gsd-2019-9013
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-9013", "description": "An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.", "id": "GSD-2019-9013" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-9013" ], "details": "An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.", "id": "GSD-2019-9013", "modified": "2023-12-13T01:23:47.482004Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-9013", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-213-04", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-213-04" }, { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download=" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:raspberry_pi:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.16.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-9013" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-327" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-213-04", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-213-04" }, { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download=", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12943\u0026token=d097958a67ba382de688916f77e3013c0802fade\u0026download=" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-05-16T11:15Z", "publishedDate": "2019-08-15T17:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…