fkie_cve-2024-4872
Vulnerability from fkie_nvd
Published
2024-08-27 13:15
Modified
2024-10-30 15:31
Severity ?
9.9 (Critical) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability
an attacker must have a valid credential.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_pro_sys600 | 9.4 | |
hitachienergy | microscada_pro_sys600 | 9.4 | |
hitachienergy | microscada_pro_sys600 | 9.4 | |
hitachienergy | microscada_pro_sys600 | 9.4 | |
hitachienergy | microscada_pro_sys600 | 9.4 | |
hitachienergy | microscada_x_sys600 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf1:*:*:*:*:*:*", "matchCriteriaId": "0B90ED6E-68E4-4C14-B275-F44BAC1B9C5C", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf2:*:*:*:*:*:*", "matchCriteriaId": "196E08EA-807C-4B7B-981A-96D106AC328B", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf3:*:*:*:*:*:*", "matchCriteriaId": "680FAE83-9D7A-4AD9-AFBE-480FD105ADC9", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf4:*:*:*:*:*:*", "matchCriteriaId": "014C8428-8F88-4C3D-B9B1-87DE26867471", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf5:*:*:*:*:*:*", "matchCriteriaId": "06AFA271-0785-4526-B7DA-FA00672CC5B5", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEAAFA90-ACFF-47E2-A23D-728912D74B99", "versionEndExcluding": "10.6", "versionStartIncluding": "10.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability\nan attacker must have a valid credential." }, { "lang": "es", "value": "El producto no valida ninguna consulta sobre datos persistentes, lo que genera riesgo de ataques de inyecci\u00f3n." } ], "id": "CVE-2024-4872", "lastModified": "2024-10-30T15:31:41.743", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-08-27T13:15:05.890", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-943" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…