CVE-2025-26410 (GCVE-0-2025-26410)
Vulnerability from cvelistv5
Published
2025-02-11 09:20
Modified
2025-03-18 18:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Summary
The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Wattsense | Wattsense Bridge |
Version: 0 < 6.4.1 |
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-26410", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-11T14:35:57.904824Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-18T18:27:29.653Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Wattsense Bridge", "vendor": "Wattsense", "versions": [ { "lessThan": "6.4.1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Constantin Schieber-Kn\u00f6bl | SEC Consult Vulnerability Lab" }, { "lang": "en", "type": "finder", "value": "Stefan Schweighofer | SEC Consult Vulnerability Lab" }, { "lang": "en", "type": "finder", "value": "Steffen Robertz | SEC Consult Vulnerability Lab" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u0026gt;= 6.4.1.\u003cbr\u003e" } ], "value": "The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u003e= 6.4.1." } ], "impacts": [ { "capecId": "CAPEC-653", "descriptions": [ { "lang": "en", "value": "CAPEC-653 Use of Known Operating System Credentials" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-11T09:20:22.708Z", "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf", "shortName": "SEC-VLab" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://r.sec-consult.com/wattsense" }, { "tags": [ "release-notes" ], "url": "https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "This issue is fixed in recent firmware versions BSP \u0026gt;= 6.4.1." } ], "value": "This issue is fixed in recent firmware versions BSP \u003e= 6.4.1." } ], "source": { "discovery": "EXTERNAL" }, "title": "Weak Hard-coded Credentials", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf", "assignerShortName": "SEC-VLab", "cveId": "CVE-2025-26410", "datePublished": "2025-02-11T09:20:22.708Z", "dateReserved": "2025-02-10T07:48:38.352Z", "dateUpdated": "2025-03-18T18:27:29.653Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-26410\",\"sourceIdentifier\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\",\"published\":\"2025-02-11T10:15:09.863\",\"lastModified\":\"2025-03-18T19:15:50.450\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u003e= 6.4.1.\"},{\"lang\":\"es\",\"value\":\"El firmware de todos los dispositivos Wattsense Bridge contiene las mismas credenciales de usuario y ra\u00edz codificadas. La contrase\u00f1a de usuario se puede recuperar f\u00e1cilmente mediante intentos de descifrado de contrase\u00f1as. Las credenciales recuperadas se pueden utilizar para iniciar sesi\u00f3n en el dispositivo a trav\u00e9s del shell de inicio de sesi\u00f3n que est\u00e1 expuesto por la interfaz serial. El usuario de puerta trasera se ha eliminado en el firmware BSP \u0026gt;= 6.4.1.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"references\":[{\"url\":\"https://r.sec-consult.com/wattsense\",\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\"},{\"url\":\"https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes\",\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-26410\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-11T14:35:57.904824Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-11T14:36:43.042Z\"}}], \"cna\": {\"title\": \"Weak Hard-coded Credentials\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Constantin Schieber-Kn\\u00f6bl | SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Stefan Schweighofer | SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Steffen Robertz | SEC Consult Vulnerability Lab\"}], \"impacts\": [{\"capecId\": \"CAPEC-653\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-653 Use of Known Operating System Credentials\"}]}], \"affected\": [{\"vendor\": \"Wattsense\", \"product\": \"Wattsense Bridge\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"6.4.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"This issue is fixed in recent firmware versions BSP \u003e= 6.4.1.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"This issue is fixed in recent firmware versions BSP \u0026gt;= 6.4.1.\", \"base64\": false}]}], \"references\": [{\"url\": \"https://r.sec-consult.com/wattsense\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes\", \"tags\": [\"release-notes\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u003e= 6.4.1.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP \u0026gt;= 6.4.1.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-798\", \"description\": \"CWE-798 Use of Hard-coded Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"551230f0-3615-47bd-b7cc-93e92e730bbf\", \"shortName\": \"SEC-VLab\", \"dateUpdated\": \"2025-02-11T09:20:22.708Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-26410\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-18T18:27:29.653Z\", \"dateReserved\": \"2025-02-10T07:48:38.352Z\", \"assignerOrgId\": \"551230f0-3615-47bd-b7cc-93e92e730bbf\", \"datePublished\": \"2025-02-11T09:20:22.708Z\", \"assignerShortName\": \"SEC-VLab\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…