A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2017-7901", "description": "A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.", "id": "GSD-2017-7901" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2017-7901" ], "details": "A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.", "id": "GSD-2017-7901", "modified": "2023-12-13T01:21:07.150623Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2017-7901", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400", "version": { "version_data": [ { "version_value": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-343" } ] } ] }, "references": { "reference_data": [ { "name": "1038546", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1038546" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.000", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2017-7901" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-330" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04" }, { "name": "1038546", "refsource": "SECTRACK", "tags": [], "url": "http://www.securitytracker.com/id/1038546" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": true, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 8.5, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 4.7 } }, "lastModifiedDate": "2017-07-08T01:29Z", "publishedDate": "2017-06-30T03:29Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…