Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module and CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.
{ "affected": [], "aliases": [ "CVE-2025-3511" ], "database_specific": { "cwe_ids": [ "CWE-1284" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2025-04-25T06:15:45Z", "severity": "MODERATE" }, "details": "Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module and CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.", "id": "GHSA-f46p-qr4h-m6p4", "modified": "2025-04-25T06:30:56Z", "published": "2025-04-25T06:30:56Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-3511" }, { "type": "WEB", "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
CVE-2025-3511 (GCVE-0-2025-3511)
Vulnerability from cvelistv5
Published
2025-04-25 05:14
Modified
2025-04-25 19:13
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Summary
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module and CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.
References
► | URL | Tags |
---|---|---|
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-3511", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-25T19:07:34.363439Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-25T19:13:07.834Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-32D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-32T", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-32D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-32T", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GNCF1-32D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GNCF1-32T", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GNCE3-32D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN12A4-16D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN12A2-16T", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-16D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-16T", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-16D", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-16T", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "09 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "07 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "07 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "07 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "07 and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN FPGA module NZ2GN2S-D41P01", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN FPGA module NZ2GN2S-D41D01", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN FPGA module NZ2GN2S-D41PD02", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "01" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.08J and prior" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "1.08J and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module and CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets." } ], "value": "Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module and CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Denial-of-Service" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284 Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-25T05:14:43.758Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2025-3511", "datePublished": "2025-04-25T05:14:43.758Z", "dateReserved": "2025-04-11T04:10:12.030Z", "dateUpdated": "2025-04-25T19:13:07.834Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…