fkie_cve-2018-10626
Vulnerability from fkie_nvd
Published
2018-08-10 18:29
Modified
2025-05-22 16:15
Severity ?
Summary
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/105042 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-8-7-18.html | ||
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105042 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4008DB3-E151-41BA-A308-7BE733268845", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:*", "matchCriteriaId": "60267DCC-89D0-48E3-B6EB-9AD60DC1F16F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8AACDB33-1EC3-44E1-8C1C-38C766E85F85", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:*", "matchCriteriaId": "BCDA4070-6CDD-42CA-A4A8-DA6B0E98C64D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Medtronic MyCareLink Patient Monitor\u2019s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network." }, { "lang": "es", "value": "Se ha descubierto una vulnerabilidad en todas las versiones de Medtronic MyCareLink Patient Monitor 24950 y 24952. El servicio de actualizaci\u00f3n de los productos afectados no verifica lo suficiente la autenticidad de los datos subidos. Un atacante que obtenga las credenciales por producto del monitor y empareje informaci\u00f3n del dispositivo card\u00edaco implantable podr\u00eda subir datos inv\u00e1lidos a la red de Medtronic CareLink." } ], "id": "CVE-2018-10626", "lastModified": "2025-05-22T16:15:51.107", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:M/Au:S/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 4.4, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 1.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 2.7, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }, "published": "2018-08-10T18:29:00.353", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105042" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-8-7-18.html" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105042" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-345" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-345" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…