Summary
Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.
Impacted products
Vendor Product Version
ni labview *
ni labwindows *
ni measurementstudio *
ni teststand *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3815CFE4-4E5E-44BB-B206-520C39DE3674",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC46A398-C8F3-49B2-BDDE-20DEA80EC941",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461",
              "versionEndIncluding": "2013",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "68051582-D70F-4B32-A9F9-64A5E33CB481",
              "versionEndIncluding": "2012",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de salto de ruta (path) en el control de 3D Graph ActiveX en el archivo cw3dgrph.ocx en LabWindows/CVI 2012 SP1 y anteriores, LabVIEW 2012 SP1 y anteriores, y otros productos de National Instruments, permiten a los atacantes remotos crear y ejecutar archivos arbitrarios por medio de una ruta (path) de acceso completa en un argumento para el m\u00e9todo ExportStyle, en conjunci\u00f3n con el contenido del archivo en el valor de la propiedad (a) Caption  o (b) FormatString."
    }
  ],
  "id": "CVE-2013-5022",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-08-06T20:55:05.413",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2013-08-06 20:55
Modified
2025-04-11 00:51
Severity ?
Summary
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Impacted products
Vendor Product Version
ni labview *
ni labwindows *
ni measurementstudio *
ni teststand *
abb datamanager 1.0.0
abb datamanager 6.3.6



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3815CFE4-4E5E-44BB-B206-520C39DE3674",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC46A398-C8F3-49B2-BDDE-20DEA80EC941",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461",
              "versionEndIncluding": "2013",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "68051582-D70F-4B32-A9F9-64A5E33CB481",
              "versionEndIncluding": "2012",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:abb:datamanager:1.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A711CA4A-494A-4702-A620-7B09F1FA8495",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:abb:datamanager:6.3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "899330B9-95DB-4229-9BE9-41384016AC12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples vulnerabilidades de salto de ruta (path) en el archivo cwui.ocx de National Instruments , como se usado en National Instruments LabWindows/CVI 2012 SP1 y anteriores, National Instruments LabVIEW 2012 SP1 y anteriores, el componente de Data Analysis en ABB DataManager versi\u00f3n 1 hasta 6.3.6, y otros productos permiten atacantes remotos crear y ejecutar archivos arbitrarios por medio de un acceso de ruta (path) completo en un argumento del m\u00e9todo ExportStyle en el control de (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide o (5) ActiveX CWKnob, en conjunci\u00f3n con el contenido del archivo en el valor de la propiedad (a) Caption  o (b) FormatString."
    }
  ],
  "id": "CVE-2013-5021",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2013-08-06T20:55:05.287",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-09 20:15
Modified
2025-08-18 19:36
Summary
Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW in InitCPUInformation() that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW in InitCPUInformation() that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de escritura fuera de los l\u00edmites debido a una comprobaci\u00f3n incorrecta de los l\u00edmites en NI LabVIEW en InitCPUInformation(), que puede provocar la divulgaci\u00f3n de informaci\u00f3n o la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, el atacante debe obligar al usuario a abrir un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-2631",
  "lastModified": "2025-08-18T19:36:03.480",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-09T20:15:27.183",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-vulnerabilities-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-23 14:15
Modified
2024-11-21 09:42
Summary
A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*",
              "matchCriteriaId": "9F184512-5D11-47F4-8555-EA6FF93C106F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": " Un problema de corrupci\u00f3n de memoria debido a una verificaci\u00f3n de longitud inadecuada en NI LabVIEW puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-4081",
  "lastModified": "2024-11-21T09:42:09.460",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-23T14:15:14.837",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-12-10 16:15
Modified
2025-03-04 18:37
Summary
An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una lectura fuera de los l\u00edmites debido a una validaci\u00f3n de entrada incorrecta al cargar la tabla de fuentes en fontmgr.cpp en NI LabVIEW puede revelar informaci\u00f3n o provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, es necesario que un atacante proporcione a un usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q3 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-10495",
  "lastModified": "2025-03-04T18:37:45.737",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "LOW",
          "subIntegrityImpact": "LOW",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-12-10T16:15:22.080",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview-.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-07-23 16:15
Modified
2025-08-19 16:14
Summary
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "1FB7783C-FCB2-4564-98CF-F76F848E8E86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch6:*:*:*:*:*:*",
              "matchCriteriaId": "F25A1816-08CA-4467-8025-AD57562D7C35",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "3B759A99-F766-4FE4-A1FF-A2D5026A6BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "55237E7D-9149-4204-A8FE-354CD2BC1220",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de lectura fuera de los l\u00edmites, debida a una comprobaci\u00f3n incorrecta de los l\u00edmites en NI LabVIEW en fontmgr, puede provocar la divulgaci\u00f3n de informaci\u00f3n o la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, el atacante debe obligar al usuario a abrir un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-2634",
  "lastModified": "2025-08-19T16:14:55.217",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-23T16:15:25.620",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-09-05 18:29
Modified
2025-04-20 01:37
Summary
An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution.
