fkie_cve-2025-3498
Vulnerability from fkie_nvd
Published
2025-07-09 09:15
Modified
2025-07-10 13:17
Severity ?
Summary
An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).
Impacted products
Vendor Product Version



{
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unauthenticated user with management network access can get and \nmodify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) \nconfiguration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP\nports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration\nand execute some commands (e.g., system reboot)."
    },
    {
      "lang": "es",
      "value": "Un usuario no autenticado con acceso a la red de administraci\u00f3n puede obtener y modificar la configuraci\u00f3n de Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20). El dispositivo cuenta con dos servidores web que exponen API REST no autenticadas en la red de administraci\u00f3n (puertos TCP 8084 y 8086). Un atacante puede usar estas API para acceder a toda la configuraci\u00f3n del sistema, modificar la configuraci\u00f3n y ejecutar algunos comandos (p. ej., reiniciar el sistema)."
    }
  ],
  "id": "CVE-2025-3498",
  "lastModified": "2025-07-10T13:17:30.017",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 9.9,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.3,
        "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-09T09:15:27.137",
  "references": [
    {
      "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
      "url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2025-3498"
    }
  ],
  "sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…