fkie_cve-2024-30613
Vulnerability from fkie_nvd
Published
2024-03-29 13:15
Modified
2025-04-08 15:27
Severity ?
Summary
Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function." }, { "lang": "es", "value": "Tenda AC15 v15.03.05.18 tiene una vulnerabilidad de desbordamiento de la regi\u00f3n stack de la memoria en el par\u00e1metro de tiempo de la funci\u00f3n setSmartPowerManagement." } ], "id": "CVE-2024-30613", "lastModified": "2025-04-08T15:27:30.520", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-03-29T13:15:15.820", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/setSmartPowerManagement.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/setSmartPowerManagement.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…