In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA8305E1-A2D7-4DBB-A5FB-E748E41FB060", "versionEndIncluding": "9.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\n\n\n\n\nIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.\n\n\n\n\n\n" } ], "id": "CVE-2023-32628", "lastModified": "2024-11-21T08:03:44.067", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-06T00:15:10.177", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-434" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-10 15:15
Modified
2024-11-21 06:07
Severity ?
Summary
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * | |
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F0F1E90-D14C-49A1-8EC2-3AF211C36FFF", "versionEndExcluding": "8.4.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "F748CA2A-6623-4D12-86E1-4F51FD9EA193", "versionEndExcluding": "9.0.1", "versionStartIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." }, { "lang": "es", "value": "El producto afectado es vulnerable a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria, que puede permitir a un atacante ejecutar remotamente c\u00f3digo arbitrario en el WebAccess/SCADA (WebAccess/SCADA versiones anteriores a 8.4.5, WebAccess/SCADA versiones anteriores a 9.0.1)" } ], "id": "CVE-2021-32943", "lastModified": "2024-11-21T06:07:58.570", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-10T15:15:07.700", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-12-19 18:29
Modified
2024-11-21 03:57
Severity ?
Summary
WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/106245 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.tenable.com/security/research/tra-2018-45 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106245 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2018-45 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 8.3.2 | |
microsoft | windows_server_2008 | r2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:8.3.2:*:*:*:*:*:*:*", "matchCriteriaId": "4FD6FF92-F296-4E92-9CB4-8D99F7651FE3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_server_2008:r2:sp1:*:*:*:*:*:*", "matchCriteriaId": "2ACA9287-B475-4AF7-A4DA-A7143CEF9E57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack." }, { "lang": "es", "value": "WebAccess/SCADA, WebAccess/SCADA en su versi\u00f3n 8.3.2 instalada en Windows 2008 R2 SP1. La falta de validaci\u00f3n adecuada de entradas proporcionadas por el usuario podr\u00eda permitir que un atacante provoque el desbordamiento de un b\u00fafer de la pila." } ], "id": "CVE-2018-18999", "lastModified": "2024-11-21T03:57:00.923", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-12-19T18:29:00.203", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106245" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106245" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2018-45" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-23 17:15
Modified
2024-11-21 05:17
Severity ?
Summary
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA569594-23AC-4389-BA15-7644D6FA8995", "versionEndExcluding": "9.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator." }, { "lang": "es", "value": "El componente WADashboard de WebAccess/SCADA Versiones 9.0 y anteriores, puede permitir a un atacante controlar o influir en una ruta usada en una operaci\u00f3n en el sistema de archivos y ejecutar c\u00f3digo remotamente como administrador" } ], "id": "CVE-2020-25161", "lastModified": "2024-11-21T05:17:30.647", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-23T17:15:13.270", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-73" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-610" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-18 14:15
Modified
2024-11-21 06:07
Severity ?
Summary
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D875587-E579-4333-AEE7-7434502B4057", "versionEndIncluding": "9.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system." }, { "lang": "es", "value": "Advantech WebAccess/SCADA Versiones 9.0.1 y anteriores, es vulnerable a un salto de directorio, que puede permitir a un atacante leer remotamente archivos arbitrarios en el sistema de archivos" } ], "id": "CVE-2021-32954", "lastModified": "2024-11-21T06:07:59.907", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "COMPLETE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-18T14:15:08.150", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-23" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-06 00:15
Modified
2024-11-21 07:44
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA8305E1-A2D7-4DBB-A5FB-E748E41FB060", "versionEndIncluding": "9.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\n\n\nIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.\n\n\n\n" } ], "id": "CVE-2023-22450", "lastModified": "2024-11-21T07:44:49.693", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-06T00:15:09.310", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-434" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-06-18 14:15
Modified
2024-11-21 06:08
Severity ?
Summary
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D875587-E579-4333-AEE7-7434502B4057", "versionEndIncluding": "9.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage." }, { "lang": "es", "value": "Advantech WebAccess/SCADA Versiones 9.0.1 y anteriores, es vulnerable a un redireccionamiento, que puede permitir a un atacante enviar una URL maliciosamente dise\u00f1ada que podr\u00eda resultar en redireccionar a un usuario a una p\u00e1gina web maliciosa" } ], "id": "CVE-2021-32956", "lastModified": "2024-11-21T06:08:00.143", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-18T14:15:08.273", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-601" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-17 19:15
Modified
2024-11-21 05:01
Severity ?
