The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information (ePHI), protected health information (PHI) or personally identifiable information (PII) is stored in the pump.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-43557", "id": "GSD-2022-43557" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-43557" ], "details": "The BD BodyGuard\u2122 infusion pumps specified allow for access through the RS-232\u00a0(serial) port interface. If exploited, threat actors with physical access, specialized equipment and\u00a0knowledge may be able to configure or disable the pump. No electronic protected health information\u00a0(ePHI), protected health information (PHI) or personally identifiable information (PII) is stored in the\u00a0pump.", "id": "GSD-2022-43557", "modified": "2023-12-13T01:19:31.755729Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@bd.com", "ID": "CVE-2022-43557", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "BodyGuard\u2122 Pump", "version": { "version_data": [ { "version_affected": "=", "version_value": "BD BodyGuard\u2122 " }, { "version_affected": "=", "version_value": "CME BodyGuard\u2122 323 (2nd Edition)" }, { "version_affected": "=", "version_value": "CME BodyGuard\u2122 323 Color Vision (2nd Edition)" }, { "version_affected": "=", "version_value": "CME BodyGuard\u2122 323 Color Vision (3rd Edition)" }, { "version_affected": "=", "version_value": "CME BodyGuard\u2122 Twins (2nd Edition)" } ] } } ] }, "vendor_name": "Becton, Dickinson and Company (BD)" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The BD BodyGuard\u2122 infusion pumps specified allow for access through the RS-232\u00a0(serial) port interface. If exploited, threat actors with physical access, specialized equipment and\u00a0knowledge may be able to configure or disable the pump. No electronic protected health information\u00a0(ePHI), protected health information (PHI) or personally identifiable information (PII) is stored in the\u00a0pump." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "HIGH", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-1299", "lang": "eng", "value": "CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability", "refsource": "MISC", "url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability" } ] }, "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "BD recommends the following mitigations and compensating controls to reduce risk associated with this\u003cbr\u003evulnerability:\u003cbr\u003e\u2022 Ensure physical access controls are in place and only authorized end-users have access to\u003cbr\u003eBD BodyGuard\u2122 pumps.\u003cbr\u003e\u2022 Ensure that only BD-approved equipment is connected to the RS-232 interface of the affected pumps.\u003cbr\u003e\u2022 Ensure that no equipment is connected to the RS-232 interface when the affected pumps are delivering\u003cbr\u003einfusions.\u003cbr\u003e\u2022 Protect connected computer systems with BodyComm\u2122 software with standard security measures.\u003cbr\u003e" } ], "value": "BD recommends the following mitigations and compensating controls to reduce risk associated with this\nvulnerability:\n\u2022 Ensure physical access controls are in place and only authorized end-users have access to\nBD BodyGuard\u2122 pumps.\n\u2022 Ensure that only BD-approved equipment is connected to the RS-232 interface of the affected pumps.\n\u2022 Ensure that no equipment is connected to the RS-232 interface when the affected pumps are delivering\ninfusions.\n\u2022 Protect connected computer systems with BodyComm\u2122 software with standard security measures.\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_999-603_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_999-603:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_duo_999-903_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_duo_999-903:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_epidural_999-683_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_epidural_999-683:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_pain_manager_999-803_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_pain_manager_999-803:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_t_999-103_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_t_999-103:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_323_colorvision_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_323_colorvision:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:bd:bodyguard_121_twins_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:bd:bodyguard_121_twins:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@bd.com", "ID": "CVE-2022-43557" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The BD BodyGuard\u2122 infusion pumps specified allow for access through the RS-232\u00a0(serial) port interface. If exploited, threat actors with physical access, specialized equipment and\u00a0knowledge may be able to configure or disable the pump. No electronic protected health information\u00a0(ePHI), protected health information (PHI) or personally identifiable information (PII) is stored in the\u00a0pump." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-287" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability", "refsource": "MISC", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-bodyguard-pumps-rs-232-interface-vulnerability" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 0.5, "impactScore": 4.7 } }, "lastModifiedDate": "2023-10-27T21:15Z", "publishedDate": "2022-12-05T22:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…