Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2021-35527",
    "description": "Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.",
    "id": "GSD-2021-35527"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-35527"
      ],
      "details": "Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions.",
      "id": "GSD-2021-35527",
      "modified": "2023-12-13T01:23:28.357141Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cybersecurity@hitachi-powergrids.com",
        "DATE_PUBLIC": "2021-07-14T12:00:00.000Z",
        "ID": "CVE-2021-35527",
        "STATE": "PUBLIC",
        "TITLE": "Password Autocomplete Vulnerability in Hitachi ABB Power Grids eSOMS Application"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "eSOMS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_value": "6.3"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Hitachi ABB Power Grids"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-200 Information Exposure"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A0957\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
            "refsource": "CONFIRM",
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A0957\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ]
      },
      "solution": [
        {
          "lang": "eng",
          "value": "The problem is remediated in eSOMS version 6.3.1."
        }
      ],
      "source": {
        "discovery": "USER"
      },
      "work_around": [
        {
          "lang": "eng",
          "value": "Recommended security best practices and firewall configurations can help protect a process control net-work from attacks that originate from outside the network. Such practices include ensuring critical applica-tions and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.  Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and docu-mented. Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing E-Mails or malicious web pages."
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:hitachienergy:esoms:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "6.3.1",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@hitachi-powergrids.com",
          "ID": "CVE-2021-35527"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-522"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A0957\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107992A0957\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2023-05-16T20:21Z",
      "publishedDate": "2021-07-14T14:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…