CVE-2022-41312 (GCVE-0-2022-41312)
Vulnerability from cvelistv5
Published
2023-02-07 16:52
Modified
2025-03-25 14:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"
References
► | URL | Tags | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Moxa | SDS-3008 Series Industrial Ethernet Switch |
Version: 2.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:42:44.840Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "tags": [ "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "tags": [ "x_transferred" ], "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-41312", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-25T14:14:17.537478Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-25T14:14:23.557Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "SDS-3008 Series Industrial Ethernet Switch", "vendor": "Moxa", "versions": [ { "status": "affected", "version": "2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\"Switch Description\", name \"switch_description\"" } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-07T16:52:03.117Z", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619" }, { "name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities", "url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities" } ] } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2022-41312", "datePublished": "2023-02-07T16:52:03.117Z", "dateReserved": "2022-09-21T20:50:07.445Z", "dateUpdated": "2025-03-25T14:14:23.557Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-41312\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2023-02-07T17:15:11.200\",\"lastModified\":\"2024-11-21T07:23:01.400\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\\\"Switch Description\\\", name \\\"switch_description\\\"\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.9,\"impactScore\":3.4}]},\"weaknesses\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.1\",\"matchCriteriaId\":\"DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07865F6F-F008-48BB-8FAE-CC397042F4B9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.1\",\"matchCriteriaId\":\"B751F6A7-8555-4080-B278-D7A4E982F726\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C49175C2-3568-43F5-B75F-E89E3BB41190\"}]}]}],\"references\":[{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Technical Description\",\"Third Party Advisory\"]},{\"url\":\"https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Technical Description\",\"Third Party Advisory\"]},{\"url\":\"https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619\", \"name\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities\", \"name\": \"https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T12:42:44.840Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-41312\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-25T14:14:17.537478Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-25T14:14:11.021Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_0\": {\"scope\": \"UNCHANGED\", \"version\": \"3.0\", \"baseScore\": 4.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Moxa\", \"product\": \"SDS-3008 Series Industrial Ethernet Switch\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.1\"}]}], \"references\": [{\"url\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619\", \"name\": \"https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619\"}, {\"url\": \"https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities\", \"name\": \"https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id=\\\"Switch Description\\\", name \\\"switch_description\\\"\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b\", \"shortName\": \"talos\", \"dateUpdated\": \"2023-02-07T16:52:03.117Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-41312\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-25T14:14:23.557Z\", \"dateReserved\": \"2022-09-21T20:50:07.445Z\", \"assignerOrgId\": \"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b\", \"datePublished\": \"2023-02-07T16:52:03.117Z\", \"assignerShortName\": \"talos\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…