fkie_cve-2025-36600
Vulnerability from fkie_nvd
Published
2025-07-08 15:15
Modified
2025-08-18 18:55
Summary
Dell Client Platform BIOS contains an Improper Access Control Applied to Mirrored or Aliased Memory Regions vulnerability in an externally developed component. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:latitude_12_rugged_extreme_7214_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65186F2F-55D7-447E-B16A-84E943D08A2A",
              "versionEndExcluding": "1.51.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dell:latitude_12_rugged_extreme_7214:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCD30F80-7517-4255-872F-558ABC9C3CE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell Client Platform BIOS contains an Improper Access Control Applied to Mirrored or Aliased Memory Regions vulnerability in an externally developed component. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution."
    },
    {
      "lang": "es",
      "value": "Dell Client Platform BIOS contiene una vulnerabilidad de control de acceso inadecuado aplicado a regiones de memoria duplicadas o con alias en un componente desarrollado externamente. Un atacante con privilegios elevados y acceso local podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda la ejecuci\u00f3n de c\u00f3digo."
    }
  ],
  "id": "CVE-2025-36600",
  "lastModified": "2025-08-18T18:55:09.460",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.5,
        "impactScore": 6.0,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-08T15:15:27.403",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000320876/dsa-2025-205"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1257"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…