CVE-2022-46670 (GCVE-0-2022-46670)
Vulnerability from cvelistv5
Published
2022-12-16 20:12
Modified
2025-04-17 14:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.
References
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Rockwell Automation | MicroLogix 1100 & 1400 Controllers |
Version: All |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:39:38.680Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-46670", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-17T14:35:20.399901Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-17T14:35:29.173Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "MicroLogix 1100 \u0026 1400 Controllers", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "All" } ] }, { "defaultStatus": "unaffected", "product": "MicroLogix 1400-B/C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "21.007 and below" } ] }, { "defaultStatus": "unaffected", "product": "MicroLogix 1400-A", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "7.000 and below" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Ryan Pickren, a security researcher from Georgia Institute of Technology" } ], "datePublic": "2022-12-13T15:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u0026nbsp;of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u0026nbsp;The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \u003c/span\u003e\n\n" } ], "value": "\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \n\n" } ], "impacts": [ { "capecId": "CAPEC-63", "descriptions": [ { "lang": "en", "value": "CAPEC-63 Cross-Site Scripting (XSS)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-16T20:12:22.414Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679" } ], "source": { "discovery": "UNKNOWN" }, "title": "Rockwell Automation MicroLogix 1100 \u0026 1400 Vulnerable to Cross-Site Scripting Attack", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2022-46670", "datePublished": "2022-12-16T20:12:22.414Z", "dateReserved": "2022-12-06T15:27:58.542Z", "dateUpdated": "2025-04-17T14:35:29.173Z", "requesterUserId": "20b06643-9bf3-4d1d-a98d-f8db99f95a31", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-46670\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2022-12-16T21:15:09.040\",\"lastModified\":\"2024-11-21T07:30:52.580\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \\n\\n\"},{\"lang\":\"es\",\"value\":\"Un investigador de seguridad del Instituto de Tecnolog\u00eda de Georgia inform\u00f3 a Rockwell Automation de una vulnerabilidad que indica que los controladores MicroLogix 1100 y 1400 contienen una vulnerabilidad que puede brindarle a un atacante la capacidad de realizar la ejecuci\u00f3n remota de c\u00f3digo. La vulnerabilidad es de Cross-Site Scripting almacenado, no autenticada en el servidor web integrado. El payload se transfiere al controlador a trav\u00e9s de SNMP y se representa en la p\u00e1gina de inicio del sitio web integrado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11507EFF-5C53-4217-9257-21936118C032\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"196EA0BE-FDF3-46BE-B3DA-5F49208C5D80\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCE86CDF-12CC-4B02-942D-BF9134218F2B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA42C7F4-EEC1-44D2-BD46-237969FF6E1A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:micrologix_1400-b_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.007\",\"matchCriteriaId\":\"E6C4D215-CB09-4BEA-89A6-2BAACD461FBE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:micrologix_1400-b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D01BD0A-CA96-4882-8523-EC4D522DA4AF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:micrologix_1400-c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.007\",\"matchCriteriaId\":\"FD745E1D-10D9-4FD6-9F7C-63CB51F3C454\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:micrologix_1400-c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC9A2DE5-E745-4F1B-931C-E11814A7D23A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:micrologix_1400-a_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.000\",\"matchCriteriaId\":\"2E2B3E77-CF64-4D7F-A849-5462CABB576D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:micrologix_1400-a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"81AFED05-B927-4BF7-ABC5-5E3F7555593D\"}]}]}],\"references\":[{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:39:38.680Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-46670\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-17T14:35:20.399901Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-17T14:35:25.609Z\"}}], \"cna\": {\"title\": \"Rockwell Automation MicroLogix 1100 \u0026 1400 Vulnerable to Cross-Site Scripting Attack\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Ryan Pickren, a security researcher from Georgia Institute of Technology\"}], \"impacts\": [{\"capecId\": \"CAPEC-63\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-63 Cross-Site Scripting (XSS)\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 7.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"MicroLogix 1100 \u0026 1400 Controllers\", \"versions\": [{\"status\": \"affected\", \"version\": \"All\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"MicroLogix 1400-B/C\", \"versions\": [{\"status\": \"affected\", \"version\": \"21.007 and below\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"MicroLogix 1400-A\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.000 and below\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2022-12-13T15:00:00.000Z\", \"references\": [{\"url\": \"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\\u00a0of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \\u00a0The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eRockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute\u0026nbsp;of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. \u0026nbsp;The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. \u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2022-12-16T20:12:22.414Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-46670\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-17T14:35:29.173Z\", \"dateReserved\": \"2022-12-06T15:27:58.542Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2022-12-16T20:12:22.414Z\", \"requesterUserId\": \"20b06643-9bf3-4d1d-a98d-f8db99f95a31\", \"assignerShortName\": \"Rockwell\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…