CVE-2020-29032 (GCVE-0-2020-29032)
Vulnerability from cvelistv5
Published
2021-03-05 16:58
Modified
2024-09-16 16:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-494 - Download of Code Without Integrity Check
Summary
Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022
References
► | URL | Tags | |
---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Secomea | GateManager |
Version: all < 9.4.621054022 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:48:01.434Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-06" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "GateManager", "vendor": "Secomea", "versions": [ { "lessThan": "9.4.621054022", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Tenable" } ], "datePublic": "2021-03-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-494", "description": "CWE-494 Download of Code Without Integrity Check", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-09T06:06:27", "orgId": "f2815942-3388-4c08-ba09-6c15850fda90", "shortName": "Secomea" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-06" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737" } ], "source": { "defect": [ "RD-3737" ], "discovery": "EXTERNAL" }, "title": "Add integrity check of GateManager firmware", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "VulnerabilityReporting@secomea.com", "DATE_PUBLIC": "2021-03-04T22:00:00.000Z", "ID": "CVE-2020-29032", "STATE": "PUBLIC", "TITLE": "Add integrity check of GateManager firmware" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "GateManager", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "all", "version_value": "9.4.621054022" } ] } } ] }, "vendor_name": "Secomea" } ] } }, "credit": [ { "lang": "eng", "value": "Tenable" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-494 Download of Code Without Integrity Check" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-06", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-06" }, { "name": "https://www.secomea.com/support/cybersecurity-advisory/#3737", "refsource": "MISC", "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737" } ] }, "source": { "defect": [ "RD-3737" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90", "assignerShortName": "Secomea", "cveId": "CVE-2020-29032", "datePublished": "2021-03-05T16:58:27.148457Z", "dateReserved": "2020-11-24T00:00:00", "dateUpdated": "2024-09-16T16:32:33.185Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-29032\",\"sourceIdentifier\":\"VulnerabilityReporting@secomea.com\",\"published\":\"2021-03-05T17:15:13.937\",\"lastModified\":\"2024-11-21T05:23:34.187\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Carga de C\u00f3digo Sin Comprobaci\u00f3n de integridad en el archivo de firmware de Secomea GateManager, permite a un atacante autenticado ejecutar c\u00f3digo malicioso en el servidor. Este problema afecta a: Secomea GateManager todas las versiones anteriores a 9.4.621054022\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.7,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-494\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.4.621054022\",\"matchCriteriaId\":\"FCB5D947-8F29-47C8-9FCB-DF38087C39BC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5089C475-2013-4DF6-AD1E-12F576ACAE8E\"}]}]}],\"references\":[{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3737\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-06\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3737\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…