Details

Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric Iconics Digital Solutions GENESIS64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00, Mitsubishi Electric GENESIS64 all versions, Mitsubishi Electric MC Works64 all versions, and Mitsubishi Electric GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2025-7376"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-64"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-08-06T07:15:34Z",
    "severity": "MODERATE"
  },
  "details": "Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric Iconics Digital Solutions GENESIS64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00, Mitsubishi Electric GENESIS64 all versions, Mitsubishi Electric MC Works64 all versions, and Mitsubishi Electric GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.",
  "id": "GHSA-27f5-vx56-mg6g",
  "modified": "2025-08-06T09:30:35Z",
  "published": "2025-08-06T09:30:35Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-7376"
    },
    {
      "type": "WEB",
      "url": "https://jvn.jp/vu/JVNVU96364629"
    },
    {
      "type": "WEB",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-01"
    },
    {
      "type": "WEB",
      "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
      "type": "CVSS_V3"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…