Vulnerabilites related to Siemens - APOGEE PXC Compact (BACnet)
CVE-2020-27737 (GCVE-0-2020-27737)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
CWE
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition  or leak the memory past the allocated structure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:04.435Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27737",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27736 (GCVE-0-2020-27736)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
CWE
  • CWE-170 - Improper Null Termination
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.573Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:03.377Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27736",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25677 (GCVE-0-2021-25677)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-03 20:11
CWE
  • CWE-330 - Use of Insufficiently Random Values
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:28.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V0.5.0.0 \u003c V1.0.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003e= V0.5.0.0 \u003c V1.0.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:07.625Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-25677",
    "datePublished": "2021-04-22T20:42:21",
    "dateReserved": "2021-01-21T00:00:00",
    "dateUpdated": "2024-08-03T20:11:28.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-15795 (GCVE-0-2020-15795)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 13:30
CWE
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:30:21.684Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:01.115Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-15795",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-07-15T00:00:00",
    "dateUpdated": "2024-08-04T13:30:21.684Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31887 (GCVE-0-2021-31887)
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity ?
CWE
  • CWE-170 - Improper Null Termination
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MBC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXM20-E Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Nucleus NET Version: All versions
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: All versions < V2017.02.4
Create a notification for this product.
   Siemens Nucleus Source Code Version: All versions
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.650Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31887",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cPWD/XPWD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31887",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.650Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31884 (GCVE-0-2021-31884)
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity ?
CWE
  • CWE-170 - Improper Null Termination
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MBC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens Capital VSTAR Version: All versions with enabled Ethernet options
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXM20-E Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Nucleus NET Version: All versions
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: All versions < V2017.02.4
Create a notification for this product.
   Siemens Nucleus Source Code Version: All versions
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.775Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Capital VSTAR",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions with enabled Ethernet options"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:33",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31884",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Capital VSTAR",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions with enabled Ethernet options"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). The DHCP client application assumes that the data supplied with the \u201cHostname\u201d DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31884",
    "datePublished": "2021-11-09T11:31:57",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31885 (GCVE-0-2021-31885)
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity ?
CWE
  • CWE-805 - Buffer Access with Incorrect Length Value
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MBC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXM20-E Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Nucleus NET Version: All versions
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: All versions < V2017.02.4
Create a notification for this product.
   Siemens Nucleus ReadyStart V4 Version: All versions < V4.1.1
Create a notification for this product.
   Siemens Nucleus Source Code Version: All versions
Create a notification for this product.
   Siemens PLUSCONTROL 1st Gen Version: All versions
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.607Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-805",
              "description": "CWE-805: Buffer Access with Incorrect Length Value",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:34",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31885",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PLUSCONTROL 1st Gen",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-805: Buffer Access with Incorrect Length Value"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31885",
    "datePublished": "2021-11-09T11:31:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-28388 (GCVE-0-2020-28388)
Vulnerability from cvelistv5
Published
2021-02-09 00:00
Modified
2024-08-04 16:33
CWE
  • CWE-342 - Predictable Exact Value from Previous Values
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:58.999Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2012.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus ReadyStart V3 (All versions \u003c V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-342",
              "description": "CWE-342: Predictable Exact Value from Previous Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:06.562Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28388",
    "datePublished": "2021-02-09T00:00:00",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:58.999Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31886 (GCVE-0-2021-31886)
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2024-08-03 23:10
Severity ?
CWE
  • CWE-170 - Improper Null Termination
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MBC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXM20-E Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Nucleus NET Version: All versions
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: All versions < V2017.02.4
Create a notification for this product.
   Siemens Nucleus Source Code Version: All versions
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.838Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:35",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31886",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cUSER\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31886",
    "datePublished": "2021-11-09T11:31:59",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.838Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-45937 (GCVE-0-2022-45937)
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2025-04-21 13:43
CWE
  • CWE-284 - Improper Access Control
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-45937",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:21:23.901858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:43:23.146Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:12.585Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-45937",
    "datePublished": "2022-12-13T00:00:00.000Z",
    "dateReserved": "2022-11-28T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:43:23.146Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27738 (GCVE-0-2020-27738)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
CWE
  • CWE-788 - Access of Memory Location After End of Buffer
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.774Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:05.489Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27738",
    "datePublished": "2021-04-22T20:42:20",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.774Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38371 (GCVE-0-2022-38371)
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2025-05-13 09:38
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MBC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: 0   < V3.5.7
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: 0   < V2.8.21
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: 0   < V3.5.7
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: 0   < V2.8.21
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC00-U Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC128-U Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXC64-U Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Desigo PXM20-E Version: V2.3   < V6.30.37
Create a notification for this product.
   Siemens Nucleus NET for Nucleus PLUS V1 Version: All versions < V5.2a
Create a notification for this product.
   Siemens Nucleus NET for Nucleus PLUS V2 Version: All versions < V5.4
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 V2012 Version: All versions < V2012.08.1
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 V2017 Version: All versions < V2017.02.4
Create a notification for this product.
