CVE-2021-38440 (GCVE-0-2021-38440)
Vulnerability from cvelistv5
Published
2021-10-18 12:38
Modified
2024-09-17 04:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-125 - OUT-OF-BOUNDS READ
Summary
FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
FATEK Automation | WinProladder |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:44:22.329Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WinProladder", "vendor": "FATEK Automation", "versions": [ { "lessThanOrEqual": "3.30", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "xina1i and Natnael Samson (@NattiSamson), working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA." } ], "datePublic": "2021-10-07T00:00:00", "descriptions": [ { "lang": "en", "value": "FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "OUT-OF-BOUNDS READ CWE-125", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-18T12:38:47", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-06" } ], "source": { "advisory": "ICSA-21-280-06", "discovery": "UNKNOWN" }, "title": "FATEK Automation WinProladder", "workarounds": [ { "lang": "en", "value": "FATEK Automation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of these affected products are invited to contact FATEK customer support for additional information." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-10-07T18:22:00.000Z", "ID": "CVE-2021-38440", "STATE": "PUBLIC", "TITLE": "FATEK Automation WinProladder" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WinProladder", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.30" } ] } } ] }, "vendor_name": "FATEK Automation" } ] } }, "credit": [ { "lang": "eng", "value": "xina1i and Natnael Samson (@NattiSamson), working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OUT-OF-BOUNDS READ CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-06", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-280-06" } ] }, "source": { "advisory": "ICSA-21-280-06", "discovery": "UNKNOWN" }, "work_around": [ { "lang": "en", "value": "FATEK Automation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of these affected products are invited to contact FATEK customer support for additional information." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-38440", "datePublished": "2021-10-18T12:38:47.229996Z", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-09-17T04:09:30.941Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-38440\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2021-10-18T13:15:09.880\",\"lastModified\":\"2024-11-21T06:17:06.330\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"FATEK Automation WinProladder versions 3.30 and prior is vulnerable to an out-of-bounds read, which may allow an attacker to read unauthorized information.\"},{\"lang\":\"es\",\"value\":\"FATEK Automation WinProladder versiones 3.30 y anteriores, es vulnerable a una lectura fuera de l\u00edmites, que podr\u00eda permitir a un atacante leer informaci\u00f3n no autorizada\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fatek:winproladder:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.30\",\"matchCriteriaId\":\"B20C2F2A-8F6A-4642-B921-99948FE5E0FB\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-06\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-280-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…