Impacted products
Vendor Product Version
ni labview 2014
ni labview 2015
ni labview 2016
ni labview 2017



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:2014:*:*:*:*:*:*:*",
              "matchCriteriaId": "34D03DA4-6434-4EE4-8F0A-DF22DFEBF126",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2015:*:*:*:*:*:*:*",
              "matchCriteriaId": "F116DEDC-3AEF-4382-8C05-1748CC4BEFB7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2016:*:*:*:*:*:*:*",
              "matchCriteriaId": "D95C08DE-6E3F-4BE9-AF26-7179CA2C96B7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2017:*:*:*:*:*:*:*",
              "matchCriteriaId": "5509E419-FDAF-43CE-BB61-DF77A3CDF59A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de corrupci\u00f3n de memoria explotable en la funcionalidad de an\u00e1lisis de segmentos RSRC de LabVIEW 2017, LabVIEW 2016, LabVIEW 2015 y LabVIEW 2014. Un archivo de Instrumento Virtual (VI) especialmente dise\u00f1ado puede causar una condici\u00f3n de bucle controlada por un atacante que resulta en una escritura nula arbitraria. Un archivo VI controlado por un atacante puede ser utilizado para desencadenar esta vulnerabilidad y puede potencialmente resultar en la ejecuci\u00f3n de c\u00f3digo"
    }
  ],
  "id": "CVE-2017-2779",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-09-05T18:29:00.257",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "http://www.ni.com/product-documentation/54099/en/"
    },
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100519"
    },
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://0patch.blogspot.com/2017/09/0patching-rsrc-arbitrary-null-write.html"
    },
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0273"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "http://www.ni.com/product-documentation/54099/en/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100519"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://0patch.blogspot.com/2017/09/0patching-rsrc-arbitrary-null-write.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0273"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-23 14:15
Modified
2024-11-21 09:42
Summary
An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*",
              "matchCriteriaId": "9F184512-5D11-47F4-8555-EA6FF93C106F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una lectura fuera de los l\u00edmites debido a una verificaci\u00f3n de l\u00edmites faltantes en LabVIEW puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-4079",
  "lastModified": "2024-11-21T09:42:09.197",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-23T14:15:14.353",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-04-21 05:15
Modified
2024-11-21 06:55
Summary
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:flexlogger:2021:r2:*:*:*:*:*:*",
              "matchCriteriaId": "CE96AE31-D36F-446A-96A5-46C762818A96",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:flexlogger:2021:r3:*:*:*:*:*:*",
              "matchCriteriaId": "336F1E07-92EE-4BF5-AA14-981BFB67965C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:flexlogger:2021:r4:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A4BF7-5BF0-4EE5-BF7C-8C514D6238B5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:g_web_development_software:2021:*:*:*:-:*:*:*",
              "matchCriteriaId": "135688EB-A45C-4837-8ADC-CE0E0393457D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:g_web_development_software:2021:*:*:*:community:*:*:*",
              "matchCriteriaId": "EF01F242-0C8B-457E-8116-6B144AEB94C2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*",
              "matchCriteriaId": "F46539B2-9084-45E3-B9D6-447C9E002C0C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:community:*:*:*",
              "matchCriteriaId": "BF15292D-3504-4386-BD9B-99A65FE22A2D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:static_test_software_suite:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "738E76CB-643A-424E-85B0-65B6CFEB24B0",
              "versionEndExcluding": "1.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:systemlink:2020:r4:*:*:*:*:*:*",
              "matchCriteriaId": "3C507CEF-2AB1-4CF7-A66F-D3EAABA1D626",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:systemlink:2022:r1:*:*:*:*:*:*",
              "matchCriteriaId": "10ED5155-30C4-4278-82EF-DDEC2C12E9D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:systemlink:2022:r2:*:*:*:*:*:*",
              "matchCriteriaId": "670B26C0-2ECE-4AC9-A3C2-3340D8F02040",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) en un componente de NI Web Server instalado con varios productos de NI. Dependiendo del producto(s) en uso, la gu\u00eda de remediaci\u00f3n incluye: instalar SystemLink versi\u00f3n 2021 R3 o posterior, instalar FlexLogger 2022 Q2 o posterior, instalar LabVIEW 2021 SP1, instalar G Web Development 2022 R1 o posterior, o instalar Static Test Software Suite versi\u00f3n 1.2 o posterior"
    }
  ],
  "id": "CVE-2022-27237",
  "lastModified": "2024-11-21T06:55:28.160",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-04-21T05:15:06.800",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en-us/support/documentation/supplemental/22/cross-site-scripting-vulnerability--in-ni-web-server-component.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en-us/support/documentation/supplemental/22/cross-site-scripting-vulnerability--in-ni-web-server-component.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-12-10 16:15
Modified
2025-03-04 18:35
Summary
An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una lectura fuera de los l\u00edmites debido a una validaci\u00f3n de entrada incorrecta en BuildFontMap en fontmgr.cpp en NI LabVIEW puede revelar informaci\u00f3n o provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, es necesario que un atacante proporcione a un usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q3 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-10496",
  "lastModified": "2025-03-04T18:35:39.467",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "LOW",
          "subIntegrityImpact": "LOW",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-12-10T16:15:22.203",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview-.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-09 19:15
Modified
2025-08-18 19:40
Summary
There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW. This vulnerability may result in arbitrary code execution. Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de secuestro de DLL debido a una ruta de b\u00fasqueda no controlada en NI LabVIEW. Esta vulnerabilidad puede provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla correctamente, un atacante debe insertar una DLL maliciosa en la ruta de b\u00fasqueda no controlada. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-2630",
  "lastModified": "2025-08-18T19:40:32.253",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.3,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.0,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-09T19:15:48.490",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/dll-hijacking-vulnerability-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-03-11 16:15
Modified
2025-02-27 17:51
Summary
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*",
              "matchCriteriaId": "F46539B2-9084-45E3-B9D6-447C9E002C0C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Una escritura fuera de los l\u00edmites debido a una verificaci\u00f3n de los l\u00edmites faltantes en LabVIEW puede resultar en la ejecuci\u00f3n remota de c\u00f3digo. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-23610",
  "lastModified": "2025-02-27T17:51:42.177",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-03-11T16:15:08.370",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-03-31 18:59
Modified
2025-04-20 01:37
Summary
An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabVIEW before 2015 SP1 f7 Patch and 2016 before f2 Patch. A specially crafted VI file can cause a user controlled value to be used as a loop terminator resulting in internal heap corruption. An attacker controlled VI file can be used to trigger this vulnerability, exploitation could lead to remote code execution.
Impacted products
Vendor Product Version
ni labview 16.0.0.49152



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:16.0.0.49152:*:*:*:*:*:*:*",
              "matchCriteriaId": "710241F0-A0E9-4296-8CED-EB4FBB674060",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabVIEW before 2015 SP1 f7 Patch and 2016 before f2 Patch. A specially crafted VI file can cause a user controlled value to be used as a loop terminator resulting in internal heap corruption. An attacker controlled VI file can be used to trigger this vulnerability, exploitation could lead to remote code execution."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de corrupci\u00f3n de memoria explotable en la funcionalidad LvVariantUnflatten en versiones de LabVIEW de 64 bits anterior a versi\u00f3n 2015 SP1 Parche f7 y versiones 2016 anteriores a Parche f2. Un archivo VI especialmente dise\u00f1ado puede causar que un valor controlado por el usuario sea usado como un terminador de bucle resultando en una corrupci\u00f3n de pila interna. Se puede usar un archivo VI controlado por un atacante para activar esta vulnerabilidad, la explotaci\u00f3n podr\u00eda conllevar a la ejecuci\u00f3n de c\u00f3digo remota."
