CVE-2017-14443 (GCVE-0-2017-14443)
Vulnerability from cvelistv5
Published
2018-09-17 17:00
Modified
2024-08-05 19:27
Severity ?
CWE
  • n/a
Summary
An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:27:40.515Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-06-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T18:20:49",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2017-14443",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.6,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492",
              "refsource": "MISC",
              "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2017-14443",
    "datePublished": "2018-09-17T17:00:00",
    "dateReserved": "2017-09-13T00:00:00",
    "dateUpdated": "2024-08-05T19:27:40.515Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-14443\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2018-09-17T17:29:00.267\",\"lastModified\":\"2024-11-21T03:12:48.360\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad explotable de fuga de informaci\u00f3n en Insteon Hub, con la versi\u00f3n 1012 de firmware. La implementaci\u00f3n del servidor HTTP comprueba de forma incorrecta el n\u00famero de par\u00e1metros GET proporcionados, lo que conduce a una fuga de informaci\u00f3n controlada de forma arbitraria en toda la memoria del dispositivo. Un atacante puede enviar una petici\u00f3n HTTP autenticada para provocar esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:H\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.1,\"impactScore\":5.8}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:insteon:hub_2245-222_firmware:1012:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2532FA22-D435-47E6-8DFA-47377B1959D6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:insteon:hub_2245-222:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"150E9049-5523-4BC3-A5A5-473B6D320B68\"}]}]}],\"references\":[{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.