fkie_cve-2024-21757
Vulnerability from fkie_nvd
Published
2024-08-13 16:15
Modified
2024-08-22 14:34
Summary
A unverified password change in Fortinet FortiManager versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, as well as Fortinet FortiAnalyzer versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, allows an attacker to modify admin passwords via the device configuration backup.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5275A3C-5468-424E-B3BB-897221D2B8D5",
              "versionEndExcluding": "7.0.11",
              "versionStartIncluding": "7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F3D28A9-5CFD-4838-9630-D6E09FB63CE1",
              "versionEndExcluding": "7.2.5",
              "versionStartIncluding": "7.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB15106A-8295-4A9E-B5C8-FA9654636B15",
              "versionEndExcluding": "7.4.2",
              "versionStartIncluding": "7.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B1EF673-5967-401E-98E3-B7A2B1BEF037",
              "versionEndExcluding": "7.0.11",
              "versionStartIncluding": "7.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4763E504-6974-42C5-B912-3E62A9CC312A",
              "versionEndExcluding": "7.2.5",
              "versionStartIncluding": "7.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83316FAF-C5DE-4603-B3B2-6796E2FAF1A8",
              "versionEndExcluding": "7.4.2",
              "versionStartIncluding": "7.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A unverified password change in Fortinet FortiManager versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, as well as Fortinet FortiAnalyzer versions 7.0.0 through 7.0.10, versions 7.2.0 through 7.2.4, and versions 7.4.0 through 7.4.1, allows an attacker to modify admin passwords via the device configuration backup."
    },
    {
      "lang": "es",
      "value": "Un cambio de contrase\u00f1a no verificado en Fortinet FortiManager versiones 7.0.0 a 7.0.10, versiones 7.2.0 a 7.2.4 y versiones 7.4.0 a 7.4.1, as\u00ed como Fortinet FortiAnalyzer versiones 7.0.0 a 7.0.10, versiones 7.2.0 a 7.2.4 y las versiones 7.4.0 a 7.4.1 permiten a un atacante modificar las contrase\u00f1as de administrador a trav\u00e9s de la copia de seguridad de la configuraci\u00f3n del dispositivo."
    }
  ],
  "id": "CVE-2024-21757",
  "lastModified": "2024-08-22T14:34:54.550",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 4.2,
        "source": "psirt@fortinet.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-08-13T16:15:08.637",
  "references": [
    {
      "source": "psirt@fortinet.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://fortiguard.fortinet.com/psirt/FG-IR-23-467"
    }
  ],
  "sourceIdentifier": "psirt@fortinet.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-620"
        }
      ],
      "source": "psirt@fortinet.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…