CVE-2025-26409 (GCVE-0-2025-26409)
Vulnerability from cvelistv5
Published
2025-02-11 09:15
Modified
2025-03-17 16:40
CWE
  • CWE-1299 - Missing Protection Mechanism for Alternate Hardware Interface
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1.
Impacted products
Vendor Product Version
Wattsense Wattsense Bridge Version: 0   < 6.4.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26409",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T14:38:08.176508Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-1299",
                "description": "CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T16:40:45.172Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Wattsense Bridge",
          "vendor": "Wattsense",
          "versions": [
            {
              "lessThan": "6.4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Constantin Schieber-Kn\u00f6bl | SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Stefan Schweighofer | SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Steffen Robertz | SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\u0026nbsp;recent firmware versions BSP \u0026gt;= 6.4.1."
            }
          ],
          "value": "A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\u00a0recent firmware versions BSP \u003e= 6.4.1."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-180",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1299",
              "description": "CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191 On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-11T09:15:30.131Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/wattsense"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue is fixed in recent firmware versions BSP \u0026gt;= 6.4.1."
            }
          ],
          "value": "This issue is fixed in recent firmware versions BSP \u003e= 6.4.1."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Access to Bootloader and Shell Over Serial Interface",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-26409",
    "datePublished": "2025-02-11T09:15:30.131Z",
    "dateReserved": "2025-02-10T07:48:38.352Z",
    "dateUpdated": "2025-03-17T16:40:45.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-26409\",\"sourceIdentifier\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\",\"published\":\"2025-02-11T10:15:09.743\",\"lastModified\":\"2025-03-17T17:15:39.723\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\u00a0recent firmware versions BSP \u003e= 6.4.1.\"},{\"lang\":\"es\",\"value\":\"Se puede acceder a una interfaz serial con acceso f\u00edsico a la PCB de los dispositivos Wattsense Bridge. Despu\u00e9s de conectarse a la interfaz, es posible acceder al gestor de arranque, as\u00ed como a un mensaje de inicio de sesi\u00f3n de Linux. El acceso al gestor de arranque se puede utilizar para obtener un shell ra\u00edz en el dispositivo. Este problema se ha solucionado en las versiones de firmware recientes BSP \u0026gt;= 6.4.1.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1191\"},{\"lang\":\"en\",\"value\":\"CWE-1299\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1299\"}]}],\"references\":[{\"url\":\"https://r.sec-consult.com/wattsense\",\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\"},{\"url\":\"https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes\",\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-26409\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-11T14:38:08.176508Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1299\", \"description\": \"CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-11T14:38:50.624Z\"}}], \"cna\": {\"title\": \"Access to Bootloader and Shell Over Serial Interface\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Constantin Schieber-Kn\\u00f6bl | SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Stefan Schweighofer | SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Steffen Robertz | SEC Consult Vulnerability Lab\"}], \"impacts\": [{\"capecId\": \"CAPEC-180\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels\"}]}], \"affected\": [{\"vendor\": \"Wattsense\", \"product\": \"Wattsense Bridge\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"6.4.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"This issue is fixed in recent firmware versions BSP \u003e= 6.4.1.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"This issue is fixed in recent firmware versions BSP \u0026gt;= 6.4.1.\", \"base64\": false}]}], \"references\": [{\"url\": \"https://r.sec-consult.com/wattsense\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes\", \"tags\": [\"release-notes\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\\u00a0recent firmware versions BSP \u003e= 6.4.1.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\u0026nbsp;recent firmware versions BSP \u0026gt;= 6.4.1.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1299\", \"description\": \"CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1191\", \"description\": \"CWE-1191 On-Chip Debug and Test Interface With Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"551230f0-3615-47bd-b7cc-93e92e730bbf\", \"shortName\": \"SEC-VLab\", \"dateUpdated\": \"2025-02-11T09:15:30.131Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-26409\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-17T16:40:45.172Z\", \"dateReserved\": \"2025-02-10T07:48:38.352Z\", \"assignerOrgId\": \"551230f0-3615-47bd-b7cc-93e92e730bbf\", \"datePublished\": \"2025-02-11T09:15:30.131Z\", \"assignerShortName\": \"SEC-VLab\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…