gsd-2018-3833
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn't check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server 'cache.insteon.com' and serve any signed firmware image.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2018-3833", "description": "An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn\u0027t check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server \u0027cache.insteon.com\u0027 and serve any signed firmware image.", "id": "GSD-2018-3833" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-3833" ], "details": "An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn\u0027t check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server \u0027cache.insteon.com\u0027 and serve any signed firmware image.", "id": "GSD-2018-3833", "modified": "2023-12-13T01:22:43.654101Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "DATE_PUBLIC": "2018-06-19T00:00:00", "ID": "CVE-2018-3833", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Insteon", "version": { "version_data": [ { "version_value": "Insteon Hub 2245-222 - Firmware version 1013" } ] } } ] }, "vendor_name": "Insteon" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn\u0027t check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server \u0027cache.insteon.com\u0027 and serve any signed firmware image." } ] }, "impact": { "cvss": { "baseScore": 8.6, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0512", "refsource": "MISC", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0512" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:insteon:hub_2245-222_firmware:1013:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:insteon:hub_2245-222:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2018-3833" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn\u0027t check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server \u0027cache.insteon.com\u0027 and serve any signed firmware image." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0512", "refsource": "MISC", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0512" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2023-02-03T18:40Z", "publishedDate": "2018-08-23T14:29Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…