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 9.0.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:9.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "4E681B46-0DAF-40E9-B6EF-3FE30887B6F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de elevaci\u00f3n de privilegios local explotable en los permisos del sistema de archivos de la instalaci\u00f3n de Advantech WebAccess/SCADA versi\u00f3n 9.0.1.\u0026#xa0;En Run Key Privilege Escalation de webvrpcs en la carpeta de instalaci\u00f3n de WebAccess, un atacante puede reemplazar m\u00f3dulos binarios o cargados para ejecutar c\u00f3digo con privilegios NT SYSTEM" } ], "id": "CVE-2020-13553", "lastModified": "2024-11-21T05:01:29.047", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-17T19:15:12.510", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-02 23:15
Modified
2024-11-21 07:39
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "291FD4D3-18DC-4A9F-BF4C-CAF594A4669C", "versionEndExcluding": "9.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.\n\n" } ], "id": "CVE-2023-1437", "lastModified": "2024-11-21T07:39:11.140", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-02T23:15:10.153", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-822" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-06 00:15
Modified
2024-11-21 08:03
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA8305E1-A2D7-4DBB-A5FB-E748E41FB060", "versionEndIncluding": "9.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.\n\n" } ], "id": "CVE-2023-32540", "lastModified": "2024-11-21T08:03:33.563", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-06T00:15:10.067", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-94" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-02-05 21:29
Modified
2024-11-21 04:46
Severity ?
Summary
WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/106722 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106722 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 8.3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:8.3:*:*:*:*:*:*:*", "matchCriteriaId": "82006864-5296-4B38-A6D6-0C3EA2DB67F2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands." }, { "lang": "es", "value": "WebAccess/SCADA, en la versi\u00f3n 8.3, no sanea adecuadamente sus entradas para comandos SQL." } ], "id": "CVE-2019-6523", "lastModified": "2024-11-21T04:46:37.410", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-02-05T21:29:00.863", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106722" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106722" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-17 19:15
Modified
2024-11-21 05:01
Severity ?
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 9.0.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:9.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "4E681B46-0DAF-40E9-B6EF-3FE30887B6F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de elevaci\u00f3n de privilegios local explotable en los permisos del sistema de archivos de la instalaci\u00f3n de Advantech WebAccess/SCADA versi\u00f3n 9.0.1.\u0026#xa0;En la escalada de privilegios a trav\u00e9s de m\u00faltiples ejecutables de servicio en la carpeta de instalaci\u00f3n de WebAccess, un atacante puede reemplazar m\u00f3dulos binarios o cargados para ejecutar c\u00f3digo con privilegios NT SYSTEM" } ], "id": "CVE-2020-13552", "lastModified": "2024-11-21T05:01:28.920", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-17T19:15:12.450", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-10 15:15
Modified
2024-11-21 05:50
Severity ?
Summary
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * | |
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F0F1E90-D14C-49A1-8EC2-3AF211C36FFF", "versionEndExcluding": "8.4.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "F748CA2A-6623-4D12-86E1-4F51FD9EA193", "versionEndExcluding": "9.0.1", "versionStartIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." }, { "lang": "es", "value": "El archivo UserExcelOut.asp dentro de WebAccess/SCADA es vulnerable a un ataque de tipo cross-site scripting (XSS), que podr\u00eda permitir a un atacante enviar c\u00f3digo JavaScript malicioso. Esto podr\u00eda resultar en el secuestro de los tokens de cookies/sesi\u00f3n, la redirecci\u00f3n a una p\u00e1gina web maliciosa, y la acci\u00f3n involuntaria del navegador en el WebAccess/SCADA (WebAccess/SCADA versiones anteriores a 8.4.5, WebAccess/SCADA versiones anteriores a 9.0.1)" } ], "id": "CVE-2021-22676", "lastModified": "2024-11-21T05:50:27.487", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-10T15:15:07.457", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-10 14:15
Modified
2024-11-21 05:50
Severity ?
