Vulnerabilites related to siemens - sicam_t_firmware
CVE-2020-10044 (GCVE-0-2020-10044)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.807Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:05", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10044", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10044", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.807Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10037 (GCVE-0-2020-10037)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - Out-of-bounds Read
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.769Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10037", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10037", "datePublished": "2020-07-14T13:18:04", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.769Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10042 (GCVE-0-2020-10042)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.347Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:05", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10042", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10042", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.347Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10041 (GCVE-0-2020-10041)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.873Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:05", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10041", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10041", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.873Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10038 (GCVE-0-2020-10038)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.789Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the device\u0027s web server might be able to execute administrative commands without authentication." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10038", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the device\u0027s web server might be able to execute administrative commands without authentication." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10038", "datePublished": "2020-07-14T13:18:04", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.789Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10039 (GCVE-0-2020-10039)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.303Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311: Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10039", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10039", "datePublished": "2020-07-14T13:18:04", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.303Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10045 (GCVE-0-2020-10045)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-294 - Authentication Bypass by Capture-replay
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.932Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-294", "description": "CWE-294: Authentication Bypass by Capture-replay", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:05", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10045", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-294: Authentication Bypass by Capture-replay" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10045", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.932Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10043 (GCVE-0-2020-10043)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.402Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-80", "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:05", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10043", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10043", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.402Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-10040 (GCVE-0-2020-10040)
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 10:50
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-916 - Use of Password Hash With Insufficient Computational Effort
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.835Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-916", "description": "CWE-916: Use of Password Hash With Insufficient Computational Effort", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10040", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-916: Use of Password Hash With Insufficient Computational Effort" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10040", "datePublished": "2020-07-14T13:18:04", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.835Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un atacante con acceso a la red podr\u00eda ser capaz de instalar un firmware especialmente dise\u00f1ado en el dispositivo" } ], "id": "CVE-2020-10044", "lastModified": "2024-11-21T04:54:41.973", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:17.027", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un atacante en una posici\u00f3n de red privilegiada entre un usuario leg\u00edtimo y el servidor web podr\u00eda ser capaz de conducir un ataque de tipo Man-in-the-middle y conseguir acceso de lectura y escritura a los datos transmitidos" } ], "id": "CVE-2020-10039", "lastModified": "2024-11-21T04:54:41.423", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.620", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the device\u0027s web server might be able to execute administrative commands without authentication." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un atacante con acceso al servidor web del dispositivo podr\u00eda ser capaz de ejecutar comandos administrativos sin autenticaci\u00f3n" } ], "id": "CVE-2020-10038", "lastModified": "2024-11-21T04:54:41.313", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.540", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Al llevar a cabo un ataque de inundaci\u00f3n contra el servidor web, un atacante podr\u00eda ser capaz de conseguir acceso de lectura a la memoria del dispositivo, revelando posiblemente informaci\u00f3n confidencial" } ], "id": "CVE-2020-10037", "lastModified": "2024-11-21T04:54:41.200", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.463", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un error en el procedimiento de la respuesta de desaf\u00edo podr\u00eda permitir a un atacante reproducir el tr\u00e1fico de autenticaci\u00f3n y conseguir acceso a \u00e1reas protegidas de la aplicaci\u00f3n web" } ], "id": "CVE-2020-10045", "lastModified": "2024-11-21T04:54:42.080", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:17.120", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-294" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-294" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). A buffer overflow in various positions of the web application might enable an attacker with access to the web application to execute arbitrary code over the network." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un desbordamiento del b\u00fafer en varias posiciones de la aplicaci\u00f3n web podr\u00eda ser capaz de permitir a un atacante con acceso a la aplicaci\u00f3n web ejecutar c\u00f3digo arbitrario a trav\u00e9s de la red" } ], "id": "CVE-2020-10042", "lastModified": "2024-11-21T04:54:41.753", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.853", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). El servidor web podr\u00eda permitir ataques de tipo Cross-Site Scripting (XSS) si los usuarios desprevenidos son enga\u00f1ados para acceder a un enlace malicioso" } ], "id": "CVE-2020-10043", "lastModified": "2024-11-21T04:54:41.867", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.917", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-80" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Una vulnerabilidad de tipo Cross-Site-Scripting (XSS) almacenado est\u00e1 presente en diferentes ubicaciones de la aplicaci\u00f3n web. Un atacante podr\u00eda ser capaz de tomar el control de una sesi\u00f3n de un usuario leg\u00edtimo" } ], "id": "CVE-2020-10041", "lastModified": "2024-11-21T04:54:41.643", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.777", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 04:54
Severity ?
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un atacante con acceso local al dispositivo podr\u00eda ser capaz de recuperar algunas contrase\u00f1as en texto sin cifrar" } ], "id": "CVE-2020-10040", "lastModified": "2024-11-21T04:54:41.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.697", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-916" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-916" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }