ssa-042050
Vulnerability from csaf_siemens
Published
2023-06-13 00:00
Modified
2024-12-10 00:00
Summary
SSA-042050: Know-How Protection Mechanism Failure in TIA Portal
Notes
Summary
The know-how protection feature in Totally Integrated Automation Portal (TIA Portal) does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.
Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "The know-how protection feature in Totally Integrated Automation Portal (TIA Portal) does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.\n\nSiemens recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-042050: Know-How Protection Mechanism Failure in TIA Portal - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-042050.html" }, { "category": "self", "summary": "SSA-042050: Know-How Protection Mechanism Failure in TIA Portal - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-042050.json" } ], "title": "SSA-042050: Know-How Protection Mechanism Failure in TIA Portal", "tracking": { "current_release_date": "2024-12-10T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-042050", "initial_release_date": "2023-06-13T00:00:00Z", "revision_history": [ { "date": "2023-06-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-12-12T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added Totally Integrated Automation Portal (TIA Portal) V19 as affected product" }, { "date": "2024-12-10T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "No fix planned for Totally Integrated Automation Portal (TIA Portal) V19; Added Totally Integrated Automation Portal (TIA Portal) V20 as affected product" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V14", "product_id": "1" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V14" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15", "product_id": "2" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V15.1", "product_id": "3" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V15.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "4" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "5" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "6" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V19", "product_id": "7" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V19" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V20", "product_id": "8" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V20" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-30757", "cwe": { "id": "CWE-693", "name": "Protection Mechanism Failure" }, "notes": [ { "category": "summary", "text": "The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated.\r\n\r\nThis could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8" ] }, "remediations": [ { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://docs.tia.siemens.cloud/r/en-us/v20/protecting-blocks)", "product_ids": [ "8" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109742284?c=87347935883)", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109755202?c=105012867723)", "product_ids": [ "3" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109764516?c=105012867723)", "product_ids": [ "2" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109773506?c=126979557387)", "product_ids": [ "4" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109798671?c=132780438283)", "product_ids": [ "5" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109815056?c=132780438283)", "product_ids": [ "6" ] }, { "category": "mitigation", "details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapters \"Security information\" and \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/ww/en/view/109826862/)", "product_ids": [ "7" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8" ] } ], "title": "CVE-2023-30757" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…