lastModified": "2024-11-21T08:35:20.213",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "cybersecurity@hitachienergy.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-12-01T15:15:07.860",
  "references": [
    {
      "source": "cybersecurity@hitachienergy.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000170\u0026languageCode=en\u0026Preview=true"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000170\u0026languageCode=en\u0026Preview=true"
    }
  ],
  "sourceIdentifier": "cybersecurity@hitachienergy.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1284"
        }
      ],
      "source": "cybersecurity@hitachienergy.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1284"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…