Vulnerability from github
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
{ "affected": [], "aliases": [ "CVE-2020-8476" ], "database_specific": { "cwe_ids": [ "CWE-20" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-04-29T02:15:00Z", "severity": "MODERATE" }, "details": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.", "id": "GHSA-jpj9-ccww-8gcw", "modified": "2022-10-28T12:00:34Z", "published": "2022-05-24T22:28:45Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-8476" }, { "type": "WEB", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "type": "WEB", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "type": "WEB", "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "type": "WEB", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "type": "CVSS_V3" } ] }
CVE-2020-8476 (GCVE-0-2020-8476)
Vulnerability from cvelistv5
- CWE-20 - Improper Input Validation
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | ABB | Central Licensing System |
Version: 5.1 < 5* |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:03:45.851Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Central Licensing System", "vendor": "ABB", "versions": [ { "lessThan": "5*", "status": "affected", "version": "5.1", "versionType": "custom" } ] }, { "product": "ABB Ability System 800xA", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" } ] }, { "product": "Compact HMI", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" } ] }, { "product": "Control Builder Safe", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1.0" }, { "status": "affected", "version": "1.1" }, { "status": "affected", "version": "2.0" } ] }, { "product": "Symphony Plus S+ Operations", "vendor": "ABB", "versions": [ { "lessThanOrEqual": "3.2", "status": "affected", "version": "3", "versionType": "custom" } ] }, { "product": "Symphony Plus S+ Engineering ", "vendor": "ABB", "versions": [ { "lessThanOrEqual": "2.2", "status": "affected", "version": "1.1", "versionType": "custom" } ] }, { "product": "Composer Harmony", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" } ] }, { "product": "Composer Melody ", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.3" }, { "lessThanOrEqual": "6.3", "status": "affected", "version": "6", "versionType": "custom" } ] }, { "product": "Harmony OPC Server Standalone", "vendor": "ABB", "versions": [ { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" }, { "status": "affected", "version": "7.0" } ] }, { "product": "Advant OCS Control Builder A", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1.3" }, { "status": "affected", "version": "1.4" } ] }, { "product": "Composer CTK", "vendor": "ABB", "versions": [ { "status": "affected", "version": "6.1" }, { "status": "affected", "version": "6.2" } ] }, { "product": "AdvaBuild", "vendor": "ABB", "versions": [ { "status": "affected", "version": "3.7 SP1" }, { "status": "affected", "version": "3.7 SP2" } ] }, { "product": "OPC Server for Mod 300 (non-800xA)", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1.4" } ] }, { "product": "OPC Data Link", "vendor": "ABB", "versions": [ { "status": "affected", "version": "2.1" }, { "status": "affected", "version": "2.2" } ] }, { "product": "Knowledge Manager", "vendor": "ABB", "versions": [ { "status": "affected", "version": "8.0" }, { "status": "affected", "version": "9.0" }, { "status": "affected", "version": "9.1" } ] }, { "product": "Manufacturing Operations Management", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1812" }, { "status": "affected", "version": "1909" } ] }, { "product": "Advant OCS AC 100 OPS Server", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" } ] }, { "product": "ABB Ability\u2122 SCADAvantage", "vendor": "ABB", "versions": [ { "lessThan": "unspecified", "status": "affected", "version": "5.1", "versionType": "custom" }, { "lessThanOrEqual": "5.6.5", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-28T00:00:00", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "ABB Central Licensing System - Elevation of Privilege Vulnerability", "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2020-8476", "datePublished": "2020-04-29T00:00:00", "dateReserved": "2020-01-30T00:00:00", "dateUpdated": "2024-08-04T10:03:45.851Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.