gsd-2017-14111
Vulnerability from gsd
Modified
2023-12-13 01:21
Details
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2017-14111", "description": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.", "id": "GSD-2017-14111" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2017-14111" ], "details": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.", "id": "GSD-2017-14111", "modified": "2023-12-13T01:21:12.400245Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-14111", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security", "refsource": "CONFIRM", "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security" }, { "name": "101850", "refsource": "BID", "url": "http://www.securityfocus.com/bid/101850" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:philips:intellispace_cardiovascular:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:philips:xcelera:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "r4.1l1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-14111" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-522" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security", "refsource": "CONFIRM", "tags": [ "Issue Tracking", "Mitigation", "Vendor Advisory" ], "url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01", "refsource": "MISC", "tags": [ "Issue Tracking", "US Government Resource", "Third Party Advisory" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-318-01" }, { "name": "101850", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/101850" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.2, "impactScore": 5.9 } }, "lastModifiedDate": "2019-10-03T00:03Z", "publishedDate": "2017-11-17T20:29Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…