Summary
The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04 | Patch, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04 | Patch, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * | |
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F0F1E90-D14C-49A1-8EC2-3AF211C36FFF", "versionEndExcluding": "8.4.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "F748CA2A-6623-4D12-86E1-4F51FD9EA193", "versionEndExcluding": "9.0.1", "versionStartIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." }, { "lang": "es", "value": "El producto afectado es vulnerable a una condici\u00f3n de salto de ruta relativa, que puede permitir a un atacante acceder a archivos y directorios no autorizados en el WebAccess/SCADA (WebAccess/SCADA versiones anteriores a 8.4.5, WebAccess/SCADA versiones anteriores a 9.0.1)" } ], "id": "CVE-2021-22674", "lastModified": "2024-11-21T05:50:27.253", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-10T14:15:07.250", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-23" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-01-25 03:29
Modified
2024-11-21 04:08
Severity ?
Summary
A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/102781 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/102781 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8700AA2-B570-4648-AEB0-46AD318147A0", "versionEndExcluding": "8.2_20170817", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands." }, { "lang": "es", "value": "Se ha descubierto un problema de inyecci\u00f3n SQL en Advantech WebAccess/SCADA en versiones anteriores a la V8.2_20170817. WebAccess/SCADA no sanea adecuadamente sus entradas para comandos SQL." } ], "id": "CVE-2018-5443", "lastModified": "2024-11-21T04:08:48.940", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-01-25T03:29:00.320", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/102781" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/102781" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-89" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-02-05 21:29
Modified
2024-11-21 04:46
Severity ?
Summary
WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/106722 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106722 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 8.3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:8.3:*:*:*:*:*:*:*", "matchCriteriaId": "82006864-5296-4B38-A6D6-0C3EA2DB67F2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information." }, { "lang": "es", "value": "En la versi\u00f3n 8.3 de WebAccess/SCADA, peticiones especialmente manipuladas podr\u00edan permitir una omisi\u00f3n de autenticaci\u00f3n que podr\u00eda permitir que un atacante obtenga y manipule informaci\u00f3n sensible." } ], "id": "CVE-2019-6521", "lastModified": "2024-11-21T04:46:37.157", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 4.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-02-05T21:29:00.800", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106722" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106722" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-17 19:15
Modified
2024-11-21 05:01
Severity ?
Summary
A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168 | Exploit, Technical Description, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 9.0.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:9.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "4E681B46-0DAF-40E9-B6EF-3FE30887B6F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de inclusi\u00f3n de archivos locales en la funcionalidad de instalaci\u00f3n de Advantech WebAccess/SCADA versi\u00f3n 9.0.1.\u0026#xa0;Una aplicaci\u00f3n especialmente dise\u00f1ada puede conllevar a una divulgaci\u00f3n de informaci\u00f3n.\u0026#xa0;Un atacante puede enviar una petici\u00f3n HTTP autenticada para desencadenar esta vulnerabilidad" } ], "id": "CVE-2020-13550", "lastModified": "2024-11-21T05:01:28.670", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 3.1, "impactScore": 4.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 4.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-17T19:15:12.293", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-04-26 19:15
Modified
2024-11-21 05:50
Severity ?
Summary
Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D875587-E579-4333-AEE7-7434502B4057", "versionEndIncluding": "9.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Incorrect permissions are set to default on the \u2018Project Management\u2019 page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator\u2019s password and login as an administrator to escalate privileges on the system." }, { "lang": "es", "value": "Los permisos incorrectos son ajustados de forma predeterminada en la p\u00e1gina \"Project Management\" del portal WebAccess/SCADA de WebAccess/SCADA Versiones 9.0.1 y anteriores, lo que puede permitir a un usuario poco privilegiado actualizar la contrase\u00f1a de un administrador e iniciar sesi\u00f3n como administrador para escalar privilegios en el sistema" } ], "id": "CVE-2021-22669", "lastModified": "2024-11-21T05:50:26.640", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-04-26T19:15:08.417", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-17 19:15
Modified
2024-11-21 05:01
Severity ?
