CVE-2021-44464 (GCVE-0-2021-44464)
Vulnerability from cvelistv5
Published
2022-01-21 18:17
Modified
2025-04-16 16:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Summary
Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Fresenius Kabi | Vigilant Software Suite (Mastermed Dashboard) |
Version: unspecified < 2.0.1.3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:25:16.824Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2021-44464", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-16T15:56:40.775925Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-16T16:47:01.630Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Vigilant Software Suite (Mastermed Dashboard)", "vendor": "Fresenius Kabi", "versions": [ { "lessThan": "2.0.1.3", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project)." } ], "descriptions": [ { "lang": "en", "value": "Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-21T18:17:42.000Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01" } ], "solutions": [ { "lang": "en", "value": "Fresenius Kabi has created new versions to address these vulnerabilities:\n\u2022\tLink+ v3.0 (D16 or later)\n\u2022\tVSS v1.0.3 (or later)\n\u2022\tAgilia Connect Pumps Wifi Module (D29 or later)\n\u2022\tAgilia Connect Partner v3.3.2 (or later) \nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \n" } ], "source": { "advisory": "ICSMA-21-355-01", "discovery": "EXTERNAL" }, "title": "Fresenius Kabi Agilia Connect Infusion System hard coded credentials", "workarounds": [ { "lang": "en", "value": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\u2022\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\n\u2022\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\n\u2022\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n" } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-44464", "STATE": "PUBLIC", "TITLE": "Fresenius Kabi Agilia Connect Infusion System hard coded credentials" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Vigilant Software Suite (Mastermed Dashboard)", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "2.0.1.3" } ] } } ] }, "vendor_name": "Fresenius Kabi" } ] } }, "credit": [ { "lang": "eng", "value": "Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project)." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798 Use of Hard-coded Credentials" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01" } ] }, "solution": [ { "lang": "en", "value": "Fresenius Kabi has created new versions to address these vulnerabilities:\n\u2022\tLink+ v3.0 (D16 or later)\n\u2022\tVSS v1.0.3 (or later)\n\u2022\tAgilia Connect Pumps Wifi Module (D29 or later)\n\u2022\tAgilia Connect Partner v3.3.2 (or later) \nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \n" } ], "source": { "advisory": "ICSMA-21-355-01", "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\u2022\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\n\u2022\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\n\u2022\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n" } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-44464", "datePublished": "2022-01-21T18:17:42.000Z", "dateReserved": "2021-11-30T00:00:00.000Z", "dateUpdated": "2025-04-16T16:47:01.630Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-44464\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-01-21T19:15:09.403\",\"lastModified\":\"2024-11-21T06:31:01.760\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software.\"},{\"lang\":\"es\",\"value\":\"Vigilant Software Suite (Mastermed Dashboard) versi\u00f3n 2.0.1.3, contiene credenciales de servicio que probablemente sean comunes en todas las instancias. Un atacante en posesi\u00f3n de la contrase\u00f1a puede alcanzar privilegios en todas las instalaciones de este software\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:agilia_connect_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"d25\",\"matchCriteriaId\":\"8B4979F9-A7D5-4B5C-8FF2-C3C67773EE03\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fresenius-kabi:agilia_connect:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D1BBB63E-7E43-4BC1-A08F-4F1F811F839B\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:agilia_partner_maintenance_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.3.0\",\"matchCriteriaId\":\"3B072164-6AA2-4A14-B7D7-10B4B953004D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:vigilant_centerium:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C47210A7-4753-4ED7-8E6B-9BE8EBFABC9F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:vigilant_insight:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C91B931-F726-4AB2-B3A6-D92F774CF04D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fresenius-kabi:vigilant_mastermed:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04AC7167-F5C8-46A2-B937-953E13D76A32\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:link\\\\+_agilia_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0\",\"matchCriteriaId\":\"45FA28DE-939F-4146-A6E2-CE8849C9CB16\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:link\\\\+_agilia_firmware:3.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D5FC3D0-9593-487B-B70A-F8BBCA8A18FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fresenius-kabi:link\\\\+_agilia_firmware:3.0:d15:*:*:*:*:*:*\",\"matchCriteriaId\":\"67E88F2E-C12B-4B50-B087-3247F4748AF3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fresenius-kabi:link\\\\+_agilia:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1548AA3F-659F-43C3-9261-C7FD55465877\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T04:25:16.824Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-44464\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T15:56:40.775925Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T15:56:43.163Z\"}}], \"cna\": {\"title\": \"Fresenius Kabi Agilia Connect Infusion System hard coded credentials\", \"source\": {\"advisory\": \"ICSMA-21-355-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project).\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Fresenius Kabi\", \"product\": \"Vigilant Software Suite (Mastermed Dashboard)\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"lessThan\": \"2.0.1.3\", \"versionType\": \"custom\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Fresenius Kabi has created new versions to address these vulnerabilities:\\n\\u2022\\tLink+ v3.0 (D16 or later)\\n\\u2022\\tVSS v1.0.3 (or later)\\n\\u2022\\tAgilia Connect Pumps Wifi Module (D29 or later)\\n\\u2022\\tAgilia Connect Partner v3.3.2 (or later) \\nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \\n\"}], \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"tags\": [\"x_refsource_MISC\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\\n\\u2022\\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\\n\\u2022\\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\\n\\u2022\\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\\n\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-798\", \"description\": \"CWE-798 Use of Hard-coded Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-01-21T18:17:42.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project).\"}], \"impact\": {\"cvss\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}, \"source\": {\"advisory\": \"ICSMA-21-355-01\", \"discovery\": \"EXTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"2.0.1.3\", \"version_affected\": \"\u003c\"}]}, \"product_name\": \"Vigilant Software Suite (Mastermed Dashboard)\"}]}, \"vendor_name\": \"Fresenius Kabi\"}]}}, \"solution\": [{\"lang\": \"en\", \"value\": \"Fresenius Kabi has created new versions to address these vulnerabilities:\\n\\u2022\\tLink+ v3.0 (D16 or later)\\n\\u2022\\tVSS v1.0.3 (or later)\\n\\u2022\\tAgilia Connect Pumps Wifi Module (D29 or later)\\n\\u2022\\tAgilia Connect Partner v3.3.2 (or later) \\nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \\n\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-798 Use of Hard-coded Credentials\"}]}]}, \"work_around\": [{\"lang\": \"en\", \"value\": \"CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\\n\\u2022\\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\\n\\u2022\\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\\n\\u2022\\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\\n\"}], \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-44464\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Fresenius Kabi Agilia Connect Infusion System hard coded credentials\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2021-44464\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T16:47:01.630Z\", \"dateReserved\": \"2021-11-30T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-01-21T18:17:42.000Z\", \"assignerShortName\": \"icscert\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…