fkie_cve-2021-37203
Vulnerability from fkie_nvd
Published
2021-09-14 11:15
Modified
2024-11-21 06:14
Severity ?
Summary
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.
References
▶ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | nx_1980 | * | |
siemens | solid_edge | * | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*", "matchCriteriaId": "D3A09766-0171-4DDA-9BF9-D379DA134571", "versionEndExcluding": "1984", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "matchCriteriaId": "576A303A-66CA-4694-AA54-9EB0137C24F1", "versionEndExcluding": "se2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "matchCriteriaId": "82090774-D894-41C8-82F1-A48A8707E9BB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*", "matchCriteriaId": "BD346D22-9B5D-4A50-94E2-1F5C8D391EC3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*", "matchCriteriaId": "1466AEE0-4A5C-4E2D-80B8-43680F60FC31", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*", "matchCriteriaId": "A4173D09-C317-45FF-ABA4-39E5592862F8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de l\u00edmites al analizar los archivos IFC suministrados por el usuario, lo que podr\u00eda dar lugar a una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Esto podr\u00eda permitir a un atacante causar una condici\u00f3n de denegaci\u00f3n de servicio o leer informaci\u00f3n sensible de ubicaciones de memoria" } ], "id": "CVE-2021-37203", "lastModified": "2024-11-21T06:14:51.227", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-09-14T11:15:26.473", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.