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 9.0.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:9.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "4E681B46-0DAF-40E9-B6EF-3FE30887B6F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de elevaci\u00f3n de privilegios local explotable en los permisos del sistema de archivos de la instalaci\u00f3n de Advantech WebAccess/SCADA versi\u00f3n 9.0.1.\u0026#xa0;En COM Server Application Privilege Escalation, un atacante puede reemplazar m\u00f3dulos binarios o cargados para ejecutar c\u00f3digo con privilegios NT SYSTEM" } ], "id": "CVE-2020-13555", "lastModified": "2024-11-21T05:01:29.303", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-17T19:15:12.590", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-02-17 19:15
Modified
2024-11-21 05:01
Severity ?
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Technical Description, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 9.0.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:9.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "4E681B46-0DAF-40E9-B6EF-3FE30887B6F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de elevaci\u00f3n de privilegios local explotable en los permisos del sistema de archivos de la instalaci\u00f3n de Advantech WebAccess/SCADA versi\u00f3n 9.0.1.\u0026#xa0;En la escalada de privilegios a trav\u00e9s del ejecutable PostgreSQL, un atacante puede reemplazar m\u00f3dulos binarios o cargados para ejecutar c\u00f3digo con privilegios NT SYSTEM" } ], "id": "CVE-2020-13551", "lastModified": "2024-11-21T05:01:28.800", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-17T19:15:12.387", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Technical Description", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-02-05 21:29
Modified
2024-11-21 04:46
Severity ?
Summary
WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/106722 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106722 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 8.3 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:8.3:*:*:*:*:*:*:*", "matchCriteriaId": "82006864-5296-4B38-A6D6-0C3EA2DB67F2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data." }, { "lang": "es", "value": "Existe una vulnerabilidad de autorizaci\u00f3n incorrecta en la versi\u00f3n 8.3 de WebAccess/SCADA que podr\u00eda permitir una omisi\u00f3n de autenticaci\u00f3n, permitiendo a un atacante subir datos maliciosos." } ], "id": "CVE-2019-6519", "lastModified": "2024-11-21T04:46:36.913", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-02-05T21:29:00.737", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106722" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/106722" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-18 22:15
Modified
2024-11-21 05:57
Severity ?
Summary
WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE952533-988E-4B44-8FD3-A29B53C1885A", "versionEndIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user\u2019s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions." }, { "lang": "es", "value": "WebAccess/SCADA versiones 9.0 y anteriores, son vulnerables a un ataque de tipo cross-site scripting, lo que puede permitir a un atacante enviar c\u00f3digo JavaScript malicioso a un usuario desprevenido, lo que podr\u00eda resultar en el secuestro de las cookies y tokens de sesi\u00f3n del usuario, redireccionando al usuario a una p\u00e1gina web maliciosa. y llevar a cabo acciones no deseadas del navegador" } ], "id": "CVE-2021-27436", "lastModified": "2024-11-21T05:57:59.240", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-18T22:15:13.617", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-01-25 03:29
Modified
2024-11-21 04:08
Severity ?
Summary
A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/102781 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/102781 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8700AA2-B570-4648-AEB0-46AD318147A0", "versionEndExcluding": "8.2_20170817", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device." }, { "lang": "es", "value": "Se ha descubierto un problema de salto de directorio en Advantech WebAccess/SCADA en versiones anteriores a la V8.2_20170817. Un atacante tiene acceso de lectura a archivos en la estructura de directorio del dispositivo objetivo." } ], "id": "CVE-2018-5445", "lastModified": "2024-11-21T04:08:49.057", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-01-25T03:29:00.367", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/102781" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/102781" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-03 17:15
Modified
2024-11-21 05:01
Severity ?
