gsd-2023-35124
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
An information disclosure vulnerability exists in the OAS Engine configuration management functionality of Open Automation Software OAS Platform v18.00.0072. A specially crafted series of network requests can lead to a disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-35124", "id": "GSD-2023-35124" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-35124" ], "details": "An information disclosure vulnerability exists in the OAS Engine configuration management functionality of Open Automation Software OAS Platform v18.00.0072. A specially crafted series of network requests can lead to a disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability.", "id": "GSD-2023-35124", "modified": "2023-12-13T01:20:45.935117Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2023-35124", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "OAS Platform", "version": { "version_data": [ { "version_affected": "=", "version_value": "v18.00.0072" } ] } } ] }, "vendor_name": "Open Automation Software" } ] } }, "credits": [ { "lang": "en", "value": "Discovered by a member of Cisco Talos." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An information disclosure vulnerability exists in the OAS Engine configuration management functionality of Open Automation Software OAS Platform v18.00.0072. A specially crafted series of network requests can lead to a disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability." } ] }, "impact": { "cvss": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-209", "lang": "eng", "value": "CWE-209: Information Exposure Through an Error Message" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1775", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1775" }, { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1775", "refsource": "MISC", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1775" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:openautomationsoftware:oas_platform:18.00.0072:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2023-35124" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the OAS Engine configuration management functionality of Open Automation Software OAS Platform v18.00.0072. A specially crafted series of network requests can lead to a disclosure of sensitive information. An attacker can send a sequence of requests to trigger this vulnerability." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-209" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1775", "refsource": "MISC", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1775" }, { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1775", "refsource": "MISC", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1775" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4 } }, "lastModifiedDate": "2023-09-08T17:28Z", "publishedDate": "2023-09-05T17:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.