fkie_cve-2025-20224
Vulnerability from fkie_nvd
Published
2025-08-14 17:15
Modified
2025-08-15 13:12
Summary
A vulnerability in the Internet Key Exchange Version 2 (IKEv2) module of Cisco Secure Firewall Adaptive Security Appliance (ASA) Software and Secure Firewall Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to trigger a memory leak, resulting in a denial of service (DoS) condition. This vulnerability is due to improper parsing of IKEv2 packets. An attacker could exploit this vulnerability by sending a continuous stream of crafted IKEv2 packets to an affected device. A successful exploit could allow the attacker to partially exhaust system memory, causing system instability like being unable to establish new IKEv2 VPN sessions. A manual reboot of the device is required to recover from this condition.
Impacted products
Vendor Product Version



{
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in the Internet Key Exchange Version 2 (IKEv2) module of Cisco Secure Firewall Adaptive Security Appliance (ASA) Software and Secure Firewall Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to trigger a memory leak, resulting in a denial of service (DoS) condition.\r\n\r This vulnerability is due to improper parsing of IKEv2 packets. An attacker could exploit this vulnerability by sending a continuous stream of crafted IKEv2 packets to an affected device. A successful exploit could allow the attacker to partially exhaust system memory, causing system instability like being unable to establish new IKEv2 VPN sessions. A manual reboot of the device is required to recover from this condition."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en el m\u00f3dulo Intercambio de Claves de Internet Versi\u00f3n 2 (IKEv2) del software Cisco Secure Firewall Adaptive Security Appliance (ASA) y del software Secure Firewall Threat Defense (FTD) podr\u00eda permitir que un atacante remoto no autenticado provoque una fuga de memoria, lo que resulta en una denegaci\u00f3n de servicio (DoS). Esta vulnerabilidad se debe a un an\u00e1lisis incorrecto de paquetes IKEv2. Un atacante podr\u00eda explotarla enviando un flujo continuo de paquetes IKEv2 manipulados a un dispositivo afectado. Una explotaci\u00f3n exitosa podr\u00eda permitir al atacante agotar parcialmente la memoria del sistema, lo que causar\u00eda inestabilidad, como la imposibilidad de establecer nuevas sesiones VPN IKEv2. Es necesario reiniciar el dispositivo manualmente para solucionar este problema."
    }
  ],
  "id": "CVE-2025-20224",
  "lastModified": "2025-08-15T13:12:51.217",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 5.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "psirt@cisco.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2025-08-14T17:15:36.510",
  "references": [
    {
      "source": "psirt@cisco.com",
      "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-asa-ftd-ios-dos-DOESHWHy"
    }
  ],
  "sourceIdentifier": "psirt@cisco.com",
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ],
      "source": "psirt@cisco.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…