fkie_cve-2024-2013
Vulnerability from fkie_nvd
Published
2024-06-11 14:15
Modified
2024-11-21 09:08
Severity ?
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Summary
An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server /
API Gateway component that if exploited allows attackers without
any access to interact with the services and the post-authentication
attack surface.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | foxman-un | r15a | |
hitachienergy | foxman-un | r15b | |
hitachienergy | foxman-un | r16a | |
hitachienergy | foxman-un | r16b | |
hitachienergy | unem | r15a | |
hitachienergy | unem | r15b | |
hitachienergy | unem | r15b | |
hitachienergy | unem | r16b | |
hitachienergy | unem | r16b |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:foxman-un:r15a:*:*:*:*:*:*:*", "matchCriteriaId": "A7593C74-2882-45D3-AB32-3A45E3AECAAE", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:foxman-un:r15b:pc4:*:*:*:*:*:*", "matchCriteriaId": "7BFAA55C-0815-4ACA-A649-F1F910411885", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:foxman-un:r16a:*:*:*:*:*:*:*", "matchCriteriaId": "7EE987B2-0620-44BB-AEA7-4E20CBE44822", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:foxman-un:r16b:pc2:*:*:*:*:*:*", "matchCriteriaId": "A2009AD7-6DF9-4DFC-B9F2-8632AC037A27", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:unem:r15a:*:*:*:*:*:*:*", "matchCriteriaId": "E78C9E5B-5876-4F15-A98A-359193287446", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:unem:r15b:pc4:*:*:*:*:*:*", "matchCriteriaId": "73AAF812-D503-4672-98A7-53C332317A30", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:unem:r15b:pc5:*:*:*:*:*:*", "matchCriteriaId": "3071C1DE-77EE-4B40-A382-19A97770D49B", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:unem:r16b:*:*:*:*:*:*:*", "matchCriteriaId": "ADA6755A-0553-4246-B462-7580B080FDEF", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:unem:r16b:pc2:*:*:*:*:*:*", "matchCriteriaId": "D83E9A04-633A-493B-BD7A-ED28B88A521D", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server /\nAPI Gateway component that if exploited allows attackers without \nany access to interact with the services and the post-authentication \nattack surface." }, { "lang": "es", "value": "Existe una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en el servidor FOXMAN-UN/UNEM componente API Gateway que, si se explota, permite a atacantes sin ning\u00fan acceso interactuar con los servicios y la superficie de ataque posterior a la autenticaci\u00f3n. " } ], "id": "CVE-2024-2013", "lastModified": "2024-11-21T09:08:48.677", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-06-11T14:15:11.503", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000201\u0026languageCode=en\u0026Preview=true" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-288" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…