   Siemens Nucleus Source Code Version: 0   < *
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: 0   < V3.5.7
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: 0   < V3.5.7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.448Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313313.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-935500.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-935500.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-313313.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38371",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T18:15:00.675232Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-17T13:53:27.567Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.21",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.21",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.30.37",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET for Nucleus PLUS V1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2a"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET for Nucleus PLUS V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3 V2012",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2012.08.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3 V2017",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.21), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.21), Desigo PXC00-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC00-U (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC001-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC100-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC12-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC128-U (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC200-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC22-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC22.1-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC36.1-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC50-E.D (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXC64-U (All versions \u003e= V2.3 \u003c V6.30.37), Desigo PXM20-E (All versions \u003e= V2.3 \u003c V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions \u003c V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions \u003c V5.4), Nucleus ReadyStart V3 V2012 (All versions \u003c V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions \u003c V3.5.7), TALON TC Modular (BACnet) (All versions \u003c V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-13T09:38:10.488Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313313.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-935500.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-935500.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-313313.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-38371",
    "datePublished": "2022-10-11T00:00:00",
    "dateReserved": "2022-08-16T00:00:00",
    "dateUpdated": "2025-05-13T09:38:10.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-13939 (GCVE-0-2019-13939)
Vulnerability from cvelistv5
Published
2020-01-16 15:35
Modified
2025-06-10 15:17
CWE
  • CWE-20 - Improper Input Validation
Summary
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.
Impacted products
Vendor Product Version
Siemens APOGEE MEC/MBC/PXC (P2) Version: All versions < V2.8.2
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: V2.8.2   < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: V2.8.2   < V2.8.19
Create a notification for this product.
   Siemens Capital Embedded AR Classic 431-422 Version: 0   < *
Create a notification for this product.
   Siemens Capital Embedded AR Classic R20-11 Version: 0   < V2303
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXM20-E Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Nucleus NET Version: 0   < *
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: 0   < V2017.02.3
Create a notification for this product.
   Siemens Nucleus Source Code Version: 0   < *
Create a notification for this product.
   Siemens SIMOTICS CONNECT 400 Version: All versions < V0.3.0.330
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:43.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC/MBC/PXC (P2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.19",
              "status": "affected",
              "version": "V2.8.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.19",
              "status": "affected",
              "version": "V2.8.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2017.02.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.3.0.330"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions \u003c V2.8.2), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Desigo PXC00-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC00-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC001-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC100-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC12-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC128-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC200-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC36.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC50-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC64-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXM20-E (All versions \u003e= V2.3 \u003c V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.3.0.330), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T15:17:09.328Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13939",
    "datePublished": "2020-01-16T15:35:24",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2025-06-10T15:17:09.328Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27009 (GCVE-0-2020-27009)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:03
CWE
  • CWE-823 - Use of Out-of-range Pointer Offset
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:03:23.236Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-823",
              "description": "CWE-823: Use of Out-of-range Pointer Offset",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:02.298Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27009",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-12T00:00:00",
    "dateUpdated": "2024-08-04T16:03:23.236Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27391 (GCVE-0-2021-27391)
Vulnerability from cvelistv5
Published
2021-09-14 10:47
Modified
2025-04-23 19:28
Severity ?
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.974Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2021-27391",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T13:27:50.374532Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T19:28:38.162Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.6.3"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.6.3"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:31.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27391",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.6.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27391",
    "datePublished": "2021-09-14T10:47:31.000Z",
    "dateReserved": "2021-02-18T00:00:00.000Z",
    "dateUpdated": "2025-04-23T19:28:38.162Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31888 (GCVE-0-2021-31888)
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-03 23:10
Severity ?
CWE
  • CWE-170 - Improper Null Termination
Summary
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)
Impacted products
Vendor Product Version
Siemens APOGEE MBC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MBC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (BACnet) Version: All versions
Create a notification for this product.
   Siemens APOGEE MEC (PPC) (P2 Ethernet) Version: All versions
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: All versions < V2.8.19
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Desigo PXM20-E Version: All versions >= V2.3 and < V6.30.016
Create a notification for this product.
   Siemens Nucleus NET Version: All versions
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: All versions < V2017.02.4
Create a notification for this product.
   Siemens Nucleus Source Code Version: All versions
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: All versions < V3.5.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE MBC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MBC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE MEC (PPC) (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.19"
            }
          ]
        },
        {
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3 and \u003c V6.30.016"
            }
          ]
        },
        {
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        },
        {
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31888",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "APOGEE MBC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Compact (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APOGEE PXC Modular (P2 Ethernet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC00-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC001-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC100-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC12-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC128-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC200-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC22.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC36.1-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC50-E.D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXC64-U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Desigo PXM20-E",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus NET",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus ReadyStart V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2017.02.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nucleus Source Code",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Compact (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TALON TC Modular (BACnet)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). FTP server does not properly validate the length of the \u201cMKD/XMKD\u201d command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-170: Improper Null Termination"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31888",
    "datePublished": "2021-11-09T11:32:00",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}