    }
  ],
  "id": "CVE-2017-2775",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-03-31T18:59:00.483",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "url": "http://www.ni.com/product-documentation/53778/en/"
    },
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/97020"
    },
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Technical Description",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.talosintelligence.com/reports/TALOS-2017-0269/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.ni.com/product-documentation/53778/en/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/97020"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Technical Description",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.talosintelligence.com/reports/TALOS-2017-0269/"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-07-29 22:15
Modified
2025-08-19 15:43
Summary
A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "1FB7783C-FCB2-4564-98CF-F76F848E8E86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch6:*:*:*:*:*:*",
              "matchCriteriaId": "F25A1816-08CA-4467-8025-AD57562D7C35",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "3B759A99-F766-4FE4-A1FF-A2D5026A6BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "55237E7D-9149-4204-A8FE-354CD2BC1220",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de corrupci\u00f3n de memoria en NI LabVIEW debido a la gesti\u00f3n incorrecta de errores cuando un VILinkObj es nulo. Esta vulnerabilidad puede provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, un atacante debe obligar al usuario a abrir un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-7849",
  "lastModified": "2025-08-19T15:43:11.880",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-29T22:15:26.030",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-03-11 16:15
Modified
2025-02-27 18:11
Summary
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*",
              "matchCriteriaId": "F46539B2-9084-45E3-B9D6-447C9E002C0C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An improper error handling vulnerability in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de manejo incorrecto de errores en LabVIEW puede resultar en la ejecuci\u00f3n remota de c\u00f3digo. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-23612",
  "lastModified": "2025-02-27T18:11:29.183",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-03-11T16:15:08.743",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-22 20:15
Modified
2025-03-06 19:32
Summary
An integer overflow vulnerability due to improper input validation when reading TDMS files in LabVIEW may result in an infinite loop. Successful exploitation requires an attacker to provide a user with a specially crafted TDMS file. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An integer overflow vulnerability due to improper input validation when reading TDMS files in LabVIEW may result in an infinite loop.  Successful exploitation requires an attacker to provide a user with a specially crafted TDMS file.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de desbordamiento de enteros debido a una validaci\u00f3n de entrada incorrecta al leer archivos TDMS en LabVIEW puede resultar en un bucle infinito. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un archivo TDMS especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-6638",
  "lastModified": "2025-03-06T19:32:31.013",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-22T20:15:04.723",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/integer-overflow-vulnerability-reading-tdms-files-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/integer-overflow-vulnerability-reading-tdms-files-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-190"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-190"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-07-29 22:15
Modified
2025-08-19 16:31
Summary
A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "1FB7783C-FCB2-4564-98CF-F76F848E8E86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch6:*:*:*:*:*:*",
              "matchCriteriaId": "F25A1816-08CA-4467-8025-AD57562D7C35",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "3B759A99-F766-4FE4-A1FF-A2D5026A6BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "55237E7D-9149-4204-A8FE-354CD2BC1220",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de corrupci\u00f3n de memoria en NI LabVIEW debido a una validaci\u00f3n de entrada incorrecta en lvpict.cpp que puede provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, un atacante debe obligar al usuario a abrir un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-7848",
  "lastModified": "2025-08-19T16:31:04.400",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-29T22:15:25.870",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-23 14:15
Modified
2024-11-21 09:42
Summary
A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*",
              "matchCriteriaId": "9F184512-5D11-47F4-8555-EA6FF93C106F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": " Un problema de corrupci\u00f3n de memoria debido a una verificaci\u00f3n de longitud incorrecta en LabVIEW tdcore.dll puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-4080",
  "lastModified": "2024-11-21T09:42:09.330",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-23T14:15:14.590",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-12-10 16:15
Modified
2025-03-04 18:40
Summary
An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una lectura fuera de los l\u00edmites debido a una validaci\u00f3n de entrada incorrecta en HeapObjMapImpl.cpp en NI LabVIEW puede revelar informaci\u00f3n o provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, es necesario que un atacante proporcione a un usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q3 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-10494",
  "lastModified": "2025-03-04T18:40:13.210",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "LOW",
          "subIntegrityImpact": "LOW",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-12-10T16:15:21.930",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview-.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2013-08-06 20:55
Modified
2025-04-11 00:51
Severity ?
Summary
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files.
Impacted products
Vendor Product Version
ni diadem *
ni labview *
ni labwindows *
ni measurementstudio *
ni teststand *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:diadem:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "651A3465-0A7A-4EE2-B46E-D1E6972767A6",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3815CFE4-4E5E-44BB-B206-520C39DE3674",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC46A398-C8F3-49B2-BDDE-20DEA80EC941",
              "versionEndIncluding": "2012",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461",
              "versionEndIncluding": "2013",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "68051582-D70F-4B32-A9F9-64A5E33CB481",
              "versionEndIncluding": "2012",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad sin especificar en un control ActiveX en el componente HelpAsst en NI Help Links in National Instruments LabWindows/CVI, LabVIEW, y otros productos, tiene un impacto desconocido y vectores de ataque remotos."
