Vulnerabilites related to Siemens - SIMOTICS CONNECT 400
CVE-2021-31889 (GCVE-0-2021-31889)
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2025-03-11 09:47
CWE
  • CWE-191 - Integer Underflow (Wrap or Wraparound)
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-191",
              "description": "CWE-191: Integer Underflow (Wrap or Wraparound)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:45.226Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31889",
    "datePublished": "2021-11-09T11:32:01",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:45.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27737 (GCVE-0-2020-27737)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
CWE
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition  or leak the memory past the allocated structure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:04.435Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27737",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31890 (GCVE-0-2021-31890)
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2025-03-11 09:47
CWE
  • CWE-240 - Improper Handling of Inconsistent Structural Elements
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.798Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-240",
              "description": "CWE-240: Improper Handling of Inconsistent Structural Elements",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:46.741Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31890",
    "datePublished": "2021-11-09T11:32:02",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2025-03-11T09:47:46.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27736 (GCVE-0-2020-27736)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
CWE
  • CWE-170 - Improper Null Termination
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.573Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-170",
              "description": "CWE-170: Improper Null Termination",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:03.377Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27736",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25677 (GCVE-0-2021-25677)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-03 20:11
CWE
  • CWE-330 - Use of Insufficiently Random Values
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:28.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V0.5.0.0 \u003c V1.0.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003e= V0.5.0.0 \u003c V1.0.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:07.625Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-25677",
    "datePublished": "2021-04-22T20:42:21",
    "dateReserved": "2021-01-21T00:00:00",
    "dateUpdated": "2024-08-03T20:11:28.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31344 (GCVE-0-2021-31344)
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2025-03-11 09:47
CWE
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843: Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:36.591Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31344",
    "datePublished": "2021-11-09T11:31:51",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:36.591Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31346 (GCVE-0-2021-31346)
Vulnerability from cvelistv5
Published
2021-11-09 11:31
Modified
2025-03-11 09:47
CWE
  • CWE-1284 - Improper Validation of Specified Quantity in Input
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:55:53.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), SIMOTICS CONNECT 400 (All versions \u003c V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:39.488Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-845392.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31346",
    "datePublished": "2021-11-09T11:31:53",
    "dateReserved": "2021-04-15T00:00:00",
    "dateUpdated": "2025-03-11T09:47:39.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-27738 (GCVE-0-2020-27738)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:18
CWE
  • CWE-788 - Access of Memory Location After End of Buffer
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:18:45.774Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2017.02.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Versions including affected DNS modules"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-788",
              "description": "CWE-788: Access of Memory Location After End of Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:05.489Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-27738",
    "datePublished": "2021-04-22T20:42:20",
    "dateReserved": "2020-10-26T00:00:00",
    "dateUpdated": "2024-08-04T16:18:45.774Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-13939 (GCVE-0-2019-13939)
Vulnerability from cvelistv5
Published
2020-01-16 15:35
Modified
2025-06-10 15:17
CWE
  • CWE-20 - Improper Input Validation
Summary
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.
Impacted products
Vendor Product Version
Siemens APOGEE MEC/MBC/PXC (P2) Version: All versions < V2.8.2
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: V2.8.2   < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: V2.8.2   < V2.8.19
Create a notification for this product.
   Siemens Capital Embedded AR Classic 431-422 Version: 0   < *
Create a notification for this product.
   Siemens Capital Embedded AR Classic R20-11 Version: 0   < V2303
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXM20-E Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Nucleus NET Version: 0   < *
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: 0   < V2017.02.3
Create a notification for this product.
   Siemens Nucleus Source Code Version: 0   < *
Create a notification for this product.
   Siemens SIMOTICS CONNECT 400 Version: All versions < V0.3.0.330
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:43.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC/MBC/PXC (P2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.19",
              "status": "affected",
              "version": "V2.8.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.19",
              "status": "affected",
              "version": "V2.8.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2017.02.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.3.0.330"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions \u003c V2.8.2), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Desigo PXC00-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC00-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC001-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC100-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC12-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC128-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC200-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC36.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC50-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC64-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXM20-E (All versions \u003e= V2.3 \u003c V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.3.0.330), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T15:17:09.328Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13939",
    "datePublished": "2020-01-16T15:35:24",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2025-06-10T15:17:09.328Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}