fkie_cve-2021-37203
Vulnerability from fkie_nvd
Published
2021-09-14 11:15
Modified
2024-11-21 06:14
Summary
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A09766-0171-4DDA-9BF9-D379DA134571",
              "versionEndExcluding": "1984",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "576A303A-66CA-4694-AA54-9EB0137C24F1",
              "versionEndExcluding": "se2021",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
              "matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
              "matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
              "matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
              "matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*",
              "matchCriteriaId": "82090774-D894-41C8-82F1-A48A8707E9BB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*",
              "matchCriteriaId": "BD346D22-9B5D-4A50-94E2-1F5C8D391EC3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*",
              "matchCriteriaId": "1466AEE0-4A5C-4E2D-80B8-43680F60FC31",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*",
              "matchCriteriaId": "A4173D09-C317-45FF-ABA4-39E5592862F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de l\u00edmites al analizar los archivos IFC suministrados por el usuario, lo que podr\u00eda dar lugar a una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Esto podr\u00eda permitir a un atacante causar una condici\u00f3n de denegaci\u00f3n de servicio o leer informaci\u00f3n sensible de ubicaciones de memoria"
    }
  ],
  "id": "CVE-2021-37203",
  "lastModified": "2024-11-21T06:14:51.227",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-09-14T11:15:26.473",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…