    }
  ],
  "id": "CVE-2013-5023",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2013-08-06T20:55:05.453",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-03-11 16:15
Modified
2025-02-27 17:51
Summary
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*",
              "matchCriteriaId": "F46539B2-9084-45E3-B9D6-447C9E002C0C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.\n\n"
    },
    {
      "lang": "es",
      "value": "Una escritura fuera de los l\u00edmites debido a una verificaci\u00f3n de los l\u00edmites faltantes en LabVIEW puede resultar en la ejecuci\u00f3n remota de c\u00f3digo. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-23611",
  "lastModified": "2025-02-27T17:51:47.873",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-03-11T16:15:08.557",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-09 20:15
Modified
2025-08-18 19:33
Summary
Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW reading CPU info from cache that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW reading CPU info from cache that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de escritura fuera de los l\u00edmites debido a una comprobaci\u00f3n incorrecta de los l\u00edmites en NI LabVIEW al leer informaci\u00f3n de la CPU desde la cach\u00e9, lo que puede provocar la divulgaci\u00f3n de informaci\u00f3n o la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, el atacante debe obligar al usuario a abrir un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-2632",
  "lastModified": "2025-08-18T19:33:43.857",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-09T20:15:27.350",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-vulnerabilities-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-03-11 16:15
Modified
2025-02-27 17:51
Summary
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*",
              "matchCriteriaId": "F46539B2-9084-45E3-B9D6-447C9E002C0C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\n"
    },
    {
      "lang": "es",
      "value": "Una escritura fuera de los l\u00edmites debido a una verificaci\u00f3n de los l\u00edmites faltantes en LabVIEW puede resultar en la ejecuci\u00f3n remota de c\u00f3digo. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-23608",
  "lastModified": "2025-02-27T17:51:32.090",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-03-11T16:15:07.897",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-07-23 16:15
Modified
2025-08-19 16:11
Summary
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "1FB7783C-FCB2-4564-98CF-F76F848E8E86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch6:*:*:*:*:*:*",
              "matchCriteriaId": "F25A1816-08CA-4467-8025-AD57562D7C35",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "3B759A99-F766-4FE4-A1FF-A2D5026A6BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "55237E7D-9149-4204-A8FE-354CD2BC1220",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de lectura fuera de los l\u00edmites debido a una comprobaci\u00f3n incorrecta de los l\u00edmites en NI LabVIEW en lvre!UDecStrToNum, que puede provocar la divulgaci\u00f3n de informaci\u00f3n o la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, el atacante debe obligar al usuario a abrir un VI especialmente manipulado. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-2633",
  "lastModified": "2025-08-19T16:11:46.920",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-23T16:15:25.013",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-07-29 22:15
Modified
2025-08-19 16:20
Summary
A code injection vulnerability due to an improper initialization check exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI using a CIN node. This vulnerability affects 32-bit NI LabVIEW 2025 Q1 and prior versions. LabVIEW 64-bit versions do not support CIN nodes and are not affected.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025
ni labview 2025
microsoft windows -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "1FB7783C-FCB2-4564-98CF-F76F848E8E86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch6:*:*:*:*:*:*",
              "matchCriteriaId": "F25A1816-08CA-4467-8025-AD57562D7C35",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "3B759A99-F766-4FE4-A1FF-A2D5026A6BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "55237E7D-9149-4204-A8FE-354CD2BC1220",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:x86:*",
              "matchCriteriaId": "60366048-32FE-4081-A852-04319FD7A52C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A code injection vulnerability due to an improper initialization check exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI using a CIN node.  This vulnerability affects 32-bit NI LabVIEW 2025 Q1 and prior versions.  LabVIEW 64-bit versions do not support CIN nodes and are not affected."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de inyecci\u00f3n de c\u00f3digo en NI LabVIEW debido a una comprobaci\u00f3n de inicializaci\u00f3n incorrecta que puede provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla con \u00e9xito, un atacante debe obligar al usuario a abrir un VI especialmente manipulado mediante un nodo CIN. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 de 32 bits y versiones anteriores. Las versiones de LabVIEW de 64 bits no son compatibles con nodos CIN y no se ven afectadas."
    }
  ],
  "id": "CVE-2025-7361",
  "lastModified": "2025-08-19T16:20:55.313",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.5,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-29T22:15:25.710",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/code-injection-vulnerability-in-ni-labview-using-cin-nodes.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-09 19:15
Modified
2025-08-18 19:47
Summary
There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW when loading NI Error Reporting. This vulnerability may result in arbitrary code execution. Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2024
ni labview 2025
ni labview 2025



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807AE6D5-8096-47A2-A47D-1A5EFC85652D",
              "versionEndIncluding": "2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "52CC3023-4913-40BA-B74C-786F32DC7551",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "FC150E98-5889-4A65-84B8-E4871091D104",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "85B3D429-4F3D-44CC-9304-837FB6D7E2A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch3:*:*:*:*:*:*",
              "matchCriteriaId": "26EEE5E3-AD37-4832-A66C-5F8F7A478F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch4:*:*:*:*:*:*",
              "matchCriteriaId": "5DC20B17-C582-42C4-9780-5DC61B4AED91",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch5:*:*:*:*:*:*",
              "matchCriteriaId": "329575A0-F12E-478B-9A83-F747D6A161AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "953E8FD0-4420-4592-B696-C377D4EE0CA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3:*:*:*:*:*:*",
              "matchCriteriaId": "5D99DCCD-511E-482E-8307-24382D1B621B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "600A4905-B888-454F-9DF6-1C09FB71DBE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "AD79D082-AFF5-42CB-9D6C-12CF9A59D205",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1:*:*:*:*:*:*",
              "matchCriteriaId": "FB0991CF-642F-46D2-9C47-9540347DC074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2025:q1_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "D776E6DE-2635-4172-B08D-B7FB2D1048F9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW when loading NI Error Reporting.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de secuestro de DLL debido a una ruta de b\u00fasqueda no controlada en NI LabVIEW al cargar NI Error Reporting. Esta vulnerabilidad puede provocar la ejecuci\u00f3n de c\u00f3digo arbitrario. Para explotarla correctamente, un atacante debe insertar una DLL maliciosa en la ruta de b\u00fasqueda no controlada. Esta vulnerabilidad afecta a NI LabVIEW 2025 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2025-2629",
  "lastModified": "2025-08-18T19:47:18.057",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.3,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "LOCAL",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.0,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "security@ni.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-09T19:15:48.320",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/dll-hijacking-vulnerability-in-ni-labview-when-loading-ni-error-reporting.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-03-11 16:15
Modified
2025-02-27 18:11
Summary
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
ni labview *
ni labview 2021
ni labview 2021
ni labview 2022
ni labview 2022
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2023
ni labview 2024



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04",
              "versionEndIncluding": "2020",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*",
              "matchCriteriaId": "F46539B2-9084-45E3-B9D6-447C9E002C0C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
              "matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
              "matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
              "matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
              "matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*",
              "matchCriteriaId": "91928C9C-F094-4EE4-9FBE-2B7956D68E6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
              "matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
              "matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An improper error handling vulnerability in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de manejo incorrecto de errores en LabVIEW puede resultar en la ejecuci\u00f3n remota de c\u00f3digo. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
