Client-side JavaScript controls may be bypassed to change user credentials and permissions without authentication, including a “root” user level meant only for the vendor. Web server root level access allows for changing of safety critical parameters.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-2105", "description": "Client-side JavaScript controls may be bypassed to change user credentials and permissions without authentication, including a \u201croot\u201d user level meant only for the vendor. Web server root level access allows for changing of safety critical parameters.", "id": "GSD-2022-2105" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-2105" ], "details": "Client-side JavaScript controls may be bypassed to change user credentials and permissions without authentication, including a \u201croot\u201d user level meant only for the vendor. Web server root level access allows for changing of safety critical parameters.", "id": "GSD-2022-2105", "modified": "2023-12-13T01:19:20.357117Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2022-06-23T17:01:00.000Z", "ID": "CVE-2022-2105", "STATE": "PUBLIC", "TITLE": "Secheron SEPCOS Control and Protection Relay" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SEPCOS Control and Protection Relay firmware package", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "All versions", "version_value": "1.23.21" }, { "version_affected": "\u003c", "version_name": "All versions", "version_value": "1.24.8" }, { "version_affected": "\u003c", "version_name": "All versions", "version_value": "1.25.3" } ] } } ] }, "vendor_name": "Secheron" } ] } }, "credit": [ { "lang": "eng", "value": "Anthony Candarini of AECOM, Clark Bradley of Elliott Davis, Mike Curnow of AECOM, and Balakrishna Subramoney of SAM Analytic Solutions reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Client-side JavaScript controls may be bypassed to change user credentials and permissions without authentication, including a \u201croot\u201d user level meant only for the vendor. Web server root level access allows for changing of safety critical parameters." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-841 IMPROPER ENFORCEMENT OF BEHAVIORAL WORKFLOW" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03" } ] }, "solution": [ { "lang": "eng", "value": "Secheron recommends updating its software to the latest version:\n\nSEPCOS Single Package firmware (1.23.xx feature level): Update to 1.23.22 or higher version\nSEPCOS Single Package firmware (1.24.xx feature level): Update to 1.24.8 or higher version\nSEPCOS Single Package firmware (1.25.xx feature level): Update to 1.25.3 or higher version" } ], "source": { "advisory": "ICSA-22-174-03", "discovery": "EXTERNAL" }, "work_around": [ { "lang": "eng", "value": "Additional workarounds are suggested to help reduce the risk:\n\nConfigure the network such that PLC communications are strictly limited to only the devices required to perform its functions.\nLimit remote access and close Ports 80 and 443 at the switch level.\nOnly use approved devices to connect to the PLCs. Do not connect personal peripherals (USB sticks, hotspots) to approved devices.\nCheck device logs during periodic maintenance for unauthorized changes or access." } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:secheron:sepcos_control_and_protection_relay_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.25.3", "versionStartIncluding": "1.25.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:secheron:sepcos_control_and_protection_relay_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.24.8", "versionStartIncluding": "1.24.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:secheron:sepcos_control_and_protection_relay_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.23.21", "versionStartIncluding": "1.23.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:secheron:sepcos_control_and_protection_relay:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2105" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Client-side JavaScript controls may be bypassed to change user credentials and permissions without authentication, including a \u201croot\u201d user level meant only for the vendor. Web server root level access allows for changing of safety critical parameters." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-174-03" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2 } }, "lastModifiedDate": "2022-07-06T12:34Z", "publishedDate": "2022-06-24T15:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…