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
▶ | URL | Tags | |
---|---|---|---|
talos-cna@cisco.com | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
advantech | webaccess\/scada | 9.0.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:advantech:webaccess\\/scada:9.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "4E681B46-0DAF-40E9-B6EF-3FE30887B6F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de elevaci\u00f3n de privilegios local explotable en los permisos del sistema de archivos de la instalaci\u00f3n de Advantech WebAccess/SCADA versi\u00f3n 9.0.1.\u0026#xa0;En webvrpcs Run Key Privilege Escalation en la carpeta de instalaci\u00f3n de WebAccess, un atacante puede reemplazar m\u00f3dulos binarios o cargados para ejecutar c\u00f3digo con privilegios NT SYSTEM" } ], "id": "CVE-2020-13554", "lastModified": "2024-11-21T05:01:29.170", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.0, "impactScore": 6.0, "source": "talos-cna@cisco.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-03T17:15:11.487", "references": [ { "source": "talos-cna@cisco.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "sourceIdentifier": "talos-cna@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "talos-cna@cisco.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2021-22669 (GCVE-0-2021-22669)
Vulnerability from cvelistv5
Published
2021-04-26 18:59
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-732 - INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE
Summary
Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: WebAccess/SCADA Versions 9.0.1 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:06.922Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA Versions 9.0.1 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "Incorrect permissions are set to default on the \u2018Project Management\u2019 page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator\u2019s password and login as an administrator to escalate privileges on the system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-04-26T18:59:08", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-22669", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA Versions 9.0.1 and prior" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Incorrect permissions are set to default on the \u2018Project Management\u2019 page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator\u2019s password and login as an administrator to escalate privileges on the system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-22669", "datePublished": "2021-04-26T18:59:08", "dateReserved": "2021-01-05T00:00:00", "dateUpdated": "2024-08-03T18:51:06.922Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-32628 (GCVE-0-2023-32628)
Vulnerability from cvelistv5
Published
2023-06-05 23:14
Modified
2025-01-08 14:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Summary
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Advantech | WebAccess/SCADA |
Version: 0 < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:25:36.755Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-32628", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T14:22:24.832377Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T14:22:34.205Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "WebAccess/SCADA", "vendor": "Advantech", "versions": [ { "lessThanOrEqual": "v9.1.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "YangLiu from Elex Feigong Research Institute reported these vulnerabilities to CISA." } ], "datePublic": "2023-06-01T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n" } ], "value": "\n\n\n\n\nIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.\n\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-05T23:14:00.388Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAdvantech recommends WebAccess/SCADA users upgrade to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ev9.1.4\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. \u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nAdvantech recommends WebAccess/SCADA users upgrade to v9.1.4 https://www.advantech.com/en/support/details/installation . \n\n\n" } ], "source": { "advisory": "ICSA-23-152-01", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-32628", "datePublished": "2023-06-05T23:14:00.388Z", "dateReserved": "2023-05-22T18:07:54.479Z", "dateUpdated": "2025-01-08T14:22:34.205Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-13551 (GCVE-0-2020-13551)
Vulnerability from cvelistv5
Published
2021-02-17 18:17
Modified
2024-08-04 12:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:25:15.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-17T18:17:14", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2020-13551", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via PostgreSQL executable, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276: Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2020-13551", "datePublished": "2021-02-17T18:17:14", "dateReserved": "2020-05-26T00:00:00", "dateUpdated": "2024-08-04T12:25:15.218Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-13555 (GCVE-0-2020-13555)
Vulnerability from cvelistv5
Published
2021-02-17 18:23
Modified
2024-08-04 12:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:25:15.254Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-17T18:23:29", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2020-13555", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In COM Server Application Privilege Escalation, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276: Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2020-13555", "datePublished": "2021-02-17T18:23:29", "dateReserved": "2020-05-26T00:00:00", "dateUpdated": "2024-08-04T12:25:15.254Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-32943 (GCVE-0-2021-32943)
Vulnerability from cvelistv5
Published
2021-08-10 14:03
Modified
2024-08-03 23:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW
Summary
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | WebAccess/SCADA |
Version: WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:33:55.931Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "STACK-BASED BUFFER OVERFLOW CWE-121", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T14:03:48", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32943", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "STACK-BASED BUFFER OVERFLOW CWE-121" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-32943", "datePublished": "2021-08-10T14:03:48", "dateReserved": "2021-05-13T00:00:00", "dateUpdated": "2024-08-03T23:33:55.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-5445 (GCVE-0-2018-5445)
Vulnerability from cvelistv5
Published
2018-01-25 03:00
Modified