    }
  ],
  "id": "CVE-2024-23609",
  "lastModified": "2025-02-27T18:11:32.143",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "security@ni.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-03-11T16:15:08.157",
  "references": [
    {
      "source": "security@ni.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
    }
  ],
  "sourceIdentifier": "security@ni.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1285"
        }
      ],
      "source": "security@ni.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2025-7848 (GCVE-0-2025-7848)
Vulnerability from cvelistv5
Published
2025-07-29 21:24
Modified
2025-08-02 03:55
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.5
Version: 23.0.0    23.3.6
Version: 24.0.0    24.3.3
Version: 25.0.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7848",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-01T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-02T03:55:47.625Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Rocco Calvi (@TecR0c) with TecSecurity working with Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-29T21:24:32.568Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Missing input check in lvpict.cpp used in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-7848",
    "datePublished": "2025-07-29T21:24:32.568Z",
    "dateReserved": "2025-07-18T21:43:07.604Z",
    "dateUpdated": "2025-08-02T03:55:47.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-5021 (GCVE-0-2013-5021)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
CWE
  • n/a
Summary
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:59:41.367Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-05-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-09-17T09:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-5021",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/$file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf",
              "refsource": "CONFIRM",
              "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/$file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf"
            },
            {
              "name": "http://zerodayinitiative.com/advisories/ZDI-13-120/",
              "refsource": "MISC",
              "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/"
            },
            {
              "name": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument"
            },
            {
              "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-5021",
    "datePublished": "2013-08-06T18:00:00",
    "dateReserved": "2013-07-31T00:00:00",
    "dateUpdated": "2024-08-06T16:59:41.367Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7361 (GCVE-0-2025-7361)
Vulnerability from cvelistv5
Published
2025-07-29 21:19
Modified
2025-08-02 03:55
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
A code injection vulnerability due to an improper initialization check exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI using a CIN node. This vulnerability affects 32-bit NI LabVIEW 2025 Q1 and prior versions. LabVIEW 64-bit versions do not support CIN nodes and are not affected.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.5
Version: 23.0.0    23.3.6
Version: 24.0.0    24.3.3
Version: 25.0.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7361",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-01T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-02T03:55:46.530Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "32 bit"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA code injection vulnerability due to an improper initialization check exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI using a CIN node.  This vulnerability affects 32-bit NI LabVIEW 2025 Q1 and prior versions.  LabVIEW 64-bit versions do not support CIN nodes and are not affected.\u003c/p\u003e"
            }
          ],
          "value": "A code injection vulnerability due to an improper initialization check exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI using a CIN node.  This vulnerability affects 32-bit NI LabVIEW 2025 Q1 and prior versions.  LabVIEW 64-bit versions do not support CIN nodes and are not affected."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-29T21:19:28.118Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/code-injection-vulnerability-in-ni-labview-using-cin-nodes.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Code Injection Vulnerability in NI LabVIEW when using CIN nodes",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-7361",
    "datePublished": "2025-07-29T21:19:28.118Z",
    "dateReserved": "2025-07-08T16:56:14.380Z",
    "dateUpdated": "2025-08-02T03:55:46.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27237 (GCVE-0-2022-27237)
Vulnerability from cvelistv5
Published
2022-04-21 04:32
Modified
2024-08-03 05:25
Severity ?
CWE
  • n/a
Summary
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:25:32.493Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.ni.com/en-us/support/documentation/supplemental/22/cross-site-scripting-vulnerability--in-ni-web-server-component.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-21T04:32:44",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.ni.com/en-us/support/documentation/supplemental/22/cross-site-scripting-vulnerability--in-ni-web-server-component.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-27237",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ni.com/en-us/support/documentation/supplemental/22/cross-site-scripting-vulnerability--in-ni-web-server-component.html",
              "refsource": "CONFIRM",
              "url": "https://www.ni.com/en-us/support/documentation/supplemental/22/cross-site-scripting-vulnerability--in-ni-web-server-component.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-27237",
    "datePublished": "2022-04-21T04:32:44",
    "dateReserved": "2022-03-18T00:00:00",
    "dateUpdated": "2024-08-03T05:25:32.493Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2634 (GCVE-0-2025-2634)
Vulnerability from cvelistv5
Published
2025-07-23 15:53
Modified
2025-07-23 20:10
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0
Version: 23.0.0    23.3.6
Version: 24.0.0    24.3.3
Version: 25.0.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2634",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:09:47.785454Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:10:00.301Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "sem"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eOut of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-23T15:53:25.130Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Read Vulnerability in NI LabVIEW when building font map",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-2634",
    "datePublished": "2025-07-23T15:53:25.130Z",
    "dateReserved": "2025-03-21T21:15:19.488Z",
    "dateUpdated": "2025-07-23T20:10:00.301Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10496 (GCVE-0-2024-10496)
Vulnerability from cvelistv5
Published
2024-12-10 15:55
Modified
2024-12-10 20:10
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.3
Version: 23.0    23.3.4
Version: 24.0    224.3.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10496",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-10T20:10:39.011562Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-10T20:10:51.547Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.4",
              "status": "affected",
              "version": "23.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "224.3.1",
              "status": "affected",
              "version": "24.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T15:55:46.698Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview-.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of bounds read in BuildFontMap in fontmgr.cpp in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-10496",
    "datePublished": "2024-12-10T15:55:46.698Z",
    "dateReserved": "2024-10-29T14:41:29.031Z",
    "dateUpdated": "2024-12-10T20:10:51.547Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-23612 (GCVE-0-2024-23612)
Vulnerability from cvelistv5
Published
2024-03-11 15:19
Modified
2024-10-10 20:30
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:06:25.270Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "2024_q1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-23612",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-11T17:03:56.780213Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T18:42:00.511Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "2024 Q1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn improper error handling vulnerability in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "An improper error handling vulnerability in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-10T20:30:00.781Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Error Handling Issue in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-23612",
    "datePublished": "2024-03-11T15:19:34.788Z",
    "dateReserved": "2024-01-18T20:48:24.221Z",
    "dateUpdated": "2024-10-10T20:30:00.781Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10495 (GCVE-0-2024-10495)
Vulnerability from cvelistv5
Published
2024-12-10 15:52
Modified
2024-12-10 20:18
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.3
Version: 23.0    23.3.4
Version: 24.0    24.3.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10495",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-10T20:17:52.101424Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-10T20:18:12.830Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.4",
              "status": "affected",
              "version": "23.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.1",
