Vulnerabilites related to moxa - sds-3008-t_firmware
CVE-2022-41312 (GCVE-0-2022-41312)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2025-03-25 14:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:42:44.840Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-41312", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-25T14:14:17.537478Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-25T14:14:23.557Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"Switch Description\", name \"switch_description\"" } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:03.117Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-41312", "datePublished": "2023-02-07T16:52:03.117Z", "dateReserved": "2022-09-21T20:50:07.445Z", "dateUpdated": "2025-03-25T14:14:23.557Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-41311 (GCVE-0-2022-41311)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2025-03-25 15:36
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text"
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:42:45.920Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-41311", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-25T15:36:14.814028Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-25T15:36:28.809Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"webLocationMessage_text\" name=\"webLocationMessage_text\"" } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:03.034Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-41311", "datePublished": "2023-02-07T16:52:03.034Z", "dateReserved": "2022-09-21T20:50:07.444Z", "dateUpdated": "2025-03-25T15:36:28.809Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-40691 (GCVE-0-2022-40691)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2024-08-03 12:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Information Exposure
Summary
An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:21:46.623Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1621" }, { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sds-3008_firmware", "vendor": "moxa", "versions": [ { "lessThanOrEqual": "2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sds-3008-t_firmware", "vendor": "moxa", "versions": [ { "lessThanOrEqual": "2.1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2022-40691", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-01T17:20:38.057437Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T17:26:19.735Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:02.533Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-40691", "datePublished": "2023-02-07T16:52:02.533Z", "dateReserved": "2022-09-21T20:53:42.822Z", "dateUpdated": "2024-08-03T12:21:46.623Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-40693 (GCVE-0-2022-40693)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2024-08-03 12:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Summary
A cleartext transmission vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:21:46.601Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1616" }, { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-40693", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-01T15:48:00.655638Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T15:49:15.722Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A cleartext transmission vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:04.022Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-40693", "datePublished": "2023-02-07T16:52:04.022Z", "dateReserved": "2022-09-20T20:07:00.466Z", "dateUpdated": "2024-08-03T12:21:46.601Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-41313 (GCVE-0-2022-41313)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2025-03-25 14:13
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact"
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:42:44.647Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-41313", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-25T14:13:37.434375Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-25T14:13:43.703Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"switch_contact\"" } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:03.195Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-41313", "datePublished": "2023-02-07T16:52:03.195Z", "dateReserved": "2022-09-21T20:50:07.445Z", "dateUpdated": "2025-03-25T14:13:43.703Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-40224 (GCVE-0-2022-40224)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2025-03-05 19:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-410 - Insufficient Resource Pool
Summary
A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP message header can lead to denial of service. An attacker can send an HTTP request to trigger this vulnerability.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:14:40.040Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1618" }, { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-40224", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-05T18:43:09.372564Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-05T19:27:11.797Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP message header can lead to denial of service. An attacker can send an HTTP request to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-410", "description": "CWE-410: Insufficient Resource Pool", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:03.607Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-40224", "datePublished": "2023-02-07T16:52:03.607Z", "dateReserved": "2022-09-21T17:34:10.101Z", "dateUpdated": "2025-03-05T19:27:11.797Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2023-02-07 17:15
Modified
2024-11-21 07:21
Severity ?
Summary
A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP message header can lead to denial of service. An attacker can send an HTTP request to trigger this vulnerability.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618 | Exploit, Technical Description, Third Party Advisory | |
talos-cna@cisco.com | https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1618 |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
moxa | sds-3008_firmware | * | |
moxa | sds-3008 | - | |
moxa | sds-3008-t_firmware | * | |
moxa | sds-3008-t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*", "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP message header can lead to denial of service. An attacker can send an HTTP request to trigger this vulnerability." } ], "id": "CVE-2022-40224", "lastModified": "2024-11-21T07:21:06.107", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-07T17:15:10.003", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618" }, { "source": "talos-cna@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1618" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-410" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-07 17:15
Modified
2024-11-21 07:21
Severity ?
Summary
A cleartext transmission vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
moxa | sds-3008_firmware | * | |
moxa | sds-3008 | - | |
moxa | sds-3008-t_firmware | * | |
moxa | sds-3008-t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*", "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A cleartext transmission vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability." } ], "id": "CVE-2022-40693", "lastModified": "2024-11-21T07:21:52.120", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-07T17:15:10.603", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616" }, { "source": "talos-cna@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1616" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-07 17:15
Modified
2024-11-21 07:23
Severity ?
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text"
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
moxa | sds-3008_firmware | * | |
moxa | sds-3008 | - | |
moxa | sds-3008-t_firmware | * | |
moxa | sds-3008-t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*", "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"webLocationMessage_text\" name=\"webLocationMessage_text\"" } ], "id": "CVE-2022-41311", "lastModified": "2024-11-21T07:23:01.267", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.4, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-07T17:15:10.930", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "source": "talos-cna@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-07 17:15
Modified
2024-11-21 07:23
Severity ?
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact"
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 | Exploit, Technical Description, Third Party Advisory | |
talos-cna@cisco.com | https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
moxa | sds-3008_firmware | * | |
moxa | sds-3008 | - | |
moxa | sds-3008-t_firmware | * | |
moxa | sds-3008-t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*", "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"switch_contact\"" } ], "id": "CVE-2022-41313", "lastModified": "2024-11-21T07:23:01.527", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.4, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-07T17:15:11.477", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "source": "talos-cna@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-07 17:15
Modified
2024-11-21 07:21
Severity ?
Summary
An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
moxa | sds-3008_firmware | * | |
moxa | sds-3008 | - | |
moxa | sds-3008-t_firmware | * | |
moxa | sds-3008-t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*", "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability." } ], "id": "CVE-2022-40691", "lastModified": "2024-11-21T07:21:51.850", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-07T17:15:10.330", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621" }, { "source": "talos-cna@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1621" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-07 17:15
Modified
2024-11-21 07:23
Severity ?
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 | Exploit, Technical Description, Third Party Advisory | |
talos-cna@cisco.com | https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
moxa | sds-3008_firmware | * | |
moxa | sds-3008 | - | |
moxa | sds-3008-t_firmware | * | |
moxa | sds-3008-t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*", "matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726", "versionEndIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*", "matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"Switch Description\", name \"switch_description\"" } ], "id": "CVE-2022-41312", "lastModified": "2024-11-21T07:23:01.400", "metrics": { "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 0.9, "impactScore": 3.4, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-07T17:15:11.200", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "source": "talos-cna@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }