Summary
Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
Impacted products
Vendor Product Version



{
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. \n\nThis issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025"
    },
    {
      "lang": "es",
      "value": "Medtronic MyCareLink Patient Monitor cuenta con un servicio interno que deserializa datos, lo que permite a un atacante local interactuar con el servicio mediante la manipulado de una carga binaria para bloquearlo o elevar privilegios. Este problema afecta a los modelos 24950 y 24952 de Medtronic MyCareLink Patient Monitor antes del 25 de junio de 2025."
    }
  ],
  "id": "CVE-2025-4393",
  "lastModified": "2025-07-25T15:29:44.523",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.0,
        "impactScore": 5.5,
        "source": "security@medtronic.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-24T07:15:53.343",
  "references": [
    {
      "source": "security@medtronic.com",
      "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins.html"
    }
  ],
  "sourceIdentifier": "security@medtronic.com",
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-502"
        }
      ],
      "source": "security@medtronic.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…