              "status": "affected",
              "version": "24.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T15:52:43.177Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview-.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of bounds read when loading the font table in fontmgr.cpp in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-10495",
    "datePublished": "2024-12-10T15:52:43.177Z",
    "dateReserved": "2024-10-29T14:41:27.738Z",
    "dateUpdated": "2024-12-10T20:18:12.830Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2631 (GCVE-0-2025-2631)
Vulnerability from cvelistv5
Published
2025-04-09 19:10
Modified
2025-04-09 19:32
CWE
Summary
Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW in InitCPUInformation() that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   
Version: 23.1.0   
Version: 24.1.0   
Version: 25.1.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2631",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T19:32:31.686691Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T19:32:46.740Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "MacOS",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThan": "22.3.4",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.3.5",
              "status": "affected",
              "version": "23.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.3.2",
              "status": "affected",
              "version": "24.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.1.1",
              "status": "affected",
              "version": "25.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eOut of bounds write vulnerability due to improper bounds checking in NI LabVIEW in InitCPUInformation() that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW in InitCPUInformation() that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T19:10:22.077Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Write Vulnerability in NI LabVIEW in InitCPUInformation()",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-2631",
    "datePublished": "2025-04-09T19:10:22.077Z",
    "dateReserved": "2025-03-21T21:12:45.558Z",
    "dateUpdated": "2025-04-09T19:32:46.740Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2633 (GCVE-0-2025-2633)
Vulnerability from cvelistv5
Published
2025-07-23 15:49
Modified
2025-07-23 17:23
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.5
Version: 23.0.0    23.3.6
Version: 24.0.0    24.3.3
Version: 25.0.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2633",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T17:23:47.897012Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T17:23:55.255Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eOut of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-23T15:49:06.836Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Read Vulnerability in NI LabVIEW when loading fonts",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-2633",
    "datePublished": "2025-07-23T15:49:06.836Z",
    "dateReserved": "2025-03-21T21:15:17.811Z",
    "dateUpdated": "2025-07-23T17:23:55.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-23611 (GCVE-0-2024-23611)
Vulnerability from cvelistv5
Published
2024-03-11 15:14
Modified
2024-08-28 19:57
CWE
Summary
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:06:25.313Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "2024 Q1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-23611",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-28T19:56:16.752194Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T19:57:08.855Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "2024 Q1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-11T15:14:22.944Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Write Due to Missing Bounds Check in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-23611",
    "datePublished": "2024-03-11T15:14:22.944Z",
    "dateReserved": "2024-01-18T20:48:24.220Z",
    "dateUpdated": "2024-08-28T19:57:08.855Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7849 (GCVE-0-2025-7849)
Vulnerability from cvelistv5
Published
2025-07-29 21:27
Modified
2025-08-02 03:55
CWE
Summary
A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.5
Version: 23.0.0    23.3.6
Version: 24.0.0    24.3.3
Version: 25.0.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7849",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-01T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-02T03:55:48.802Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Rocco Calvi (@TecR0c) with TecSecurity working with Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-29T21:27:20.080Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Memory Corruption Issue in NI LabVIEW due to improper error handling",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-7849",
    "datePublished": "2025-07-29T21:27:20.080Z",
    "dateReserved": "2025-07-18T21:43:09.001Z",
    "dateUpdated": "2025-08-02T03:55:48.802Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-23610 (GCVE-0-2024-23610)
Vulnerability from cvelistv5
Published
2024-03-11 15:12
Modified
2024-08-08 15:09
CWE
Summary
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:06:25.334Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThan": "2024_q1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-23610",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-11T18:00:42.020382Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-08T15:09:09.675Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "2024 Q1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-11T15:12:33.108Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Write Due to Missing Bounds Check in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-23610",
    "datePublished": "2024-03-11T15:12:33.108Z",
    "dateReserved": "2024-01-18T20:48:24.220Z",
    "dateUpdated": "2024-08-08T15:09:09.675Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4079 (GCVE-0-2024-4079)
Vulnerability from cvelistv5
Published
2024-07-23 13:19
Modified
2025-05-01 03:55
CWE
Summary
An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    24.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "24.1",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4079",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "manipulation"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-01T03:55:26.917Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:51.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "24.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T13:19:35.141Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Read Due to Missing Bounds Check in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-4079",
    "datePublished": "2024-07-23T13:19:35.141Z",
    "dateReserved": "2024-04-23T15:11:16.465Z",
    "dateUpdated": "2025-05-01T03:55:26.917Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-5023 (GCVE-0-2013-5023)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
CWE
  • n/a
Summary
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:59:41.216Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-05-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-09-17T09:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-5023",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument"
            },
            {
              "name": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument"
            },
            {
              "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-5023",
    "datePublished": "2013-08-06T18:00:00",
    "dateReserved": "2013-07-31T00:00:00",
    "dateUpdated": "2024-08-06T16:59:41.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10494 (GCVE-0-2024-10494)
Vulnerability from cvelistv5
Published
2024-12-10 15:49
Modified
2024-12-10 20:33
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    22.3.3
Version: 23.0    23.3.4
Version: 24.0    24.3.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10494",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-10T20:33:02.416517Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-10T20:33:18.417Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.4",
              "status": "affected",
              "version": "23.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.1",
              "status": "affected",
              "version": "24.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q3 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T15:49:13.763Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-vulnerabilities-in-ni-labview-.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of bounds read in HeapObjMapImpl.cpp in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-10494",
    "datePublished": "2024-12-10T15:49:13.763Z",
    "dateReserved": "2024-10-29T14:41:26.180Z",
    "dateUpdated": "2024-12-10T20:33:18.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-23608 (GCVE-0-2024-23608)
Vulnerability from cvelistv5
Published
2024-03-11 15:10
Modified
2024-08-22 19:05
CWE
Summary
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:06:25.252Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "2024.q1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-23608",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-12T15:49:44.382794Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-22T19:05:18.989Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "2024 Q1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-11T15:10:16.963Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-due-to-missing-bounds-check-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Write Due to Missing Bounds Check in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-23608",
    "datePublished": "2024-03-11T15:10:16.963Z",
    "dateReserved": "2024-01-18T20:48:24.220Z",
