CVE-2023-25608 (GCVE-0-2023-25608)
Vulnerability from cvelistv5
Published
2023-09-13 12:28
Modified
2024-09-24 20:00
CWE
Summary
An incomplete filtering of one or more instances of special elements vulnerability [CWE-792] in the command line interpreter of FortiAP-W2 7.2.0 through 7.2.1, 7.0.3 through 7.0.5, 7.0.0 through 7.0.1, 6.4 all versions, 6.2 all versions, 6.0 all versions; FortiAP-C 5.4.0 through 5.4.4, 5.2 all versions; FortiAP 7.2.0 through 7.2.1, 7.0.0 through 7.0.5, 6.4 all versions, 6.0 all versions; FortiAP-U 7.0.0, 6.2.0 through 6.2.5, 6.0 all versions, 5.4 all versions may allow an authenticated attacker to read arbitrary files via specially crafted command arguments.
Impacted products
Vendor Product Version
Fortinet FortiAP-W2 Version: 7.2.0    7.2.1
Version: 7.0.3    7.0.5
Version: 7.0.0    7.0.1
Version: 6.4.0    6.4.9
Version: 6.2.0    6.2.6
Version: 6.0.0    6.0.6
Create a notification for this product.
   Fortinet FortiAP-C Version: 5.4.0    5.4.4
Version: 5.2.0    5.2.1
Create a notification for this product.
   Fortinet FortiAP Version: 7.2.0    7.2.1
Version: 7.0.0    7.0.5
Version: 6.4.3    6.4.9
Version: 6.0.0    6.0.6
Create a notification for this product.
   Fortinet FortiAP-U Version: 7.0.0
Version: 6.2.0    6.2.5
Version: 6.0.0    6.0.4
Version: 5.4.3    5.4.6
Version: 5.4.0
Create a notification for this product.
   Fortinet FortiAP-S Version: 6.4.0    6.4.9
Version: 6.2.0    6.2.6
Version: 6.0.0    6.0.6
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:25:19.383Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-22-120",
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-22-120"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-25608",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-24T19:45:36.151614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-24T20:00:10.726Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiAP-W2",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.2.1",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.5",
              "status": "affected",
              "version": "7.0.3",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.1",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.4.9",
              "status": "affected",
              "version": "6.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.2.6",
              "status": "affected",
              "version": "6.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.0.6",
              "status": "affected",
              "version": "6.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FortiAP-C",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "5.4.4",
              "status": "affected",
              "version": "5.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "5.2.1",
              "status": "affected",
              "version": "5.2.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FortiAP",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.2.1",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.5",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.4.9",
              "status": "affected",
              "version": "6.4.3",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.0.6",
              "status": "affected",
              "version": "6.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FortiAP-U",
          "vendor": "Fortinet",
          "versions": [
            {
              "status": "affected",
              "version": "7.0.0"
            },
            {
              "lessThanOrEqual": "6.2.5",
              "status": "affected",
              "version": "6.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.0.4",
              "status": "affected",
              "version": "6.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "5.4.6",
              "status": "affected",
              "version": "5.4.3",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FortiAP-S",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "6.4.9",
              "status": "affected",
              "version": "6.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.2.6",
              "status": "affected",
              "version": "6.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.0.6",
              "status": "affected",
              "version": "6.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An incomplete filtering of one or more instances of special elements vulnerability [CWE-792] in the command line interpreter of FortiAP-W2 7.2.0 through 7.2.1, 7.0.3 through 7.0.5, 7.0.0 through 7.0.1, 6.4 all versions, 6.2 all versions, 6.0 all versions; FortiAP-C 5.4.0 through 5.4.4, 5.2 all versions; FortiAP 7.2.0 through 7.2.1, 7.0.0 through 7.0.5, 6.4 all versions, 6.0 all versions; FortiAP-U 7.0.0, 6.2.0 through 6.2.5, 6.0 all versions, 5.4 all versions may allow an authenticated attacker to read arbitrary files via specially crafted command arguments."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-792",
              "description": "Information disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-13T12:28:51.497Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.com/psirt/FG-IR-22-120",
          "url": "https://fortiguard.com/psirt/FG-IR-22-120"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiAP-W2 version 7.2.2 or above Please upgrade to FortiAP-W2 version 7.0.6 or above Please upgrade to FortiAP-C version 5.4.5 or above Please upgrade to FortiAP version 7.2.2 or above Please upgrade to FortiAP version 7.0.6 or above Please upgrade to FortiAP-U version 7.0.1 or above Please upgrade to FortiAP-U version 6.2.6 or above "
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2023-25608",
    "datePublished": "2023-09-13T12:28:51.497Z",
    "dateReserved": "2023-02-08T13:42:03.367Z",
