CVE-2020-10919 (GCVE-0-2020-10919)
Vulnerability from cvelistv5
Published
2020-07-23 15:35
Modified
2024-08-04 11:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-261 - Weak Cryptography for Passwords
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:14:15.726Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "HMI EA9", "vendor": "C-MORE", "versions": [ { "status": "affected", "version": "Firmware version 6.52" } ] } ], "credits": [ { "lang": "en", "value": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)" } ], "descriptions": [ { "lang": "en", "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-261", "description": "CWE-261: Weak Cryptography for Passwords", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-26T21:30:13", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "zdi-disclosures@trendmicro.com", "ID": "CVE-2020-10919", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "HMI EA9", "version": { "version_data": [ { "version_value": "Firmware version 6.52" } ] } } ] }, "vendor_name": "C-MORE" } ] } }, "credit": "Ta-Lun Yen \u0026 Chizuru Toyama of TXOne IoT/ICS Security Research Labs (Trend Micro)", "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185." } ] }, "impact": { "cvss": { "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-261: Weak Cryptography for Passwords" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-806/" } ] } } } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2020-10919", "datePublished": "2020-07-23T15:35:18", "dateReserved": "2020-03-24T00:00:00", "dateUpdated": "2024-08-04T11:14:15.726Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-10919\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2020-07-23T16:15:12.193\",\"lastModified\":\"2024-11-21T04:56:22.183\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-10185.\"},{\"lang\":\"es\",\"value\":\"Esta vulnerabilidad permite a los atacantes remotos revelar informaci\u00f3n sensible en las instalaciones afectadas de los paneles de pantalla t\u00e1ctil C-MORE HMI EA9 Firmware versi\u00f3n 6.52. La autenticaci\u00f3n no es necesaria para explotar esta vulnerabilidad. El fallo espec\u00edfico existe en el manejo de las contrase\u00f1as. Al transmitir las contrase\u00f1as, el proceso las encripta en un formato recuperable. Un atacante puede aprovechar esta vulnerabilidad para revelar las credenciales, lo que llevar\u00eda a un mayor compromiso. Era ZDI-CAN-10185\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-261\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-326\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:automationdirect:c-more_hmi_ea9_firmware:6.52:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1C98599-C96A-4EEE-BC82-A6F01398E077\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-pgmsw:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"656B3283-FA47-4CCF-A124-FBAEC86BB7A7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-rhmi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DD7D15B5-FC1D-4B0E-85CC-CEF3A68C2BA4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t10cl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"584FBF19-4AFB-425F-9A78-A450C8EF4D74\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t10wcl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F79F5A11-21E8-4126-8333-1DEAFD91100E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t12cl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F3BC5B7-55B3-41FC-959F-745171FD6AB8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t15cl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63E6454D-E722-45DA-8AD7-4469DA515B62\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t15cl-r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B271A9F-5E71-4C03-8A78-84398183903C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t6cl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"43E2E05B-41C9-4BE6-9344-2A78C3CE0B11\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t6cl-r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF5C6D94-BFA6-48FF-9776-FA7C91ABE1CD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t7cl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABC8D7A3-A3CD-4C6F-8256-FD91927C1CE4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t7cl-r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BE509D4-C93C-4A7F-B5C9-892073640916\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:automationdirect:ea9-t8cl:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66885733-FD7F-4BAB-9F41-1823372FBA6D\"}]}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-20-806/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-20-806/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.