    "dateUpdated": "2024-08-22T19:05:18.989Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-23609 (GCVE-0-2024-23609)
Vulnerability from cvelistv5
Published
2024-03-11 15:17
Modified
2025-04-16 15:48
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Summary
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "2024_q1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-23609",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-12T14:41:18.930345Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T15:48:24.638Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:06:25.333Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "2024 Q1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn improper error handling vulnerability in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "An improper error handling vulnerability in LabVIEW may result in remote code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-10T20:29:07.987Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/improper-error-handling-issues-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper Error Handling Issue in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-23609",
    "datePublished": "2024-03-11T15:17:59.351Z",
    "dateReserved": "2024-01-18T20:48:24.220Z",
    "dateUpdated": "2025-04-16T15:48:24.638Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4080 (GCVE-0-2024-4080)
Vulnerability from cvelistv5
Published
2024-07-23 13:29
Modified
2025-05-01 03:55
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    24.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "24.1",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4080",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "manipulation"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-01T03:55:27.216Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:51.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "24.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-14",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-14 Client-side Injection-induced Buffer Overflow"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T13:29:55.012Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Memory Corruption Due to Improper Length Checks in LabVIEW tdcore.dll",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-4080",
    "datePublished": "2024-07-23T13:29:55.012Z",
    "dateReserved": "2024-04-23T15:11:19.355Z",
    "dateUpdated": "2025-05-01T03:55:27.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2629 (GCVE-0-2025-2629)
Vulnerability from cvelistv5
Published
2025-04-09 18:45
Modified
2025-04-09 18:58
CWE
  • CWE-427 - Uncontrolled Search Path Element
Summary
There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW when loading NI Error Reporting. This vulnerability may result in arbitrary code execution. Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   
Version: 23.1.0   
Version: 24.1.0
Version: 25.1.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2629",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T18:58:34.817569Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T18:58:49.944Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThan": "22.3.4",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "223.3.5",
              "status": "affected",
              "version": "23.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.3.2",
              "status": "affected",
              "version": "24.1.0",
              "versionType": "sem"
            },
            {
              "lessThan": "25.1.1",
              "status": "affected",
              "version": "25.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Mike Palafox from BLOOMY\u00ae"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThere is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW when loading NI Error Reporting.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW when loading NI Error Reporting.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-471",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-471 Search Order Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427 Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T18:45:35.434Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/dll-hijacking-vulnerability-in-ni-labview-when-loading-ni-error-reporting.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "DLL Hijacking Vulnerability in NI LabVIEW When Loading NI Error Reporting",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-2629",
    "datePublished": "2025-04-09T18:45:35.434Z",
    "dateReserved": "2025-03-21T21:07:28.841Z",
    "dateUpdated": "2025-04-09T18:58:49.944Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4081 (GCVE-0-2024-4081)
Vulnerability from cvelistv5
Published
2024-07-23 13:32
Modified
2025-05-01 03:55
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "24.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4081",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "manipulation"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-01T03:55:27.540Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "24.1",
              "status": "affected",
              "version": "0",
              "versionType": "sem"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-14",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-14 Client-side Injection-induced Buffer Overflow"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T13:32:52.584Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-issues-due-to-improper-length-checks-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Memory Corruption Due to Improper Length Check in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-4081",
    "datePublished": "2024-07-23T13:32:52.584Z",
    "dateReserved": "2024-04-23T15:11:21.056Z",
    "dateUpdated": "2025-05-01T03:55:27.540Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-2775 (GCVE-0-2017-2775)
Vulnerability from cvelistv5
Published
2017-03-31 18:00
Modified
2024-08-05 14:02
CWE
  • remote code execution
Summary
An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabVIEW before 2015 SP1 f7 Patch and 2016 before f2 Patch. A specially crafted VI file can cause a user controlled value to be used as a loop terminator resulting in internal heap corruption. An attacker controlled VI file can be used to trigger this vulnerability, exploitation could lead to remote code execution.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.786Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97020",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97020"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.talosintelligence.com/reports/TALOS-2017-0269/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.ni.com/product-documentation/53778/en/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LabVIEW 2016 Evaluation",
          "vendor": "National Instruments",
          "versions": [
            {
              "status": "affected",
              "version": "16.0.0.49152"
            }
          ]
        }
      ],
      "datePublic": "2017-03-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabVIEW before 2015 SP1 f7 Patch and 2016 before f2 Patch. A specially crafted VI file can cause a user controlled value to be used as a loop terminator resulting in internal heap corruption. An attacker controlled VI file can be used to trigger this vulnerability, exploitation could lead to remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote code execution",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T18:21:55",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "97020",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97020"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.talosintelligence.com/reports/TALOS-2017-0269/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.ni.com/product-documentation/53778/en/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2017-2775",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LabVIEW 2016 Evaluation",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "16.0.0.49152"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "National Instruments"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabVIEW before 2015 SP1 f7 Patch and 2016 before f2 Patch. A specially crafted VI file can cause a user controlled value to be used as a loop terminator resulting in internal heap corruption. An attacker controlled VI file can be used to trigger this vulnerability, exploitation could lead to remote code execution."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote code execution"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97020",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97020"
            },
            {
              "name": "http://www.talosintelligence.com/reports/TALOS-2017-0269/",
              "refsource": "MISC",
              "url": "http://www.talosintelligence.com/reports/TALOS-2017-0269/"
            },
            {
              "name": "http://www.ni.com/product-documentation/53778/en/",
              "refsource": "CONFIRM",
              "url": "http://www.ni.com/product-documentation/53778/en/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2017-2775",
    "datePublished": "2017-03-31T18:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-08-05T14:02:07.786Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-2779 (GCVE-0-2017-2779)
Vulnerability from cvelistv5
Published
2017-09-05 18:00
Modified
2024-09-16 23:06
CWE
  • remote code execution
Summary
An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.673Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100519",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100519"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://0patch.blogspot.com/2017/09/0patching-rsrc-arbitrary-null-write.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0273"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.ni.com/product-documentation/54099/en/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LabVIEW 2016",
