ghsa-95h6-vgwg-qcqc
Vulnerability from github
Published
2025-05-07 18:30
Modified
2025-05-07 18:30
Details

A vulnerability in Cisco IOS Software for Cisco Catalyst 2960X, 2960XR, 2960CX, and 3560CX Series Switches could allow an authenticated, local attacker with privilege level 15 or an unauthenticated attacker with physical access to the device to execute persistent code at boot time and break the chain of trust.

This vulnerability is due to missing signature verification for specific files that may be loaded during the device boot process. An attacker could exploit this vulnerability by placing a crafted file into a specific location on an affected device. A successful exploit could allow the attacker to execute arbitrary code at boot time.

Because this allows the attacker to bypass a major security feature of the device, Cisco has raised the Security Impact Rating (SIR) of this advisory from Medium to High.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2025-20181"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-347"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-05-07T18:15:37Z",
    "severity": "MODERATE"
  },
  "details": "A vulnerability in Cisco IOS Software for Cisco Catalyst 2960X, 2960XR, 2960CX, and 3560CX Series Switches could allow an authenticated, local attacker with privilege level 15 or an unauthenticated attacker with physical access to the device to execute persistent code at boot time and break the chain of trust.\n\n This vulnerability is due to missing signature verification for specific files that may be loaded during the device boot process. An attacker could exploit this vulnerability by placing a crafted file into a specific location on an affected device. A successful exploit could allow the attacker to execute arbitrary code at boot time.\n\n Because this allows the attacker to bypass a major security feature of the device, Cisco has raised the Security Impact Rating (SIR) of this advisory from Medium to High.",
  "id": "GHSA-95h6-vgwg-qcqc",
  "modified": "2025-05-07T18:30:49Z",
  "published": "2025-05-07T18:30:49Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-20181"
    },
    {
      "type": "WEB",
      "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-c2960-3560-sboot-ZtqADrHq"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…