gsd-2020-3446
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2020-3446", "description": "A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges.", "id": "GSD-2020-3446" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-3446" ], "details": "A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges.", "id": "GSD-2020-3446", "modified": "2023-12-13T01:22:09.460241Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-08-19T16:00:00", "ID": "CVE-2020-3446", "STATE": "PUBLIC", "TITLE": "Cisco vWAAS for Cisco ENCS 5400-W Series and CSP 5000-W Series Default Credentials Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Wide Area Application Services (WAAS) ", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges." } ] }, "exploit": [ { "lang": "eng", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. " } ], "impact": { "cvss": { "baseScore": "9.8", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H ", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "20200819 Cisco vWAAS for Cisco ENCS 5400-W Series and CSP 5000-W Series Default Credentials Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-waas-encsw-cspw-cred-hZzL29A7" } ] }, "source": { "advisory": "cisco-sa-waas-encsw-cspw-cred-hZzL29A7", "defect": [ [ "CSCvg93455", "CSCvr36481" ] ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:encs_5406-w_firmware:6.4\\(1\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:encs_5406-w_firmware:6.4\\(3d\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:encs_5406-w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:encs_5408-w_firmware:6.4\\(1\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:encs_5408-w_firmware:6.4\\(3d\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:encs_5408-w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:encs_5412-w_firmware:6.4\\(1\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:encs_5412-w_firmware:6.4\\(3d\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:encs_5412-w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:csp_5228-w_firmware:6.4\\(1\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:csp_5228-w_firmware:6.4\\(3d\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:csp_5228-w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:cisco:csp_5436-w_firmware:6.4\\(1\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:cisco:csp_5436-w_firmware:6.4\\(3d\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:csp_5436-w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2020-3446" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "20200819 Cisco vWAAS for Cisco ENCS 5400-W Series and CSP 5000-W Series Default Credentials Vulnerability", "refsource": "CISCO", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-waas-encsw-cspw-cred-hZzL29A7" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2020-09-03T18:54Z", "publishedDate": "2020-08-26T17:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…