2024-08-05 05:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: Advantech WebAccess/SCADA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:33:44.377Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "name": "102781", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/102781" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA" } ] } ], "datePublic": "2018-01-24T00:00:00", "descriptions": [ { "lang": "en", "value": "A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-01-25T10:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "name": "102781", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/102781" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-5445", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "name": "102781", "refsource": "BID", "url": "http://www.securityfocus.com/bid/102781" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-5445", "datePublished": "2018-01-25T03:00:00", "dateReserved": "2018-01-12T00:00:00", "dateUpdated": "2024-08-05T05:33:44.377Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22676 (GCVE-0-2021-22676)
Vulnerability from cvelistv5
Published
2021-08-10 14:02
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING')
Summary
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | WebAccess/SCADA |
Version: WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.046Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T14:02:10", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-22676", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-22676", "datePublished": "2021-08-10T14:02:10", "dateReserved": "2021-01-05T00:00:00", "dateUpdated": "2024-08-03T18:51:07.046Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6523 (GCVE-0-2019-6523)
Vulnerability from cvelistv5
Published
2019-02-05 21:00
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:21.412Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106722" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2019-02-05T00:00:00", "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106722" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-6523", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106722" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-6523", "datePublished": "2019-02-05T21:00:00", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:21.412Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-13552 (GCVE-0-2020-13552)
Vulnerability from cvelistv5
Published
2021-02-17 18:16
Modified
2024-08-04 12:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:25:15.252Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-17T18:16:44", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2020-13552", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In privilege escalation via multiple service executables in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276: Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2020-13552", "datePublished": "2021-02-17T18:16:44", "dateReserved": "2020-05-26T00:00:00", "dateUpdated": "2024-08-04T12:25:15.252Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-1437 (GCVE-0-2023-1437)
Vulnerability from cvelistv5
Published
2023-08-02 22:30
Modified
2024-08-02 05:49
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-822 - Untrusted Pointer Dereference
Summary
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Advantech | WebAccess/SCADA |
Version: 0 < 9.1.4 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:49:11.643Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "WebAccess/SCADA", "vendor": "Advantech", "versions": [ { "lessThan": "9.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Florent Saudel" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eAll versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.\u003c/p\u003e" } ], "value": "All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-822", "description": "CWE-822 Untrusted Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-11T14:34:24.399Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02" } ], "source": { "discovery": "UNKNOWN" }, "title": "CVE-2023-1437", "x_generator": { "engine": "VINCE 2.1.3", "env": "prod", "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-1437" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-1437", "datePublished": "2023-08-02T22:30:43.978Z", "dateReserved": "2023-03-16T22:01:32.632Z", "dateUpdated": "2024-08-02T05:49:11.643Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22674 (GCVE-0-2021-22674)
Vulnerability from cvelistv5
Published
2021-08-10 14:00
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-23 - RELATIVE PATH TRAVERSAL
Summary
The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | WebAccess/SCADA |
Version: WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:06.022Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-23", "description": "RELATIVE PATH TRAVERSAL CWE-23", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T14:00:51", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-22674", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The affected product is vulnerable to a relative path traversal condition, which may allow an attacker access to unauthorized files and directories on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "RELATIVE PATH TRAVERSAL CWE-23" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-217-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-22674", "datePublished": "2021-08-10T14:00:51", "dateReserved": "2021-01-05T00:00:00", "dateUpdated": "2024-08-03T18:51:06.022Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-27436 (GCVE-0-2021-27436)
Vulnerability from cvelistv5
Published
2021-03-18 21:24
Modified
2024-08-03 20:48
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING')
Summary
WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: Versions 9.0 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.186Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Versions 9.0 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user\u2019s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-18T21:24:57", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27436", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "Versions 9.0 and prior" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user\u2019s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-075-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27436", "datePublished": "2021-03-18T21:24:57", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.186Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-32954 (GCVE-0-2021-32954)
Vulnerability from cvelistv5
Published
2021-06-18 13:53
Modified
2024-08-03 23:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-23 - RELATIVE PATH TRAVERSAL
Summary
