A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-6958", "description": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data.", "id": "GSD-2019-6958" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-6958" ], "details": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data.", "id": "GSD-2019-6958", "modified": "2023-12-13T01:23:49.911517Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2019-03-04T23:00:00.000Z", "ID": "CVE-2019-6958", "STATE": "PUBLIC", "TITLE": "Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data." } ] }, "generator": { "engine": "Vulnogram 0.0.6" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf", "refsource": "CONFIRM", "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf" } ] }, "solution": [ { "lang": "eng", "value": "The recommended approach is to update the software to a fixed version as soon as possible. Until a fixed software version is installed, the mitigation approaches firewalling, and IP filtering can be utilized. \n\nFor further informatation please check the published security advisory." } ], "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "9.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.7", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.4", "versionStartIncluding": "2.2", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.7.6.079", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.32.0099", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.10", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "0380.037", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "038.037", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-6958" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-306" } ] } ] }, "references": { "reference_data": [ { "name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf", "refsource": "CONFIRM", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2 } }, "lastModifiedDate": "2023-01-31T21:04Z", "publishedDate": "2019-05-29T19:29Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…