    "dateUpdated": "2024-09-24T20:00:10.726Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-25608\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2023-09-13T13:15:08.040\",\"lastModified\":\"2024-11-21T07:49:49.420\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An incomplete filtering of one or more instances of special elements vulnerability [CWE-792] in the command line interpreter of FortiAP-W2 7.2.0 through 7.2.1, 7.0.3 through 7.0.5, 7.0.0 through 7.0.1, 6.4 all versions, 6.2 all versions, 6.0 all versions; FortiAP-C 5.4.0 through 5.4.4, 5.2 all versions; FortiAP 7.2.0 through 7.2.1, 7.0.0 through 7.0.5, 6.4 all versions, 6.0 all versions; FortiAP-U 7.0.0, 6.2.0 through 6.2.5, 6.0 all versions, 5.4 all versions may allow an authenticated attacker to read arbitrary files via specially crafted command arguments.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de filtrado incompleto de una o m\u00e1s instancias de elementos especiales [CWE-792] en el int\u00e9rprete de l\u00ednea de comando de FortiAP-W2 7.2.0 a 7.2.1, 7.0.3 a 7.0.5, 7.0.0 a 7.0.1, 6.4 todas las versiones, 6.2 todas las versiones, 6.0 todas las versiones; FortiAP-C 5.4.0 a 5.4.4, 5.2 todas las versiones; FortiAP 7.2.0 a 7.2.1, 7.0.0 a 7.0.5, 6.4 todas las versiones, 6.0 todas las versiones; FortiAP-U 7.0.0, 6.2.0 a 6.2.5, 6.0 todas las versiones, 5.4 todas las versiones puede permitir que un atacante autenticado lea archivos arbitrarios mediante argumentos de comando especialmente manipulados.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-792\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.0.0\",\"versionEndExcluding\":\"7.0.6\",\"matchCriteriaId\":\"B5BE67AF-5DC9-4942-832F-03BEC88CD2B9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.2.0\",\"versionEndExcluding\":\"7.2.2\",\"matchCriteriaId\":\"41C213D0-356F-425E-A124-5B72A3AEE54D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap-c:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.2.0\",\"versionEndExcluding\":\"5.4.5\",\"matchCriteriaId\":\"6E770699-3997-4E61-A4AD-68D102FCA4B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap-u:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4.0\",\"versionEndExcluding\":\"6.2.6\",\"matchCriteriaId\":\"2D44BE0A-B671-454C-8B6A-56AA4BA70E60\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap-u:7.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"743763F2-D4DE-4E9D-B112-7CA27C61A423\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap-w2:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.0.0\",\"versionEndIncluding\":\"7.0.1\",\"matchCriteriaId\":\"87E0B46B-B76D-4D27-AD6F-E929E362B6E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap-w2:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.3\",\"versionEndExcluding\":\"7.0.6\",\"matchCriteriaId\":\"B602BCD9-47CF-443C-A759-0B8379777768\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiap-w2:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.2.0\",\"versionEndExcluding\":\"7.2.2\",\"matchCriteriaId\":\"B9D26699-16AD-4752-A088-72CF117C98D0\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-120\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-120\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://fortiguard.com/psirt/FG-IR-22-120\", \"name\": \"https://fortiguard.com/psirt/FG-IR-22-120\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T11:25:19.383Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-25608\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-24T19:45:36.151614Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-24T20:00:03.921Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.2, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Fortinet\", \"product\": \"FortiAP-W2\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.2.1\"}, {\"status\": \"affected\", \"version\": \"7.0.3\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.0.5\"}, {\"status\": \"affected\", \"version\": \"7.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.0.1\"}, {\"status\": \"affected\", \"version\": \"6.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.4.9\"}, {\"status\": \"affected\", \"version\": \"6.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.2.6\"}, {\"status\": \"affected\", \"version\": \"6.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.0.6\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Fortinet\", \"product\": \"FortiAP-C\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"5.4.4\"}, {\"status\": \"affected\", \"version\": \"5.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"5.2.1\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Fortinet\", \"product\": \"FortiAP\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.2.1\"}, {\"status\": \"affected\", \"version\": \"7.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.0.5\"}, {\"status\": \"affected\", \"version\": \"6.4.3\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.4.9\"}, {\"status\": \"affected\", \"version\": \"6.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.0.6\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Fortinet\", \"product\": \"FortiAP-U\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0.0\"}, {\"status\": \"affected\", \"version\": \"6.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.2.5\"}, {\"status\": \"affected\", \"version\": \"6.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.0.4\"}, {\"status\": \"affected\", \"version\": \"5.4.3\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"5.4.6\"}, {\"status\": \"affected\", \"version\": \"5.4.0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Fortinet\", \"product\": \"FortiAP-S\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.4.9\"}, {\"status\": \"affected\", \"version\": \"6.2.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.2.6\"}, {\"status\": \"affected\", \"version\": \"6.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"6.0.6\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Please upgrade to FortiAP-W2 version 7.2.2 or above Please upgrade to FortiAP-W2 version 7.0.6 or above Please upgrade to FortiAP-C version 5.4.5 or above Please upgrade to FortiAP version 7.2.2 or above Please upgrade to FortiAP version 7.0.6 or above Please upgrade to FortiAP-U version 7.0.1 or above Please upgrade to FortiAP-U version 6.2.6 or above \"}], \"references\": [{\"url\": \"https://fortiguard.com/psirt/FG-IR-22-120\", \"name\": \"https://fortiguard.com/psirt/FG-IR-22-120\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An incomplete filtering of one or more instances of special elements vulnerability [CWE-792] in the command line interpreter of FortiAP-W2 7.2.0 through 7.2.1, 7.0.3 through 7.0.5, 7.0.0 through 7.0.1, 6.4 all versions, 6.2 all versions, 6.0 all versions; FortiAP-C 5.4.0 through 5.4.4, 5.2 all versions; FortiAP 7.2.0 through 7.2.1, 7.0.0 through 7.0.5, 6.4 all versions, 6.0 all versions; FortiAP-U 7.0.0, 6.2.0 through 6.2.5, 6.0 all versions, 5.4 all versions may allow an authenticated attacker to read arbitrary files via specially crafted command arguments.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-792\", \"description\": \"Information disclosure\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2023-09-13T12:28:51.497Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-25608\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-24T20:00:10.726Z\", \"dateReserved\": \"2023-02-08T13:42:03.367Z\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2023-09-13T12:28:51.497Z\", \"assignerShortName\": \"fortinet\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…