Vulnerabilites related to Schneider Electric - ION8800
CVE-2023-5985 (GCVE-0-2023-5985)
Vulnerability from cvelistv5
Published
2023-11-15 03:35
Modified
2024-08-29 15:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability
exists that could cause compromise of a user’s browser when an attacker with admin privileges
has modified system values.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Schneider Electric | ION8650 |
Version: All versions |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:25.120Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-5985", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-29T15:18:22.109304Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-29T15:18:46.931Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ION8650", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unaffected", "product": "ION8800 ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2023-11-15T03:25:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\nexists that could cause compromise of a user\u2019s browser when an attacker with admin privileges\nhas modified system values.\n\n\n\n" } ], "value": "\n\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\nexists that could cause compromise of a user\u2019s browser when an attacker with admin privileges\nhas modified system values.\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-15T03:35:17.617Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-5985", "datePublished": "2023-11-15T03:35:17.617Z", "dateReserved": "2023-11-07T10:56:13.627Z", "dateUpdated": "2024-08-29T15:18:46.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-5984 (GCVE-0-2023-5984)
Vulnerability from cvelistv5
Published
2023-11-15 03:30
Modified
2024-08-02 08:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-494 - Download of Code Without Integrity Check
Summary
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow
modified firmware to be uploaded when an authorized admin user begins a firmware update
procedure which could result in full control over the device.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Schneider Electric | ION8650 |
Version: All versions |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:25.140Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ION8650", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unaffected", "product": "ION8800 ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2023-11-15T03:25:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow\nmodified firmware to be uploaded when an authorized admin user begins a firmware update\nprocedure which could result in full control over the device.\n\n" } ], "value": "\nA CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow\nmodified firmware to be uploaded when an authorized admin user begins a firmware update\nprocedure which could result in full control over the device.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-494", "description": "CWE-494 Download of Code Without Integrity Check", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-14T05:04:52.005Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-5984", "datePublished": "2023-11-15T03:30:09.897Z", "dateReserved": "2023-11-07T10:54:44.542Z", "dateUpdated": "2024-08-02T08:14:25.140Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }