gsd-2017-14443
Vulnerability from gsd
Modified
2023-12-13 01:21
Details
An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2017-14443", "description": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability.", "id": "GSD-2017-14443" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2017-14443" ], "details": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability.", "id": "GSD-2017-14443", "modified": "2023-12-13T01:21:12.914827Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2017-14443", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 9.6, "baseSeverity": "Critical", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492", "refsource": "MISC", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:insteon:hub_2245-222_firmware:1012:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:insteon:hub_2245-222:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2017-14443" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-200" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492", "refsource": "MISC", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0492" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } }, "lastModifiedDate": "2022-12-14T16:13Z", "publishedDate": "2018-09-17T17:29Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…