gsd-2017-16745
Vulnerability from gsd
Modified
2023-12-13 01:21
Details
A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type ('type confusion') vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2017-16745",
    "description": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.",
    "id": "GSD-2017-16745"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2017-16745"
      ],
      "details": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.",
      "id": "GSD-2017-16745",
      "modified": "2023-12-13T01:21:00.556233Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2017-16745",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-843"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
            "refsource": "MISC",
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "refsource": "BID",
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:deltaww:delta_industrial_automation_screen_editor:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.00.23.00",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16745"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-704"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "tags": [
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 8.6,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": true
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "exploitabilityScore": 1.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2019-10-09T23:25Z",
      "publishedDate": "2018-03-15T23:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…