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: WebAccess/SCADA Versions 9.0.1 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:33:55.935Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA Versions 9.0.1 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-23", "description": "RELATIVE PATH TRAVERSAL CWE-23", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-18T13:53:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32954", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA Versions 9.0.1 and prior" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "RELATIVE PATH TRAVERSAL CWE-23" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-32954", "datePublished": "2021-06-18T13:53:01", "dateReserved": "2021-05-13T00:00:00", "dateUpdated": "2024-08-03T23:33:55.935Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-32956 (GCVE-0-2021-32956)
Vulnerability from cvelistv5
Published
2021-06-18 13:52
Modified
2024-08-03 23:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-601 - URL REDIRECTION TO UNTRUSTED SITE ('OPEN REDIRECT')
Summary
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: WebAccess/SCADA Versions 9.0.1 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:33:55.949Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA Versions 9.0.1 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-601", "description": "URL REDIRECTION TO UNTRUSTED SITE (\u0027OPEN REDIRECT\u0027) CWE-601", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-18T13:52:51", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32956", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA Versions 9.0.1 and prior" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "URL REDIRECTION TO UNTRUSTED SITE (\u0027OPEN REDIRECT\u0027) CWE-601" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-168-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-32956", "datePublished": "2021-06-18T13:52:51", "dateReserved": "2021-05-13T00:00:00", "dateUpdated": "2024-08-03T23:33:55.949Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-13550 (GCVE-0-2020-13550)
Vulnerability from cvelistv5
Published
2021-02-17 18:10
Modified
2024-08-04 12:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:25:15.202Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-17T18:10:58", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2020-13550", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A local file inclusion vulnerability exists in the installation functionality of Advantech WebAccess/SCADA 9.0.1. A specially crafted application can lead to information disclosure. An attacker can send an authenticated HTTP request to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 7.7, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1168" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2020-13550", "datePublished": "2021-02-17T18:10:58", "dateReserved": "2020-05-26T00:00:00", "dateUpdated": "2024-08-04T12:25:15.202Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-22450 (GCVE-0-2023-22450)
Vulnerability from cvelistv5
Published
2023-06-05 23:17
Modified
2025-01-08 14:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Summary
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Advantech | WebAccess/SCADA |
Version: 0 < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:13:48.320Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-22450", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T14:21:03.532091Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T14:21:41.605Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "WebAccess/SCADA", "vendor": "Advantech", "versions": [ { "lessThanOrEqual": "v9.1.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "YangLiu from Elex Feigong Research Institute reported these vulnerabilities to CISA." } ], "datePublic": "2023-06-01T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.\u003c/span\u003e\n\n\u003c/span\u003e\n\n" } ], "value": "\n\n\nIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-05T23:17:47.003Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAdvantech recommends WebAccess/SCADA users upgrade to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ev9.1.4\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. \u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nAdvantech recommends WebAccess/SCADA users upgrade to v9.1.4 https://www.advantech.com/en/support/details/installation . \n\n\n" } ], "source": { "advisory": "ICSA-23-152-01", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-22450", "datePublished": "2023-06-05T23:17:47.003Z", "dateReserved": "2023-05-22T18:07:54.484Z", "dateUpdated": "2025-01-08T14:21:41.605Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18999 (GCVE-0-2018-18999)
Vulnerability from cvelistv5
Published
2018-12-19 18:00
Modified
2024-08-05 11:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - IMPROPER INPUT VALIDATION
Summary
WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | WebAccess/SCADA |
Version: WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:23:08.967Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "name": "106245", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106245" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1" } ] } ], "datePublic": "2018-12-19T00:00:00", "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "IMPROPER INPUT VALIDATION CWE-20", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-20T10:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "name": "106245", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106245" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-18999", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER INPUT VALIDATION CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2018-45", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "name": "106245", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106245" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-18999", "datePublished": "2018-12-19T18:00:00", "dateReserved": "2018-11-06T00:00:00", "dateUpdated": "2024-08-05T11:23:08.967Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-13554 (GCVE-0-2020-13554)
Vulnerability from cvelistv5
Published
2021-03-03 16:14
Modified
2024-08-04 12:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:25:15.205Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-03T16:14:07", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2020-13554", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276: Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2020-13554", "datePublished": "2021-03-03T16:14:07", "dateReserved": "2020-05-26T00:00:00", "dateUpdated": "2024-08-04T12:25:15.205Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-32540 (GCVE-0-2023-32540)
Vulnerability from cvelistv5
Published
2023-06-05 23:16
Modified
2025-01-08 14:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Advantech | WebAccess/SCADA |
