Vulnerabilites related to MOXA - NPort IAW5000A-I/O
CVE-2020-25192 (GCVE-0-2020-25192)
Vulnerability from cvelistv5
Published
2020-12-23 14:08
Modified
2024-09-16 22:41
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
MOXA | NPort IAW5000A-I/O |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:26:10.247Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NPort IAW5000A-I/O", "vendor": "MOXA", "versions": [ { "lessThanOrEqual": "Version 2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "datePublic": "2020-10-13T00:00:00", "descriptions": [ { "lang": "en", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-23T14:08:28", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "solutions": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" }, "title": "MOXA NPort IAW5000A-I/O Series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-10-13T00:00:00.000Z", "ID": "CVE-2020-25192", "STATE": "PUBLIC", "TITLE": "MOXA NPort IAW5000A-I/O Series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NPort IAW5000A-I/O", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.1" } ] } } ] }, "vendor_name": "MOXA" } ] } }, "credit": [ { "lang": "eng", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ] }, "solution": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25192", "datePublished": "2020-12-23T14:08:28.438482Z", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-09-16T22:41:28.665Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-25153 (GCVE-0-2020-25153)
Vulnerability from cvelistv5
Published
2020-12-23 14:08
Modified
2024-09-16 19:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-521 - Weak Password Requirements
Summary
The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
MOXA | NPort IAW5000A-I/O |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:26:09.633Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NPort IAW5000A-I/O", "vendor": "MOXA", "versions": [ { "lessThanOrEqual": "Version 2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "datePublic": "2020-10-13T00:00:00", "descriptions": [ { "lang": "en", "value": "The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-521", "description": "CWE-521: Weak Password Requirements", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-23T14:08:34", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "solutions": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" }, "title": "MOXA NPort IAW5000A-I/O Series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-10-13T00:00:00.000Z", "ID": "CVE-2020-25153", "STATE": "PUBLIC", "TITLE": "MOXA NPort IAW5000A-I/O Series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NPort IAW5000A-I/O", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.1" } ] } } ] }, "vendor_name": "MOXA" } ] } }, "credit": [ { "lang": "eng", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-521: Weak Password Requirements" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ] }, "solution": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25153", "datePublished": "2020-12-23T14:08:34.327193Z", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-09-16T19:35:37.248Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-25190 (GCVE-0-2020-25190)
Vulnerability from cvelistv5
Published
2020-12-23 14:07
Modified
2024-09-16 21:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Summary
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
MOXA | NPort IAW5000A-I/O |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:26:09.939Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NPort IAW5000A-I/O", "vendor": "MOXA", "versions": [ { "lessThanOrEqual": "Version 2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "datePublic": "2020-10-13T00:00:00", "descriptions": [ { "lang": "en", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-23T14:07:56", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "solutions": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" }, "title": "MOXA NPort IAW5000A-I/O Series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-10-13T00:00:00.000Z", "ID": "CVE-2020-25190", "STATE": "PUBLIC", "TITLE": "MOXA NPort IAW5000A-I/O Series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NPort IAW5000A-I/O", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.1" } ] } } ] }, "vendor_name": "MOXA" } ] } }, "credit": [ { "lang": "eng", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319: Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ] }, "solution": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25190", "datePublished": "2020-12-23T14:07:56.166255Z", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-09-16T21:08:02.611Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-25194 (GCVE-0-2020-25194)
Vulnerability from cvelistv5
Published
2020-12-23 14:08
Modified
2024-09-16 18:29
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-269 - Improper Privilege Management
Summary
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
MOXA | NPort IAW5000A-I/O |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:26:10.096Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NPort IAW5000A-I/O", "vendor": "MOXA", "versions": [ { "lessThanOrEqual": "Version 2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "datePublic": "2020-10-13T00:00:00", "descriptions": [ { "lang": "en", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-269", "description": "CWE-269: Improper Privilege Management", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-23T14:08:17", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "solutions": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" }, "title": "MOXA NPort IAW5000A-I/O Series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-10-13T00:00:00.000Z", "ID": "CVE-2020-25194", "STATE": "PUBLIC", "TITLE": "MOXA NPort IAW5000A-I/O Series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NPort IAW5000A-I/O", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.1" } ] } } ] }, "vendor_name": "MOXA" } ] } }, "credit": [ { "lang": "eng", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-269: Improper Privilege Management" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ] }, "solution": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25194", "datePublished": "2020-12-23T14:08:17.398380Z", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-09-16T18:29:02.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-25196 (GCVE-0-2020-25196)
Vulnerability from cvelistv5
Published
2020-12-23 14:08
Modified
2024-09-17 00:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
MOXA | NPort IAW5000A-I/O |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:33:04.375Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NPort IAW5000A-I/O", "vendor": "MOXA", "versions": [ { "lessThanOrEqual": "Version 2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "datePublic": "2020-10-13T00:00:00", "descriptions": [ { "lang": "en", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-307", "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-23T14:08:41", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "solutions": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" }, "title": "MOXA NPort IAW5000A-I/O Series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-10-13T00:00:00.000Z", "ID": "CVE-2020-25196", "STATE": "PUBLIC", "TITLE": "MOXA NPort IAW5000A-I/O Series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NPort IAW5000A-I/O", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.1" } ] } } ] }, "vendor_name": "MOXA" } ] } }, "credit": [ { "lang": "eng", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-307: Improper Restriction of Excessive Authentication Attempts" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ] }, "solution": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25196", "datePublished": "2020-12-23T14:08:41.583756Z", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-09-17T00:37:03.186Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-25198 (GCVE-0-2020-25198)
Vulnerability from cvelistv5
Published
2020-12-23 14:08
Modified
2024-09-17 00:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-384 - Session Fixation
Summary
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user’s cookies.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
MOXA | NPort IAW5000A-I/O |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:33:04.438Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NPort IAW5000A-I/O", "vendor": "MOXA", "versions": [ { "lessThanOrEqual": "Version 2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "datePublic": "2020-10-13T00:00:00", "descriptions": [ { "lang": "en", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user\u2019s cookies." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-384", "description": "CWE-384 Session Fixation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-23T14:08:23", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ], "solutions": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" }, "title": "MOXA NPort IAW5000A-I/O Series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-10-13T00:00:00.000Z", "ID": "CVE-2020-25198", "STATE": "PUBLIC", "TITLE": "MOXA NPort IAW5000A-I/O Series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NPort IAW5000A-I/O", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.1" } ] } } ] }, "vendor_name": "MOXA" } ] } }, "credit": [ { "lang": "eng", "value": "Evgeniy Druzhinin and Ilya Karpov of Rostelecom-Solar reported these vulnerabilities to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user\u2019s cookies." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-384 Session Fixation" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-287-01" } ] }, "solution": [ { "lang": "en", "value": "Moxa has released an updated firmware version (https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=50535) for the NPort IAW5000A-I/O Series and recommends (https://www.moxa.com/en/support/support/security-advisory/nport-iaw5000a-io-serial-device-servers-vulnerabilities) users install this update on all affected systems." } ], "source": { "advisory": "ICSA-20-287-01 - MOXA NPort IAW5000A-I/O Series", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25198", "datePublished": "2020-12-23T14:08:23.404844Z", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-09-17T00:11:38.801Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }