Vulnerabilites related to schneider-electric - wiser_smart_eer21000
CVE-2022-30233 (GCVE-0-2022-30233)
Vulnerability from cvelistv5
Published
2022-06-02 22:45
Modified
2024-09-17 03:29
CWE
  • CWE-20 - Improper Input Validation
Summary
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
Impacted products
Vendor Product Version
Schneider Electric Wiser Smart Version: EER21000   < 4.5
Version: EER21001   < 4.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:40:47.832Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wiser Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21000",
              "versionType": "custom"
            },
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21001",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-02T22:45:18",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
          "ID": "CVE-2022-30233",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wiser Smart",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21000",
                            "version_value": "4.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21001",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-30233",
    "datePublished": "2022-06-02T22:45:18.223723Z",
    "dateReserved": "2022-05-04T00:00:00",
    "dateUpdated": "2024-09-17T03:29:05.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-30236 (GCVE-0-2022-30236)
Vulnerability from cvelistv5
Published
2022-06-02 22:45
Modified
2024-09-16 23:00
CWE
  • CWE-669 - Incorrect Resource Transfer Between Spheres
Summary
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
Impacted products
Vendor Product Version
Schneider Electric Wiser Smart Version: EER21000   < 4.5
Version: EER21001   < 4.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:40:47.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wiser Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21000",
              "versionType": "custom"
            },
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21001",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-669",
              "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-02T22:45:22",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
          "ID": "CVE-2022-30236",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wiser Smart",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21000",
                            "version_value": "4.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21001",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-669 Incorrect Resource Transfer Between Spheres"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-30236",
    "datePublished": "2022-06-02T22:45:22.767960Z",
    "dateReserved": "2022-05-04T00:00:00",
    "dateUpdated": "2024-09-16T23:00:39.820Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-30238 (GCVE-0-2022-30238)
Vulnerability from cvelistv5
Published
2022-06-02 22:45
Modified
2024-09-17 03:29
CWE
  • CWE-287 - Improper Authentication
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
Impacted products
Vendor Product Version
Schneider Electric Wiser Smart Version: EER21000   < 4.5
Version: EER21001   < 4.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:40:47.892Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wiser Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21000",
              "versionType": "custom"
            },
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21001",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-02T22:45:25",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
          "ID": "CVE-2022-30238",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wiser Smart",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21000",
                            "version_value": "4.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21001",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287 Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-30238",
    "datePublished": "2022-06-02T22:45:25.728616Z",
    "dateReserved": "2022-05-04T00:00:00",
    "dateUpdated": "2024-09-17T03:29:08.122Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-30234 (GCVE-0-2022-30234)
Vulnerability from cvelistv5
Published
2022-06-02 22:45
Modified
2024-09-16 19:04
Severity ?
CWE
  • CWE-798 - Use of Hard-coded Credentials
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
Impacted products
Vendor Product Version
Schneider Electric Wiser Smart Version: EER21000   < 4.5
Version: EER21001   < 4.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:40:47.793Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wiser Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21000",
              "versionType": "custom"
            },
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21001",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-02T22:45:19",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
          "ID": "CVE-2022-30234",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wiser Smart",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21000",
                            "version_value": "4.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21001",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-30234",
    "datePublished": "2022-06-02T22:45:19.768519Z",
    "dateReserved": "2022-05-04T00:00:00",
    "dateUpdated": "2024-09-16T19:04:21.194Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-30235 (GCVE-0-2022-30235)
Vulnerability from cvelistv5
Published
2022-06-02 22:45
Modified
2024-09-16 17:59
CWE
  • CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
Impacted products
Vendor Product Version
Schneider Electric Wiser Smart Version: EER21000   < 4.5
Version: EER21001   < 4.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:40:47.777Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wiser Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21000",
              "versionType": "custom"
            },
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21001",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-02T22:45:21",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
          "ID": "CVE-2022-30235",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wiser Smart",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21000",
                            "version_value": "4.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21001",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-307 Improper Restriction of Excessive Authentication Attempts"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-30235",
    "datePublished": "2022-06-02T22:45:21.168189Z",
    "dateReserved": "2022-05-04T00:00:00",
    "dateUpdated": "2024-09-16T17:59:43.987Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-30237 (GCVE-0-2022-30237)
Vulnerability from cvelistv5
Published
2022-06-02 22:45
Modified
2024-09-17 01:57
CWE
  • CWE-311 - Missing Encryption of Sensitive Data
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
References
Impacted products
Vendor Product Version
Schneider Electric Wiser Smart Version: EER21000   < 4.5
Version: EER21001   < 4.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:40:47.884Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wiser Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21000",
              "versionType": "custom"
            },
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "EER21001",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-311",
              "description": "CWE-311 Missing Encryption of Sensitive Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-02T22:45:24",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-05-10T07:00:00.000Z",
          "ID": "CVE-2022-30237",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wiser Smart",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21000",
                            "version_value": "4.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "EER21001",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-311 Missing Encryption of Sensitive Data"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-30237",
    "datePublished": "2022-06-02T22:45:24.206860Z",
    "dateReserved": "2022-05-04T00:00:00",
    "dateUpdated": "2024-09-17T01:57:03.909Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2022-06-02 23:15
Modified
2024-11-21 07:02
Summary
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
    },
    {
      "lang": "es",
      "value": "Una CWE-311: Se presenta una vulnerabilidad de Falta de Encriptaci\u00f3n de Datos Confidenciales que podr\u00eda permitir recuperar las credenciales de autenticaci\u00f3n cuando un atacante rompe la codificaci\u00f3n. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
    }
  ],
  "id": "CVE-2022-30237",
  "lastModified": "2024-11-21T07:02:25.763",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-02T23:15:07.730",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-311"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-02 23:15
Modified
2024-11-21 07:02
Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
    },
    {
      "lang": "es",
      "value": "Una CWE-307: Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de intentos de Autenticaci\u00f3n Excesivos que podr\u00eda permitir el acceso no autorizado cuando un atacante usa fuerza bruta. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
    }
  ],
  "id": "CVE-2022-30235",
  "lastModified": "2024-11-21T07:02:25.523",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-02T23:15:07.617",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-307"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-02 23:15
Modified
2024-11-21 07:02
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
    },
    {
      "lang": "es",
      "value": "UNA CWE-287: Se presenta una vulnerabilidad de Autenticaci\u00f3n Inapropiada que podr\u00eda permitir a un atacante tomar el control de la cuenta de administrador cuando un atacante secuestra una sesi\u00f3n. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
    }
  ],
  "id": "CVE-2022-30238",
  "lastModified": "2024-11-21T07:02:25.880",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.5,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-02T23:15:07.787",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-02 23:15
Modified
2024-11-21 07:02
Summary
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
    },
    {
      "lang": "es",
      "value": "Una CWE-669: Se presenta una vulnerabilidad de Transferencia Incorrecta de Recursos Entre Esferas que podr\u00eda permitir el acceso no autorizado cuando un atacante usa ataques entre dominios. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
    }
  ],
  "id": "CVE-2022-30236",
  "lastModified": "2024-11-21T07:02:25.647",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 6.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-02T23:15:07.673",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-669"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-02 23:15
Modified
2024-11-21 07:02
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
    },
    {
      "lang": "es",
      "value": "Una CWE-798: Se presenta una vulnerabilidad en el Uso de Credenciales Embebidas que podr\u00eda permitir la ejecuci\u00f3n de c\u00f3digo arbitrario cuando es obtenido acceso a nivel root. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
    }
  ],
  "id": "CVE-2022-30234",
  "lastModified": "2024-11-21T07:02:25.400",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 9.4,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.5,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-02T23:15:07.560",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-06-02 23:15
Modified
2024-11-21 07:02
Summary
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FF54835-9F49-417D-985F-24799D9B93A0",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5552670-EDA0-4C30-B292-2228FB418A38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_smart_eer21001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E7CC55-F222-470E-AA71-DEECB4A971F6",
              "versionEndIncluding": "4.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_smart_eer21001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D3AC8F-AA3E-4173-89FB-6F8EA59FA52B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)"
    },
    {
      "lang": "es",
      "value": "Una CWE-20: Se presenta una vulnerabilidad de Comprobaci\u00f3n de Entrada Inapropiada que podr\u00eda permitir una manipulaci\u00f3n maliciosa del producto cuando es enga\u00f1ado al usuario para que lleve a cabo determinadas acciones en una p\u00e1gina web. Productos afectados: Wiser Smart, EER21000 y EER21001 (versiones V4.5 y anteriores)"
    }
  ],
  "id": "CVE-2022-30233",
  "lastModified": "2024-11-21T07:02:25.277",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-06-02T23:15:07.507",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2022-130-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Primary"
    }
  ]
}