Summary
An improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability [CWE-78] in Fortinet FortiIsolator before version 2.4.6 allows a privileged attacker with super-admin profile and CLI access to execute unauthorized code via specifically crafted HTTP requests.
References
▶ | URL | Tags | |
---|---|---|---|
psirt@fortinet.com | https://fortiguard.fortinet.com/psirt/FG-IR-24-397 | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
fortinet | fortiisolator | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:fortinet:fortiisolator:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9293C91-E242-442D-AADA-9B6EE1D7874F", "versionEndExcluding": "2.4.7", "versionStartIncluding": "2.4.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) vulnerability [CWE-78] in Fortinet FortiIsolator before version 2.4.6 allows a privileged attacker with super-admin profile and CLI access to execute unauthorized code via specifically crafted HTTP requests." }, { "lang": "es", "value": "Una vulnerabilidad de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del SO (\u0027OS Command Injection\u0027) [CWE-78] en Fortinet FortiIsolator anterior a la versi\u00f3n 2.4.6 permite que un atacante privilegiado con perfil de s\u00faper administrador y acceso CLI ejecute c\u00f3digo no autorizado a trav\u00e9s de solicitudes HTTP espec\u00edficamente manipuladas." } ], "id": "CVE-2024-54024", "lastModified": "2025-07-23T16:02:34.480", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "psirt@fortinet.com", "type": "Secondary" } ] }, "published": "2025-04-08T14:15:32.303", "references": [ { "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-397" } ], "sourceIdentifier": "psirt@fortinet.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "psirt@fortinet.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…