          "vendor": "National Instruments",
          "versions": [
            {
              "status": "affected",
              "version": "16.0"
            }
          ]
        }
      ],
      "datePublic": "2017-08-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote code execution",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T18:21:58",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "100519",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100519"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://0patch.blogspot.com/2017/09/0patching-rsrc-arbitrary-null-write.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0273"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.ni.com/product-documentation/54099/en/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2017-08-29T00:00:00",
          "ID": "CVE-2017-2779",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LabVIEW 2016",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "16.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "National Instruments"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW 2016, LabVIEW 2015, and LabVIEW 2014. A specially crafted Virtual Instrument (VI) file can cause an attacker controlled looping condition resulting in an arbitrary null write. An attacker controlled VI file can be used to trigger this vulnerability and can potentially result in code execution."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote code execution"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100519",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100519"
            },
            {
              "name": "https://0patch.blogspot.com/2017/09/0patching-rsrc-arbitrary-null-write.html",
              "refsource": "MISC",
              "url": "https://0patch.blogspot.com/2017/09/0patching-rsrc-arbitrary-null-write.html"
            },
            {
              "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0273",
              "refsource": "MISC",
              "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0273"
            },
            {
              "name": "http://www.ni.com/product-documentation/54099/en/",
              "refsource": "CONFIRM",
              "url": "http://www.ni.com/product-documentation/54099/en/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2017-2779",
    "datePublished": "2017-09-05T18:00:00Z",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-16T23:06:16.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2632 (GCVE-0-2025-2632)
Vulnerability from cvelistv5
Published
2025-04-09 19:14
Modified
2025-04-09 19:32
CWE
Summary
Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW reading CPU info from cache that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   
Version: 23.1.0   
Version: 24.1.0   
Version: 25.1.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2632",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T19:31:48.381410Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T19:32:06.295Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows",
            "MacOS",
            "Linux"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThan": "22.3.4",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.3.5",
              "status": "affected",
              "version": "23.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "24.3.2",
              "status": "affected",
              "version": "24.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.1.1",
              "status": "affected",
              "version": "25.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eOut of bounds write vulnerability due to improper bounds checking in NI LabVIEW reading CPU info from cache that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW reading CPU info from cache that may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T19:14:00.977Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-write-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Write Vulnerability in NI LabVIEW reading CPU info from cache",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-2632",
    "datePublished": "2025-04-09T19:14:00.977Z",
    "dateReserved": "2025-03-21T21:12:47.036Z",
    "dateUpdated": "2025-04-09T19:32:06.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6638 (GCVE-0-2024-6638)
Vulnerability from cvelistv5
Published
2024-07-22 19:55
Modified
2024-08-01 21:41
CWE
  • CWE-190 - Integer Overflow or Wraparound
Summary
An integer overflow vulnerability due to improper input validation when reading TDMS files in LabVIEW may result in an infinite loop. Successful exploitation requires an attacker to provide a user with a specially crafted TDMS file. This vulnerability affects LabVIEW 2024 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0    24.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "24.1",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6638",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T14:13:58.614582Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T14:18:20.704Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:41:04.317Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/integer-overflow-vulnerability-reading-tdms-files-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "24.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "James McNally of Wiresmith Technology"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn integer overflow vulnerability due to improper input validation when reading TDMS files in LabVIEW may result in an infinite loop.  Successful exploitation requires an attacker to provide a user with a specially crafted TDMS file.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An integer overflow vulnerability due to improper input validation when reading TDMS files in LabVIEW may result in an infinite loop.  Successful exploitation requires an attacker to provide a user with a specially crafted TDMS file.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-92",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-92 Forced Integer Overflow"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190 Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-22T19:55:23.548Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/integer-overflow-vulnerability-reading-tdms-files-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Integer Overflow Vulnerability Reading TDMS Files in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-6638",
    "datePublished": "2024-07-22T19:55:23.548Z",
    "dateReserved": "2024-07-09T23:58:45.236Z",
    "dateUpdated": "2024-08-01T21:41:04.317Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2630 (GCVE-0-2025-2630)
Vulnerability from cvelistv5
Published
2025-04-09 18:50
Modified
2025-04-09 18:57
CWE
  • CWE-427 - Uncontrolled Search Path Element
Summary
There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW. This vulnerability may result in arbitrary code execution. Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
Impacted products
Vendor Product Version
NI LabVIEW Version: 0   
Version: 23.1.0   
Version: 24.1.0   
Version: 25.1.0   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2630",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T18:57:32.231305Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T18:57:44.369Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThan": "22.3.4",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "23.3.5",
              "status": "affected",
              "version": "23.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "224.3.2",
              "status": "affected",
              "version": "24.1.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.1.1",
              "status": "affected",
              "version": "25.1.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Mike Palafox from BLOOMY\u00ae"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThere is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "There is a DLL hijacking vulnerability due to an uncontrolled search path that exists in NI LabVIEW.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to insert a malicious DLL into the uncontrolled search path.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-471",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-471 Search Order Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427 Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T18:50:05.849Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/dll-hijacking-vulnerability-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "DLL Hijacking Vulnerability in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-2630",
    "datePublished": "2025-04-09T18:50:05.849Z",
    "dateReserved": "2025-03-21T21:07:31.428Z",
    "dateUpdated": "2025-04-09T18:57:44.369Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-5022 (GCVE-0-2013-5022)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
CWE
  • n/a
Summary
Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:59:41.206Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-05-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-09-17T09:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-5022",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument"
            },
            {
              "name": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument"
            },
            {
              "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument",
              "refsource": "CONFIRM",
              "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-5022",
    "datePublished": "2013-08-06T18:00:00",
    "dateReserved": "2013-07-31T00:00:00",
    "dateUpdated": "2024-08-06T16:59:41.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}