gsd-2019-6581
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2019-6581",
    "description": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
    "id": "GSD-2019-6581"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2019-6581"
      ],
      "details": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
      "id": "GSD-2019-6581",
      "modified": "2023-12-13T01:23:49.106212Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2019-6581",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Siveillance VMS 2017 R2",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V11.2a"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Siveillance VMS 2018 R1",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V12.1a"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Siveillance VMS 2018 R2",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V12.2a"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Siveillance VMS 2018 R3",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V12.3a"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Siveillance VMS 2019 R1",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V13.1a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens AG"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-285: Improper Authorization"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf"
          },
          {
            "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01",
            "refsource": "MISC",
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r1:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "12.1a",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r2:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "12.2a",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r3:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "12.3a",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r1:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "13.1a",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:siveillance_video_management_software_2017_r2:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "11.2a",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6581"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2020-10-16T15:02Z",
      "publishedDate": "2019-06-12T14:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…