Version: 0 < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:18:37.624Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-32540", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T14:22:05.299928Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-08T14:22:14.896Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "WebAccess/SCADA", "vendor": "Advantech", "versions": [ { "lessThanOrEqual": "v9.1.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "YangLiu from Elex Feigong Research Institute reported these vulnerabilities to CISA." } ], "datePublic": "2023-06-01T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.\u003c/span\u003e\n\n" } ], "value": "\nIn Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-05T23:16:28.045Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAdvantech recommends WebAccess/SCADA users upgrade to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ev9.1.4\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. \u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nAdvantech recommends WebAccess/SCADA users upgrade to v9.1.4 https://www.advantech.com/en/support/details/installation . \n\n\n" } ], "source": { "advisory": "ICSA-23-152-01", "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-32540", "datePublished": "2023-06-05T23:16:28.045Z", "dateReserved": "2023-05-22T18:07:54.491Z", "dateUpdated": "2025-01-08T14:22:14.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6519 (GCVE-0-2019-6519)
Vulnerability from cvelistv5
Published
2019-02-05 21:00
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:21.516Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106722" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2019-02-05T00:00:00", "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106722" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-6519", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106722" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-6519", "datePublished": "2019-02-05T21:00:00", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:21.516Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6521 (GCVE-0-2019-6521)
Vulnerability from cvelistv5
Published
2019-02-05 21:00
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:21.489Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106722" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2019-02-05T00:00:00", "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106722" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-6521", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-024-01" }, { "name": "106722", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106722" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-6521", "datePublished": "2019-02-05T21:00:00", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:21.489Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-13553 (GCVE-0-2020-13553)
Vulnerability from cvelistv5
Published
2021-02-17 18:20
Modified
2024-08-04 12:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:25:15.222Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA 9.0.1" } ] } ], "descriptions": [ { "lang": "en", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-17T18:21:58", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2020-13553", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA 9.0.1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable local privilege elevation vulnerability exists in the file system permissions of Advantech WebAccess/SCADA 9.0.1 installation. In webvrpcs Run Key Privilege Escalation in installation folder of WebAccess, an attacker can either replace binary or loaded modules to execute code with NT SYSTEM privilege." } ] }, "impact": { "cvss": { "baseScore": 8.8, "baseSeverity": "High", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-276: Incorrect Default Permissions" } ] } ] }, "references": { "reference_data": [ { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1169" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2020-13553", "datePublished": "2021-02-17T18:20:47", "dateReserved": "2020-05-26T00:00:00", "dateUpdated": "2024-08-04T12:25:15.222Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-25161 (GCVE-0-2020-25161)
Vulnerability from cvelistv5
Published
2021-02-23 16:14
Modified
2024-08-04 15:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-73 - EXTERNAL CONTROL OF FILE NAME OR PATH
Summary
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: Versions 9.0 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:26:09.779Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Versions 9.0 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-73", "description": "EXTERNAL CONTROL OF FILE NAME OR PATH CWE-73", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-23T16:14:20", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-25161", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "Versions 9.0 and prior" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "EXTERNAL CONTROL OF FILE NAME OR PATH CWE-73" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-289-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-25161", "datePublished": "2021-02-23T16:14:20", "dateReserved": "2020-09-04T00:00:00", "dateUpdated": "2024-08-04T15:26:09.779Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-5443 (GCVE-0-2018-5443)
Vulnerability from cvelistv5
Published
2018-01-25 03:00
Modified
2024-08-05 05:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Advantech WebAccess/SCADA |
Version: Advantech WebAccess/SCADA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:33:44.434Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "name": "102781", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/102781" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Advantech WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Advantech WebAccess/SCADA" } ] } ], "datePublic": "2018-01-24T00:00:00", "descriptions": [ { "lang": "en", "value": "A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-01-25T10:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "name": "102781", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/102781" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-5443", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Advantech WebAccess/SCADA", "version": { "version_data": [ { "version_value": "Advantech WebAccess/SCADA" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-89" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-01" }, { "name": "102781", "refsource": "BID", "url": "http://www.securityfocus.com/bid/102781" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-5443", "datePublished": "2018-01-25T03:00:00", "dateReserved": "2018-01-12T00:00:00", "dateUpdated": "2024-08-05T05:33:44.434Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }